A technique to reduce low dose region for craniospinal irradiation (CSI) with RapidArc and its dosimetric comparison with 3D conformal technique (3DCRT)

被引:4
|
作者
Srivastava, Roopam [1 ]
Saini, Gagan [2 ]
Sharma, Pramod Kumar [1 ]
Chomal, Manish [2 ]
Aagarwal, Anchal [3 ]
Nangia, Sapna [3 ]
Garg, Madhur [4 ]
机构
[1] Fortis Hosp, Int Oncol Ctr, Dept Med Phys & Radiat Safety, Noida 201301, Uttar Pradesh, India
[2] Fortis Hosp, Int Oncol Ctr, Dept Radiat Oncol, Noida 201301, Uttar Pradesh, India
[3] Indraprastha Apollo Hosp, Dept Radiat Oncol, New Delhi, India
[4] Montefiore Canc Ctr, Dept Radiat Oncol, New York, NY USA
关键词
Avoidance sector technique in RapidArc; craniospinal irradiation; RapidArc; V5 in lung; MODULATED ARC THERAPY; RADIOTHERAPY;
D O I
10.4103/0973-1482.144556
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We proposed a method to reduce the volume of normal tissues irradiated by low doses in patients receiving CSI with RapidArc (RA) using Avoidance-Sector technique (RA+AS) and to compare its dosimetric implications with RA using full-arc (RA+FA) and 3D conformal technique (3DCRT). Four patients of CSI were retrospectively planned with 3DCRT, RA+FA, and RA+AS. Conformity-Index (CI), Homogeneity-Index (HI), and Paddick Gradient-Index (GI) were calculated. Quantitative evaluation was done using DVH analysis for PTVs and OARs. When compared with 3DCRT, GI, CI, and HI were favorable to RA based techniques. In comparison with 3DCRT the doses to OARs were lower with RA+AS with the difference being statistically significant in most instances. RA+AS significantly decreases the dose to OARs and their volumes receiving low doses in comparison with RA+FA and 3DCRT.
引用
收藏
页码:488 / 491
页数:4
相关论文
共 50 条
  • [1] DOSIMETRIC COMPARISON OF TOMOTHERAPY IMRT AND 3DCRT FOR CRANIOSPINAL IRRADIATION
    Bandurska, A.
    Piotrowski, T.
    Skrobala, A.
    Ryczkowski, A.
    Kazmierska, J.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S259 - S259
  • [2] A dosimetric comparison of 3-dimentional conformal radiotherapy (3DCRT) and helical tomotherapy for craniospinal irradiation
    Swanson, E
    Jursinic, P
    Herman, J
    Lee, W
    Firat, SY
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S265 - S265
  • [3] PROCEDURE FOR CRANIOSPINAL AXIS RADIOTHERAPY (CSI) TECHNIQUE IN CONFORMAL (3DCRT) WITH HALFBEAM AND SINGLE JUNCTION CABINET
    Scoccianti, S.
    Agresti, B.
    Talamonti, C.
    Simontacchi, G.
    Mangoni, M.
    Paiar, F.
    Cipressi, S.
    Bucciolini, M.
    Biti, G. P.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2010, 95 (07): : S23 - S24
  • [4] CRANIOSPINAL IRRADIATION (CSI) FOR MEDULLOBLASTOMA: FROM 3D CONFORMAL RADIOTHERAPY (3DCRT) TO VOLUMETRIC MODULATED ARC THERAPY (VMAT). ARE WE READY FOR THE CHANGE?
    Gandola, Lorenza
    Meroni, Silvia
    Giandini, Tommaso
    Pecori, Emilia
    Diletto, Barbara
    Cavatorta, Claudia
    Biassoni, Veronica
    Schiavello, Elisabetta
    Spreafico, Filippo
    Massimino, Maura
    Pignoli, Emanuele
    NEURO-ONCOLOGY, 2016, 18 : 162 - 162
  • [5] Prospective study on dosimetric comparison of helical tomotherapy and 3DCRT for craniospinal irradiation - A single institution experience
    Bandurska-Luque, Anna
    Piotrowski, Tomasz
    Skrobala, Agnieszka
    Ryczkowski, Adam
    Adamska, Krystyna
    Kazmierska, Joanna
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (02) : 145 - 152
  • [6] Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning
    Jiang, R.
    Zhan, L.
    Osei, E.
    MEDICAL PHYSICS, 2015, 42 (06) : 3459 - 3459
  • [7] Moving from 2D to 3D conformal radiotherapy (3DCRT) in locally advanced head and neck cancer: A dosimetric comparison
    Billan, S. G.
    Bakouche, V.
    Nevelsky, A.
    Abdah-Bortnyak, R.
    Uziel, R.
    Rawashdeh, F.
    Gez, E.
    Epelbaum, R.
    Kuten, A.
    JOURNAL OF CLINICAL ONCOLOGY, 2007, 25 (18)
  • [8] Clinical implementation of tangential field intensity modulated radiation therapy (IMRT) using sliding window technique and dosimetric comparison with 3d conformal therapy (3dcrt) in breast cancer
    Selvaraj, Raj N.
    Beriwal, Sushil
    Pourarian, Roya J.
    Lalonde, Ron J.
    Chen, Alex
    Mehta, Kiran
    Brunner, Gwendolyn
    Wagner, Kathy A.
    Yue, Ning J.
    Huq, Saiful M.
    Heron, Dwight E.
    MEDICAL DOSIMETRY, 2007, 32 (04) : 299 - 304
  • [9] Comparison of RapidArc Volumetric Modulated Arc Therapy, Helical Tomotherapy, and 3D Conformal Radiotherapy for Pediatric Craniospinal Irradiation
    Patel, S.
    Warkentin, H.
    Powell, K.
    Syme, A.
    Warkentin, B.
    Fallone, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S591 - S591
  • [10] A dosimetric comparison of 3 types of breast treatment plans. 3D conformal, RapidArc and IMRT
    Pella, S.
    Dumitru, N.
    Pudasani, M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S995 - S995