Towards conductive-gel-free electrodes: Understanding the wet electrode, semi-dry electrode and dry electrode-skin interface impedance using electrochemical impedance spectroscopy fitting

被引:136
|
作者
Li, Guangli [1 ,2 ]
Wang, Sizhe [2 ]
Duan, Yanwen Y. [2 ]
机构
[1] Hunan Univ Technol, Coll Life Sci & Chem, Hunan Key Lab Biomed Nanomat & Devices, Zhuzhou 412007, Peoples R China
[2] Wuhan Univ, Coll Chem & Mol Sci, Wuhan 430072, Peoples R China
关键词
Electrochemical impedance spectroscopy; Dry electrode; Semi-dry electrode; Wet electrode; Equivalent circuit; Electrode-Skin impedance; ELECTROENCEPHALOGRAPHY SIGNALS; EEG; FABRICATION; COATINGS; SYSTEM;
D O I
10.1016/j.snb.2018.08.155
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrode-scalp impedance of six subjects is studied by electrochemical impedance spectroscopy using three representative electrodes, namely wet electrodes, semi-dry electrodes, and dry electrodes. With the analysis of proposed equivalent models and area-normalized impedance (kQ cm(2)), the specific electrode double layer resistances are 530 Q cm(2) for all electrodes, their specific contact resistances R are 80 Q cm(2), 114 Q cm(2) and 20,077 Q cm(2), and their specific skin resistances 13., are 867 Q cm(2), 1730 Q cm(2) and 46,145 Q cm(2) for these three representative electrodes respectively. When pressure was applied on dry electrodes, R reduced by 47% and Rs reduced by 81%. When pressure was applied on semi-dry electrodes, Rs reduced by 50% (R is not applicable for semi-dry electrodes). After application of scalp abrasion for dry electrodes, R reduced by 36% and Rs reduced by 82%. After application of scalp abrasion for semi-dry electrodes, Rs reduced by 64%. Seeking novel interface materials may break through the bottleneck for dry electrodes development in terms of integrated materials, mechanical support and electronic circuitry, while semi-dry electrodes have much development space to meet a balance of quick setup, comfortable wear, and satisfactory signal quality in many medical and out-clinic applications.
引用
收藏
页码:250 / 260
页数:11
相关论文
共 28 条
  • [1] Towards gel-free electrodes: A systematic study of electrode-skin impedance
    Li, Guangli
    Wang, Sizhe
    Duan, Yanwen Y.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 1244 - 1255
  • [2] A flexible, stable, semi-dry electrode with low impedance for electroencephalography recording
    Zhu, Yiyan
    Bayin, Caicaike
    Li, Hongjie
    Shu, Xiaokang
    Deng, Jiangnan
    Yuan, Haowen
    Shen, Huyan
    Liang, Zhou
    Li, Yao
    RSC ADVANCES, 2024, 14 (46) : 34415 - 34427
  • [3] Time based measurement of the impedance of the skin-electrode interface for dry electrode ECG recording
    Dozio, Roberta
    Baba, Adeshina
    Assambo, Cedric
    Burke, Martin J.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 5001 - 5004
  • [4] NOVEL DRY STIMULATING ELECTRODE: COMPARISON OF SURFACE ELECTRODES USING IMPEDANCE SPECTROSCOPY.
    Kosierkiewicz, T. A.
    MUSCLE & NERVE, 2012, 46 (04) : 629 - 629
  • [5] Study into the repeatability of the electrode-skin interface utilizing electrodes commonly used in Electirical Impedance Tomography
    Wang, W.
    Wang, L.
    Qiao, G.
    Prickett, P.
    Bramer, B.
    Tunstall, B.
    Ai-Akaidi, M.
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 336 - +
  • [6] Changes in impedance at the electrode-skin interface of surface EMG electrodes during long-term EMG recordings
    Hewson, DJ
    Duchêne, J
    Hogrel, JY
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 3345 - 3348
  • [7] Performance assessment of dry electrodes for wearable long term cardiac rhythm monitoring: skin-electrode impedance spectroscopy
    Bosnjak, Antonio
    Kennedy, Alan
    Linares, Pedro
    Borges, Maira
    McLaughlin, James
    Escalona, Omar J.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1861 - 1864
  • [8] Characteristics of skin impedance for biological active points using dry electrode measurement system
    Kim, Min Soo
    Kwon, In Su
    Kim, Hag Dong
    Lim, Geunbae
    13TH INTERNATIONAL CONFERENCE ON ELECTRICAL BIOIMPEDANCE AND THE 8TH CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY 2007, 2007, 17 : 177 - +
  • [9] Bio-potential noise of dry printed electrodes: physiology versus the skin-electrode impedance
    Arche-Nunez, Ana
    Krebsbach, Peter
    Levit, Bara
    Possti, Daniel
    Gerston, Aaron
    Knoll, Thorsten
    Velten, Thomas
    Bar-Haim, Chen
    Oz, Shani
    Klorfeld-Auslender, Shira
    Hernandez-Sosa, Gerardo
    Mirelman, Anat
    Hanein, Yael
    PHYSIOLOGICAL MEASUREMENT, 2023, 44 (09)
  • [10] Evolution in impedance at the electrode-skin interface of two types of surface EMG electrodes during long-term recordings
    Hewson, DJ
    Hogrel, JY
    Langeron, Y
    Duchêne, J
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2003, 13 (03) : 273 - 279