In vivo fracture resistance of implant-supported all-ceramic restorations

被引:175
|
作者
Yildirim, M [1 ]
Fischer, H [1 ]
Marx, R [1 ]
Edelhoff, D [1 ]
机构
[1] Univ Aachen, Dept Prosthodont, D-5100 Aachen, Germany
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2003年 / 90卷 / 04期
关键词
D O I
10.1016/S0022-3913(03)00514-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Because of their specific mechanical properties, all-ceramic restorations demonstrate a lower fracture resistance than ceramic restorations supported by metal substructures. However, advances have been made in the fabrication of high-strength all-ceramic abutments for anterior implants. No previous study has compared the fracture loads between 2 different all-ceramic abutments restored by glass-ceramic crowns. Purpose. The purpose of this in vitro investigation was to quantify, the fracture load of implanted-supported Al2O3 and ZrO2 abutments restored with glass-ceramic crowns. Material and methods. Two ceramic abutments were tested: an Al2O3 abutment (CerAdapt) and a ZrO2 abutment (Wohlwend Innovative). The abutments (n = 10) were placed on Branemark dental implants and prepared for restoration with glass-ceramic crowns (IPS Empress). After fabrication, in accordance with the manufacturer's guidelines, the crowns were bonded to the all-ceramic abutments with a dual-polymerizing resin luting agent. The fracture loads (N) were determined by force application at an angle of 30 degrees by use of a computer-controlled universal testing device. The data were analyzed with the impaired t test (alpha = .05). Results. Statistical analysis showed significant differences between both groups (P = .001) of all-ceramic abutments, with mean fracture load values of 280.1 N ( +/- 103.1) for the A1(2)O(3) abutments and 737.6 N ( +/- 245.0) for the ZrO2 abutments. Conclusion. Within the limitations of this study, both all-ceramic abutments exceeded the established values for maximum incisal forces reported in the literature (90 to 370 N). The ZrO2 abutments were more than twice as resistant to fracture as the Al2O3-abutments.
引用
收藏
页码:325 / 331
页数:7
相关论文
共 50 条
  • [1] Fracture resistance of single-tooth implant-supported all-ceramic restorations: An in vitro study
    Att, W
    Kurun, S
    Gerds, T
    Strub, JR
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (02): : 111 - 116
  • [2] Fracture resistance of single-tooth implant-supported all-ceramic restorations after exposure to the artificial mouth
    Att, W
    Kurun, S
    Gerds, T
    Strub, JR
    JOURNAL OF ORAL REHABILITATION, 2006, 33 (05) : 380 - 386
  • [3] A study on the fracture strength of implant-supported restorations using milled ceramic abutments and all-ceramic crowns
    Cho, HW
    Dong, JK
    Jin, TH
    Oh, SC
    Lee, HH
    Lee, JW
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2002, 15 (01) : 9 - 13
  • [4] Fracture behavior of all-ceramic, implant-supported, and tooth–implant-supported fixed dental prostheses
    Abdul Rahman Alkharrat
    Marc Schmitter
    Stefan Rues
    Peter Rammelsberg
    Clinical Oral Investigations, 2018, 22 : 1663 - 1673
  • [5] Implant-supported all-ceramic bridges An update
    Herguth, Philipp
    Ruhstorfer, Miriam
    Gueth, Jan-Frederik
    Graf, Tobias
    IMPLANTOLOGIE, 2023, 31 (03): : 305 - 317
  • [6] Fracture behavior of all-ceramic, implant-supported, and tooth-implant-supported fixed dental prostheses
    Alkharrat, Abdul Rahman
    Schmitter, Marc
    Rues, Stefan
    Rammelsberg, Peter
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (04) : 1663 - 1673
  • [7] EFFECT OF PONTIC FRAMEWORK DESIGN ON THE FRACTURE RESISTANCE OF IMPLANT-SUPPORTED ALL-CERAMIC FIXED PARTIAL DENTURES
    Inan, Ozgur
    Secilmis, Asli
    Eraslan, Oguz
    JOURNAL OF APPLIED ORAL SCIENCE, 2009, 17 (05) : 533 - 538
  • [8] Fracture Load of Implant-Supported Zirconia All-Ceramic Crowns Luted with Various Cements
    Lim, Hyun-Pil
    Yoo, Jeong-Min
    Park, Sang-Won
    Yang, Hong-So
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (04) : 361 - 363
  • [9] Marginal Fit of Implant-Supported All-Ceramic Zirconia Frameworks
    Zaghloul, Hanaa Hassan
    Younis, Jihan Farouk
    JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (04) : 417 - 424
  • [10] Influence of abutment material on the gingival color of implant-supported all-ceramic restorations: a prospective multicenter study
    Bressan, Eriberto
    Paniz, Gianluca
    Lops, Diego
    Corazza, Boris
    Romeo, Eugenio
    Favero, Gianantonio
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (06) : 631 - 637