Out-Of-Field Neutron and Gamma Dose Estimated Using TLD-600/700 Pairs in the Wobbling Proton Therapy System

被引:0
|
作者
Chen, Y. [1 ]
Lin, Y. [1 ,2 ]
Chen, H. [1 ,3 ]
Tsai, H. [1 ,2 ,4 ]
机构
[1] Chang Gung Univ, Coll Med, Taoyuan, Taiwan
[2] Chang Gung Univ, Chang Gung Mem Hosp, Inst Radiol Res, Med Phys Res Ctr, Taoyuan, Taiwan
[3] Chang Gung Mem Hosp, Taoyuan, Taiwan
[4] Chang Gung Univ, Hlth Aging Res Ctr, Taoyuan, Taiwan
关键词
D O I
10.1118/1.4924957
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3472 / 3473
页数:2
相关论文
共 42 条
  • [1] Dual Detector System for Measuring Out-of-Field Neutron Dose in Proton Therapy
    Ziebell, A. L.
    Dowdell, S. J.
    Reinhard, M. I.
    Clasie, B.
    Wroe, A.
    Schulte, R. W.
    Lerch, M. L.
    Petaseca, M.
    Perevertaylo, V.
    Anokhin, I. E.
    Rosenfeld, A. B.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2358 - +
  • [2] Explicit estimation of out-of-field neutron and gamma dose equivalents during proton therapy using thermoluminescence-dosimeters
    Mukherjee, B.
    Lambert, J.
    Hentschel, R.
    Farr, J.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1952 - 1955
  • [3] DEMONSTRATION OF THE POTENTIAL AND DIFFICULTIES OF COMBINED TL AND OSL MEASUREMENTS OF TLD-600 AND TLD-700 FOR THE DETERMINATION OF THE DOSE COMPONENTS IN COMPLEX NEUTRON-GAMMA RADIATION FIELDS
    Oster, L.
    Eliyahu, I
    Horowitz, Y. S.
    Reshes, G.
    Shapiro, A.
    Garty, G.
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (03) : 383 - 388
  • [4] SIMPLE GAMMA, ALBEDO-NEUTRON PERSONNEL DOSIMETER USING 2 LIF(TLD-600) DETECTORS
    JOHNSON, TL
    NASH, AE
    GORBICS, SG
    LUERSEN, RB
    HEALTH PHYSICS, 1978, 35 (06): : 893 - 893
  • [5] Solid state diode - Ionization chamber method for measuring out-of-field neutron dose in proton therapy
    Ziebell, A. L.
    Clasie, B.
    Wroe, A.
    Schulte, R. W.
    Reinhard, M. I.
    Dowdell, S. J.
    Lerch, M. L.
    Petasecca, M.
    Perevertaylo, V. L.
    Zinets, O. S.
    Anokhin, I. E.
    Rosenfeld, A. B.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1638 - 1642
  • [6] Using a Novel Hybrid Computational Phantom to Calculate Out-Of-Field Dose and Equivalent Dose in Proton Therapy
    Kollitz, E.
    Han, H.
    Kim, C.
    Riboldi, M.
    Kamp, F.
    Newhauser, W.
    Dedes, G.
    Parodi, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E479 - E479
  • [7] Out-of-field dose equivalents delivered by proton therapy of prostate cancer
    Wroe, Andrew
    Rosenfeld, Anatoly
    Schulte, Reinhard
    MEDICAL PHYSICS, 2007, 34 (09) : 3449 - 3456
  • [8] Thermoluminescence Kinetic Parameters of TLD-600 and TLD-700 after 252Cf Neutron+Gamma and 90Sr-90Y Beta Radiations
    S.Iflazoglu
    V.E.Kafadar
    B.Yazici
    A.N.Yazici
    Chinese Physics Letters, 2017, 34 (01) : 125 - 129
  • [9] Thermoluminescence Kinetic Parameters of TLD-600 and TLD-700 after 252Cf Neutron+Gamma and 90Sr-90Y Beta Radiations
    Iflazoglu, S.
    Kafadar, V. E.
    Yazici, B.
    Yazici, A. N.
    CHINESE PHYSICS LETTERS, 2017, 34 (01)
  • [10] Validation of a Monte Carlo Framework for Out-of-Field Dose Calculations in Proton Therapy
    De Saint-Hubert, Marijke
    Verbeek, Nico
    Baeumer, Christian
    Esser, Johannes
    Wulff, Joerg
    Nabha, Racell
    Van Hoey, Olivier
    Dabin, Jeremie
    Stuckmann, Florian
    Vasi, Fabiano
    Radonic, Stephan
    Boissonnat, Guillaume
    Schneider, Uwe
    Rodriguez, Miguel
    Timmermann, Beate
    Thierry-Chef, Isabelle
    Brualla, Lorenzo
    FRONTIERS IN ONCOLOGY, 2022, 12