Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative reconstruction at 1.5T

被引:33
|
作者
Nazir, Muhummad Sohaib [1 ]
Neji, Radhouene [1 ,2 ]
Speier, Peter [3 ]
Reid, Fiona [4 ]
Stab, Daniel [5 ]
Schmidt, Michaela [3 ]
Forman, Christoph [3 ]
Razavi, Reza [1 ]
Plein, Sven [1 ,6 ]
Ismail, Tevfik F. [1 ]
Chiribiri, Amedeo [1 ]
Roujol, Sebastien [1 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, 3rd Floor Lambeth Wing,St Thomas Hosp, London SW1 7EH, England
[2] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[3] Siemens Healthcare, Erlangen, Germany
[4] Kings Coll London, Div Hlth & Social Care Res, London, England
[5] Siemens Healthcare Pty Ltd, Melbourne, Vic, Australia
[6] Univ Leeds, LIGHT Labs, Leeds Inst Cardiovasc & Metab Med, Clarendon Way, Leeds LS2 9JT, W Yorkshire, England
基金
英国医学研究理事会; 英国工程与自然科学研究理事会;
关键词
Cardiovascular magnetic resonance; Myocardial perfusion imaging; Simultaneous multi-slice; Image acceleration; Iterative reconstruction; HIGH-RESOLUTION; WHOLE-HEART; QUANTITATIVE-ANALYSIS; ISCHEMIC BURDEN; SENSE; MRI; ACQUISITION; CAIPIRINHA; MANAGEMENT; GRADIENTS;
D O I
10.1186/s12968-018-0502-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSimultaneous-Multi-Slice (SMS) perfusion imaging has the potential to acquire multiple slices, increasing myocardial coverage without sacrificing in-plane spatial resolution. To maximise signal-to-noise ratio (SNR), SMS can be combined with a balanced steady state free precession (bSSFP) readout. Furthermore, application of gradient-controlled local Larmor adjustment (GC-LOLA) can ensure robustness against off-resonance artifacts and SNR loss can be mitigated by applying iterative reconstruction with spatial and temporal regularisation. The objective of this study was to compare cardiovascular magnetic resonance (CMR) myocardial perfusion imaging using SMS bSSFP imaging with GC-LOLA and iterative reconstruction to 3 slice bSSFP.MethodsTwo contrast-enhanced rest perfusion sequences were acquired in random order in 8 patients: 6-slice SMS bSSFP and 3 slice bSSFP. All images were reconstructed with TGRAPPA. SMS images were also reconstructed using a non-linear iterative reconstruction with L1 regularisation in wavelet space (SMS-iter) with 7 different combinations for spatial ((sigma)) and temporal () regularisation parameters. Qualitative ratings of overall image quality (0=poor image quality, 1=major artifact, 2=minor artifact, 3=excellent), perceived SNR (0=poor SNR, 1=major noise, 2=minor noise, 3=high SNR), frequency of sequence related artifacts and patient related artifacts were undertaken. Quantitative analysis of contrast ratio (CR) and percentage of dark rim artifact (DRA) was performed.ResultsAmong all SMS-iter reconstructions, SMS-iter 6 ((sigma) 0.001 0.005) was identified as the optimal reconstruction with the highest overall image quality, least sequence related artifact and higher perceived SNR. SMS-iter 6 had superior overall image quality (2.500.53 vs 1.50 +/- 0.53, p=0.005) and perceived SNR (2.25 +/- 0.46 vs 0.75 +/- 0.46, p=0.010) compared to 3 slice bSSFP. There were no significant differences in sequence related artifact, CR (3.62 +/- 0.39 vs 3.66 +/- 0.65, p=0.88) or percentage of DRA (5.25 +/- 6.56 vs 4.25 +/- 4.30, p=0.64) with SMS-iter 6 compared to 3 slice bSSFP.Conclusions>SMS bSSFP with GC-LOLA and iterative reconstruction improved image quality compared to a 3 slice bSSFP with doubled spatial coverage and preserved in-plane spatial resolution. Future evaluation in patients with coronary artery disease is warranted.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Simultaneous multi slice (SMS) balanced steady state free precession first-pass myocardial perfusion cardiovascular magnetic resonance with iterative reconstruction at 1.5 T
    Muhummad Sohaib Nazir
    Radhouene Neji
    Peter Speier
    Fiona Reid
    Daniel Stäb
    Michaela Schmidt
    Christoph Forman
    Reza Razavi
    Sven Plein
    Tevfik F. Ismail
    Amedeo Chiribiri
    Sébastien Roujol
    Journal of Cardiovascular Magnetic Resonance, 20
  • [2] Simultaneous multi-slice steady-state free precession myocardial perfusion with iterative reconstruction and integrated motion compensation
    McElroy, Sarah
    Kunze, Karl P.
    Nazir, Muhummad Sohaib
    Speier, Peter
    Stab, Daniel
    Villa, Adriana D. M.
    Yazdani, Momina
    Vergani, Vittoria
    Roujol, Sebastien
    Neji, Radhouene
    Chiribiri, Amedeo
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [3] Assessment of myocardial perfusion to detect coronary artery stenoses by steady-state-free-precession magnetic resonance first-pass imaging
    Merkle, Nico
    Nusser, Thorsten
    Grebe, Olaf C.
    Kunze, Markus
    Kestler, Hans A.
    Kochs, Matthias
    Hombach, Vinzenz
    Wohrle, Jochen
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 89M - 90M
  • [4] Reproducibility of first-pass cardiovascular magnetic resonance myocardial perfusion
    Larghat, Abdulghani M.
    Maredia, Neil
    Biglands, John
    Greenwood, John P.
    Ball, Stephen G.
    Jerosch-Herold, Michael
    Radjenovic, Aleksandra
    Plein, Sven
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (04) : 865 - 874
  • [5] Assessment of myocardial perfusion for detection of coronary artery stenoses by steady-state, free-precession magnetic resonance first-pass imaging
    Merkle, Nico
    Woehrle, Jochen
    Grebe, Olaf
    Nusser, Thorsten
    Kunze, Markus
    Kestler, Hans A.
    Kochs, Matthias
    Hombach, Vinzenz
    HEART, 2007, 93 (11) : 1381 - 1385
  • [6] First-pass myocardial perfusion cardiovascular magnetic resonance at 3 Tesla
    Su, Mao-Yuan M.
    Yang, Kai-Chien
    Wu, Chau-Chung
    Wu, Yen-Wen
    Yu, Hsi-Yu
    Tseng, Rung-Yu
    Tseng, Wen-Yih I.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (04) : 633 - 644
  • [7] Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art
    Gerber, Bernhard L.
    Raman, Subha V.
    Nayak, Krishna
    Epstein, Frederick H.
    Ferreira, Pedro
    Axel, Leon
    Kraitchman, Dara L.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2008, 10 (1)
  • [8] Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art
    Bernhard L Gerber
    Subha V Raman
    Krishna Nayak
    Frederick H Epstein
    Pedro Ferreira
    Leon Axel
    Dara L Kraitchman
    Journal of Cardiovascular Magnetic Resonance, 10
  • [9] Assessment of coronary microvascular dysfunction in hypertrophic cardiomyopathy: First-pass myocardial perfusion cardiovascular magnetic resonance imaging at 1.5 T
    Huang, L.
    Han, R.
    Ai, T.
    Sun, Z.
    Bai, Y.
    Cao, Z.
    Morelli, J. N.
    Xia, L.
    CLINICAL RADIOLOGY, 2013, 68 (07) : 676 - 682
  • [10] Steady-state free precession sequences in myocardial first-pass perfusion MR imaging: comparison with TurboFLASH imaging
    Hunold, P
    Maderwald, S
    Eggebrecht, H
    Vogt, FM
    Barkhausen, J
    EUROPEAN RADIOLOGY, 2004, 14 (03) : 409 - 416