Differentiation Between Normal and Cancerous Cells at the Single Cell Level Using 3-D Electrode Electrical Impedance Spectroscopy

被引:24
|
作者
Kang, Giseok [1 ]
Yoo, Sung Keun
Kim, Hyoung-Ihl
Lee, Jong-Hyun [1 ,2 ]
机构
[1] Gwangju Inst Sci & Technol GIST, Grad Program Med Syst Engn GMSE, Sch Informat & Mechatron, Kwangju 500712, South Korea
[2] Gwangju Inst Sci & Technol GIST, Dept Nanobio Mat & Elect, Kwangju 500712, South Korea
基金
新加坡国家研究基金会;
关键词
Early-stage human breast cancer cell (MCF-7); microdevice for electrical impedance spectroscopy (mu EIS); microfluidic tunnel; normal human breast cell (MCF-10A); three-dimensional interdigitated electrodes (3-D IDE); LINES;
D O I
10.1109/JSEN.2011.2167227
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel microdevice for electrical impedance spectroscopy EIS is presented to differentiate between normal and cancerous cells at the single cell level with a high sensitivity. The device utilizes amicrofluidic tunnel structure, whose height is smaller than the cell diameters, to squeeze the target cells. Thus, the tight contact between the cells and electrodes allows the device to measure the intrinsic electrical properties of the cells with a higher sensitivity than through noncontact methods. Three-dimensional interdigitated electrodes (3-D IDE) are also employed to confine most of the electric field into the cell membrane, which contains the meaningful electrical properties. Consequently, the variance of the measured values could be reduced because the position of target cells is almost the same in every cell assay. The device well distinguishes normal human breast cells (MCF-10A) from early-stage human breast cancer cells (MCF-7) by means of electrical impedances at 500 kHz; the average differences of the real part and phase angle between the target cells are 44.4 Omega and 1.41 degrees, respectively. The proposed device also shows a high repeatability for the deionized (DI) water test conducted before and after each cell assay; the variances of the real part and phase angle of electrical impedance at 500 kHz are as small as 9.07 Omega and 0.27 degrees, respectively.
引用
收藏
页码:1084 / 1089
页数:6
相关论文
共 50 条
  • [1] DIFFERENTIATION BETWEEN NORMAL AND CANCEROUS RENAL TISSUES USING ELECTRICAL IMPEDANCE SPECTROSCOPY NEEDLE.
    Kim, Hyeon Woo
    Yun, Joho
    Park, Yangkyu
    Shin, Dong Gil
    Lee, Jeong Zoo
    Lee, Jong-Hyun
    Lee, Wan
    Lee, Chang Yell
    JOURNAL OF UROLOGY, 2016, 195 (04): : E1169 - E1169
  • [2] MICRO ELECTRICAL IMPEDANCE SPECTROSCOPY (μEIS) WITH CELL TRAPS IN VARIOUS SIZE FOR DIFFERENTIATION BETWEEN NORMAL AND CANCEROUS HUMAN UROTHELIAL CELLS
    Park, Y.
    Kim, H.
    Yun, J.
    Kang, G.
    Seo, S.
    Park, C.
    Yang, J.
    Chung, E.
    Lee, J. -H.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 355 - 358
  • [3] Differentiation Between Normal and Cancerous Human Urothelial Cell Lines Using Micro-Electrical Impedance Spectroscopy at Multiple Frequencies
    Hyeon Woo Kim
    Yangkyu Park
    Joho Yun
    Juhun Lim
    Jeong Zoo Lee
    Dong Gil Shin
    Jong-Hyun Lee
    Journal of Medical and Biological Engineering, 2019, 39 : 86 - 95
  • [4] Differentiation Between Normal and Cancerous Human Urothelial Cell Lines Using Micro-Electrical Impedance Spectroscopy at Multiple Frequencies
    Kim, Hyeon Woo
    Park, Yangkyu
    Yun, Joho
    Lim, Juhun
    Lee, Jeong Zoo
    Shin, Dong Gil
    Lee, Jong-Hyun
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2019, 39 (01) : 86 - 95
  • [5] Assay based on electrical impedance spectroscopy to discriminate between normal and cancerous mammalian cells
    Eduardo Giana, Fabian
    Jose Bonetto, Fabian
    Ines Bellotti, Mariela
    PHYSICAL REVIEW E, 2018, 97 (03)
  • [6] Microelectrical Impedance Spectroscopy for the Differentiation between Normal and Cancerous Human Urothelial Cell Lines: Real-Time Electrical Impedance Measurement at an Optimal Frequency
    Park, Yangkyu
    Kim, Hyeon Woo
    Yun, Joho
    Seo, Seungwan
    Park, Chang-Ju
    Lee, Jeong Zoo
    Lee, Jong-Hyun
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [7] DIFFERENTIATION BETWEEN NORMAL AND CANCEROUS HUMAN UROTHELIAL CELL LINES USING REAL-TIME MICRO-ELECTRICAL IMPEDANCE SPECTROSCOPY AT AN OPTIMAL FREQUENCY.
    Kim, Hyeon Woo
    Park, Yangkyu
    Yun, Joho
    Shin, Dong Gil
    Lee, Jeong Zoo
    Lee, Jong-Hyun
    Lee, Wan
    Lee, Chang Yell
    JOURNAL OF UROLOGY, 2016, 195 (04): : E1132 - E1132
  • [8] Discrimination Between Normal and Cancerous Human Urothelial Cell By Using a Novel Electrical Impedance Spectroscopy With Three-Dimensional Multiple Electrodes on a Trap
    Park, Yangkyu
    Yun, Joho
    Kim, Hyeon Woo
    Kong, Giseok
    Seo, Seungwan
    Lee, Jonghyun
    LABORATORY INVESTIGATION, 2015, 95 : 101A - 102A
  • [9] Discrimination Between Normal and Cancerous Human Urothelial Cell By Using a Novel Electrical Impedance Spectroscopy With Three-Dimensional Multiple Electrodes on a Trap
    Park, Yangkyu
    Yun, Joho
    Kim, Hyeon Woo
    Kang, Giseok
    Seo, Seungwan
    Lee, Jonghyun
    MODERN PATHOLOGY, 2015, 28 : 101A - 102A
  • [10] An Instrumental Electrode Configuration for 3-D Ultrasound Modulated Electrical Impedance Tomography
    Song, Xizi
    Xu, Yanbin
    Dong, Feng
    Witte, Russell S.
    IEEE SENSORS JOURNAL, 2017, 17 (24) : 8206 - 8214