Tests of Collared Concrete Columns under Eccentric Axial Load

被引:0
|
作者
Chapman, James R. [1 ]
Darras, A. J. [2 ]
Driver, Robert G. [2 ]
机构
[1] ISL Engn & Land Serv Ltd, Edmonton, AB, Canada
[2] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
columns; ductility; eccentric loading; rehabilitation; retrofit; steel collars; strengthening; GRAVITY LOADS; SEISMIC RESISTANCE; PERFORMANCE; CONFINEMENT; EFFICIENCY; RETROFIT; STRENGTH; BEHAVIOR; DESIGN; MODEL;
D O I
10.14359/51734488
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One strategy for the rehabilitation of existing reinforced concrete columns is to target the improvement of specific local vulnerabilities in the columns related to inadequate strength or ductility. Eight full-scale columns were tested to evaluate the performance of a rehabilitation technique for square or rectangular reinforced concrete columns using a system of discrete external steel collars. Unlike other external confinement methods such as steel jacketing and fiber-reinforced polymer (FRP) wrapping, the proposed collar system exploits the benefits of confining elements with significant flexural stiffness. The project investigates the effectiveness of steel collars for rehabilitating columns when they are loaded axially at an eccentricity from the column centroid. Parameters investigated include collar spacing, collar flexural stiffness, active confining pressure, and load eccentricity. The columns were tested under monotonically applied axial loading and exhibited both strengths and ductilities well in excess of what would be expected with conventionally reinforced columns.
引用
收藏
页码:117 / 127
页数:11
相关论文
共 50 条
  • [2] Experimental study on the behavior of GFRP reinforced concrete columns under eccentric axial load
    Sun, Li
    Wei, Minghai
    Zhang, Na
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 152 : 214 - 225
  • [3] High-strength concrete columns under eccentric load
    Canbay, Erdem
    Ozcebe, Guney
    Ersoy, Ugur
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2006, 132 (07): : 1052 - 1060
  • [4] TIED CONCRETE COLUMNS UNDER AXIAL LOAD AND FLEXURE
    SHEIKH, SA
    YEH, CC
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1990, 116 (10): : 2780 - 2800
  • [5] An Investigation of Compression Bearing Capacity of Concrete-Filled Rectangular Stainless Steel Tubular Columns under Axial Load and Eccentric Axial Load
    Cao, Bing
    Zhu, Longfei
    Jiang, Xintong
    Wang, Changsheng
    SUSTAINABILITY, 2022, 14 (14)
  • [6] Experimental tests of slender reinforced concrete columns under combined axial load and lateral force
    Barrera, A. C.
    Bonet, J. L.
    Romero, M. L.
    Miguel, P. F.
    ENGINEERING STRUCTURES, 2011, 33 (12) : 3676 - 3689
  • [7] Behavior of reinforced concrete columns with double spirals under axial and eccentric loads
    Zhou, Chunheng
    Chen, Zongping
    Huang, Zhenhua
    Cai, Liping
    JOURNAL OF BUILDING ENGINEERING, 2022, 51
  • [8] Effects of PVC and CFRP on confinement of reinforced concrete columns under eccentric load
    Abed H.S.
    Saeed H.H.
    Asian Journal of Civil Engineering, 2024, 25 (3) : 3025 - 3034
  • [9] Fire Resistance of Concrete Filled Square Steel Tube Columns Subjected to Eccentric Axial Load
    Chung, Kyungsoo
    Park, Suhee
    Choi, Sungmo
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2009, 9 (01) : 69 - 76
  • [10] Fire resistance of concrete filled square steel tube columns subjected to eccentric axial load
    Kyung-Soo, Chung
    Su-Hee, Park
    Sung-Mo, Choi
    9TH INTERNATIONAL CONFERENCE: MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, VOLS 1-3, 2008, : 500 - +