A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables:: A simulation case

被引:147
|
作者
Romero, Sergio [1 ]
Mananas, Miguel A. [1 ]
Barbanoj, Martel J. [2 ]
机构
[1] Tech Univ Catalonia, Biomed Engn Res Ctr, Dept Automat Control, ESAII, Barcelona 08028, Spain
[2] Autonomous Univ Barcelona, Dept Pharmacol & Therapeut, St Pau Hosp, Res Inst,Drug Res Ctr,CIM, E-08193 Barcelona, Spain
关键词
electroencephalography (EEG); electrooculography (EOG); ocular filtering; regression analysis; blind source separation (BSS); principal component analysis (PCA); independent component analysis (ICA);
D O I
10.1016/j.compbiomed.2007.12.001
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Eye movement artifacts represent a critical issue for quantitative electroencephalography (EEG) analysis and a number of mathematical approaches have been proposed to reduce their contribution in EEG recordings. The aim of this paper was to objectively and quantitatively evaluate the performance of ocular filtering methods with respect to spectral target variables widely used in clinical and functional EEG studies. In particular the following methods were applied: regression analysis and some blind source separation (BSS) techniques based on second-order statistics (PCA, AMUSE and SOBI) and on higher-order statistics (JADE, INFOMAX and FASTICA). Considering blind source decomposition methods, a completely automatic procedure of BSS based on logical rules related to spectral and topographical information was proposed in order to identify the components related to ocular interference. The automatic procedure was applied in different montages of simulated EEG and electrooculography (EOG) recordings: a full montage with 19 EEG and 2 EOG channels, a reduced one with only 6 EEG leads and a third one where EOG channels were not available. Time and frequency results in all of them indicated that AMUSE and SOB] algorithms preserved and recovered more brain activity than the other methods mainly at anterior regions. In the case of full montage: (i) errors were lower than 5% for all spectral variables at anterior sites; and (ii) the highest improvement in the signal-to-artifact (SAR) ratio was obtained up to 40 dB at these anterior sites. Finally, we concluded that second-order BSS-based algorithms (AMUSE and SOBI) provided an effective technique for eye movement removal even when EOG recordings were not available or when data length was short. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:348 / 360
页数:13
相关论文
共 6 条
  • [1] Comparative Study of Wavelet-Based Unsupervised Ocular Artifact Removal Techniques for Single-Channel EEG Data
    Khatun, Saleha
    Mahajan, Ruhi
    Morshed, Bashir I.
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2016, 4
  • [2] Evaluation of an automatic ocular filtering method for awake spontaneous EEG signals based on Independent Component Analysis
    Romero, S
    Mañanas, MA
    Riba, J
    Morte, A
    Gimenez, S
    Close, S
    Barbanoj, MJ
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 925 - 928
  • [3] Automatic Ocular Artifact Suppression From Human Operator's Eeg Based on a Combination Of Independent Component Analysis and Fuzzy C-Means Clustering Techniques
    Wang Raofen
    Zhang Jianhua
    Wang Xingyu
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 3175 - 3180
  • [4] Sonar based automatic target detection scheme for underwater environments using CFAR techniques: A comparative study
    Kalyan, B
    Balasuriya, A
    PROCEEDINGS OF THE 2004 INTERNATIONAL SYMPOSIUM ON UNDERWATER TECHNOLOGY, 2004, : 33 - 37
  • [5] The Clinical Application of EEG-Signals Recurrence Analysis as a Measure of Functional Connectivity: Comparative Case Study of Patients with Various Neuropsychiatric Disorders
    Jonak, Kamil
    Syta, Arkadiusz
    Karakula-Juchnowicz, Hanna
    Krukow, Pawel
    BRAIN SCIENCES, 2020, 10 (06) : 1 - 12
  • [6] Optic disc dose reduction in ocular brachytherapy using 125I notched COMS plaques: A simulation study based on current clinical practice
    Lee, Yongsook C.
    Lin, Shih-Chi
    Kim, Yongbok
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 57 - 70