On the Design Robustness and Long-Term Performance of the Most Used Electrodes in the Copper Electrowinning Industry

被引:2
|
作者
Wiechmann, Eduardo P. [1 ]
Morales, Anibal S. [2 ]
Aqueveque, Pablo [1 ]
Henriquez, Jorge A. [1 ]
Pino, Esteban J. [1 ]
Aburto, Leonardo G. [3 ]
机构
[1] Univ Concepcion, Dept Elect Engn, Concepcion 4089100, Chile
[2] Catholic Univ Most Holy Concept, Concepcion 4089100, Chile
[3] Minera Spence, Antofagasta 1240000, Chile
关键词
Copper electrowinning; current efficiency; finite-element analysis; internal resistance; lead-alloy anode; process performance; service lifetime; stainless steel cathode; ENERGY;
D O I
10.1109/TIA.2016.2574778
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Performance in copper electrowinning is directly linked to the electrode's hanger bar designs and plate assembly methods. The actual physical condition of the plate, hanger bar assembly, and the internal resistance of electrodes are critical factors in this process. Internal electrode resistances affect parallel anode-cathode pair resistances. Therefore, it also alters balanced copper deposits, current efficiency, and cell voltage and power consumption of electrowinning cells. This paper summarizes the design characteristics of commercial stainless steel cathodes and cold-rolled lead-alloy anodes. It includes the evaluation of electrode performances under typical operating conditions using 3-D finite-element method analysis. The proposed evaluation of internal electrode resistance comprises nonlinear effects of electrical conduction, heat generation, and electrode position. The analysis of the design robustness of electrodes considers the most important elements, which help to maintain high current efficiency and electrical performance in the long term; that is to say, mechanical strength, inherent straightness, resistance to dissolution of copper coating on hanger bars, galvanic corrosion of weld joints, and hanger bar resistance to annealing. Results are based on industrial measurements, test work by vendors, and tankhouse operating data for benchmarking. The performance evaluation considers internal electrical resistance, contact shape design, contact loading, average contact resistance, and lifetime current efficiency. The results highlight the relationship between the robustness of electrode design and long term performance.
引用
收藏
页码:4460 / 4469
页数:10
相关论文
共 50 条
  • [1] On the Design Robustness and Long Term Performance of the Most Used Electrodes in the Copper Electrowining Industry
    Wiechmann, Eduardo P.
    Morales, Anibal S.
    Aqueveque, Pablo
    Pino, Esteban J.
    Aburto, Leonardo G.
    2015 51ST IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2015,
  • [2] LONG-TERM PERFORMANCE OF PACEMAKER ELECTRODES
    KHAIR, GZ
    TRISTANI, FE
    KEELAN, MH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (05): : A67 - A67
  • [3] Long-term industry performance following IPOs
    Akhigbe, Aigbe
    Johnston, Jarrod
    Madura, Jeff
    QUARTERLY REVIEW OF ECONOMICS AND FINANCE, 2006, 46 (04): : 638 - 651
  • [4] Long-term cycling stability of polyaniline on graphite electrodes used for supercapacitors
    Zhang, Hairui
    Wang, Jixiao
    Chen, Yinying
    Wang, Zhi
    Wang, Shichang
    ELECTROCHIMICA ACTA, 2013, 105 : 69 - 74
  • [5] RECTIFIER AND DC BUS SYSTEM-DESIGN FOR THE COPPER ELECTROWINNING INDUSTRY
    BROWN, RR
    INDUSTRIAL APPLICATIONS SOCIETY : 36TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE, 1989, : 133 - 136
  • [6] RECTIFIER AND DC BUS SYSTEM-DESIGN FOR THE COPPER ELECTROWINNING INDUSTRY
    BROWN, RR
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (06) : 1116 - 1119
  • [8] LONG-TERM PERFORMANCE OF GEOCOMPOSITES USED AS HIGHWAY EDGE DRAINS
    KEARNS, RE
    GEOTEXTILES AND GEOMEMBRANES, 1992, 11 (4-6) : 513 - 521
  • [9] EVALUATION OF PROGNOSTIC FACTORS ON THE LONG-TERM PERFORMANCE OF COPPER IUDS
    ALLONEN, H
    LUUKKAINEN, T
    PYORALA, T
    NIELSEN, NC
    NYGREN, KG
    CONTRACEPTIVE DELIVERY SYSTEMS, 1983, 4 (04) : 50 - 50
  • [10] Study on long-term deformation performance of high performance concrete used in bridge
    College of Civil Engineering, Chongqing University, Chongqing 400045, China
    J. Inf. Comput. Sci., 2012, 14 (4131-4139):