Comparative Analysis of the Performance of Various Crystalloid Cardioplegic Solutions on Myocardial Protection After Prolonged Cold Ischemia

被引:7
|
作者
Lima, M. L. [1 ]
Fiorelli, A. I. [1 ,2 ]
Gomes, O. M. [1 ]
Pinheiro, B. B. [1 ]
Da Silva, M. A. F. [2 ]
Porto, L. A. B. J. [2 ]
Novaes, L. [1 ]
Stolf, N. A. G. [2 ]
Souza, D. R. [3 ]
机构
[1] Lab Sao Francisco Assis Fdn, Belo Horizonte, MG, Brazil
[2] Univ Sao Paulo, Inst Heart, Sao Paulo, Brazil
[3] Univ Hosp Orebro, Div Cardiothorac Surg, Orebro, Sweden
关键词
D O I
10.1016/j.transproceed.2010.12.044
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Introduction. The quality and effectiveness of myocardial protection are fundamental problems to expand the use of and consequently good outcomes of donated hearts for transplantation. Objective. The purpose of this investigation was to compare the cardioprotective effects of Krebs-Henseleit, Bretschneider-HTK, St Thomas, and Celsior solutions using a modified nonrecirculating Langendorff column model of isolated perfused rat heart during prolonged cold storage. Materials and Methods. After removal 36 rat hearts underwent isolated perfusion into a Langendorff apparatus using Krebs-Henseleit solution for a 15-minute period of recovery; we excluded organs that did not maintain an aortic pressure above 100 m Hg. Subsequently, we equally distributed the hearts into four groups according to the cardioprotection solution; group 1, Krebs-Henseleit (control); group II, Bretschneider-HTK; group III, St Thomas; and group IV, Celsior. Each heart received the specific cardioplegic solution at 10 C for 2-hour storage at 20 C, before a 15 minutes perfusion with Krebs-Henseleit solution for recovery and stabilization. After 60 additional minutes of perfusion, every 5 minutes we determined heart rate (HR), coronary flow (CF), left ventricular systolic pressure (LVSP), and positive and negative peak of the first derivative of left ventricular pressure (+dP/dt and dP/dt, respectively). Results. Comparative analysis by Turkey's test showed the following performances among the groups at 60 minutes of reperfusion: HR: II = IV > III > I; CF: II = IV > I = III; LVSP: IV > I = II = III; +dP/dt: IV > I = II = III; and dP/dt: IV = II > I = II. Conclusion. Cardioprotective solutions generally used in clinical practice are not able to avoid hemodynamic alterations in hearts exposed to prolonged ischemia. Celsior solution showed better performance than Bretschneider-HTK, St Thomas, and Krebs-Henseleit.
引用
收藏
页码:80 / 83
页数:4
相关论文
共 29 条
  • [1] ISCHEMIC MYOCARDIAL PROTECTION - COMPARISON OF NONOXYGENATED CRYSTALLOID, OXYGENATED CRYSTALLOID, AND OXYGENATED FLUOROCARBON CARDIOPLEGIC SOLUTIONS
    TABAYASHI, K
    MCKEOWN, PP
    MIYAMOTO, M
    LUEDTKE, AE
    THOMAS, R
    ALLEN, MD
    MISBACH, GA
    IVEY, TD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1988, 95 (02): : 239 - 246
  • [2] MYOCARDIAL PROTECTION DURING PROLONGED ISCHEMIC CARDIAC-ARREST - EXPERIMENTAL EVALUATION OF 3 CRYSTALLOID CARDIOPLEGIC SOLUTIONS
    CHONG, YS
    COTTIER, DS
    GAVIN, JB
    JOURNAL OF CARDIOVASCULAR SURGERY, 1994, 35 (01): : 35 - 44
  • [3] MYOCARDIAL PROTECTION IN THE NEONATAL HEART - A COMPARISON OF TOPICAL HYPOTHERMIA AND CRYSTALLOID AND BLOOD CARDIOPLEGIC SOLUTIONS
    CORNO, AF
    BETHENCOURT, DM
    LAKS, H
    HAAS, GS
    BHUTA, S
    DAVTYAN, HG
    FLYNN, WM
    DRINKWATER, DC
    LAIDIG, C
    CHANG, P
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1987, 93 (02): : 163 - 172
  • [4] MYOCARDIAL PROTECTION OF COLD CRYSTALLOID AND WARM BLOOD CARDIOPLEGIA A COMPARATIVE STUDY
    袁师敏
    朱朗标
    李功宋
    刘明辉
    董超
    余翼飞
    王冬青
    李佳春
    骆荩
    ChineseMedicalJournal, 1994, (07)
  • [5] MYOCARDIAL PROTECTION OF COLD CRYSTALLOID AND WARM BLOOD CARDIOPLEGIA A COMPARATIVE STUDY
    袁师敏
    朱朗标
    李功宋
    刘明辉
    董超
    余翼飞
    王冬青
    李佳春
    骆荩
    中华医学杂志(英文版), 1994, (07) : 37 - 42
  • [6] Comparative experimental study of myocardial protection with crystalloid solutions for heart transplantation
    Lima, Melchior Luiz
    Fiorelli, Alfredo Inacio
    Vassallo, Dalton Valentim
    Pinheiro, Bruno Botelho
    Groppo Stolf, Noedir Antonio
    Gomes, Otoni Moreira
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2012, 27 (01): : 110 - 116
  • [7] MYOCARDIAL PROTECTION OF COLD CRYSTALLOID AND WARM BLOOD CARDIOPLEGIA - A COMPARATIVE-STUDY
    YUAN, SM
    ZHU, LB
    LI, GS
    LIU, MH
    DONG, C
    YU, YF
    WANG, DQ
    LI, JC
    LUO, J
    CHINESE MEDICAL JOURNAL, 1994, 107 (07) : 515 - 520
  • [8] Metabolic recovery after global myocardial ischemia: Effects of blood cardioplegic solutions
    Carrier, M
    Khalil, A
    Eng, AT
    Solymoss, BC
    Pelletier, LC
    CANADIAN JOURNAL OF CARDIOLOGY, 1996, 12 (06) : 607 - 611
  • [9] PROLONGED MYOCARDIAL ISCHEMIA AFTER COLD PRESSOR TEST - DETECTION OF ISCHEMIA USING POSITRON TOMOGRAPHY
    SELWYN, AP
    LABBATE, A
    ALLAN, RM
    HORLOCK, P
    MASERI, A
    BRITISH HEART JOURNAL, 1981, 45 (03): : 342 - 342
  • [10] Chemical Composition of Cardioplegic Solutions and Myocardial Protection A systematic review and meta-analysis
    Furnica, Cristina
    Chistol, Raluca Ozana
    Constantin, Maria-Magdalena Leon
    Cobzaru, Roxana Gabriela
    Ripa, Carmen Valerica
    Iliescu, Diana Bulgaru
    Tinica, Grigore