A technique is proposed to measure the modulation transfer function of a slow-scan CCD camera mounted on a transmission electron microscope. The measurement is done from only three images: two images taken at different magnifications of a thin amorphous specimen and one image taken without a specimen in the electron beam. The advantage of this technique is that neither the CCD camera has to be dismounted nor special equipment has to be used. The first experiments show that this technique gives reproducible results, but more experiments are necessary to compare the results with other methods.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 15 条
  • [1] Application of a slow-scan CCD camera for TEM-imaging of biomolecules
    Heinz, G
    Peter, T
    Hermann, FK
    EUROPEAN JOURNAL OF CELL BIOLOGY, 1997, 74 : 132 - 132
  • [2] QUANTITATIVE IMAGING AND DIFFRACTION OF ZEOLITES USING A SLOW-SCAN CCD CAMERA
    PAN, M
    CROZIER, PA
    ULTRAMICROSCOPY, 1993, 52 (3-4) : 487 - 498
  • [3] Electron detection characteristics of a slow-scan CCD camera, imaging plates and film, and electron image restoration
    Zuo, JM
    MICROSCOPY RESEARCH AND TECHNIQUE, 2000, 49 (03) : 245 - 268
  • [4] INTENSITY MEASUREMENT OF EQUAL-THICKNESS FRINGES IN TEM IMAGES OF WEDGE-SHAPED GAAS AND INP CRYSTALS BY A SLOW-SCAN CCD CAMERA
    NISHIO, K
    KAKIBAYASHI, H
    ISSHIKI, T
    SAIJO, H
    SHIOJIRI, M
    JOURNAL OF ELECTRON MICROSCOPY, 1994, 43 (04): : 198 - 202
  • [5] CCD Aerial Camera Modulation Transfer Function Test and Analysis
    Zhu, Haibin
    Xu, Zhigang
    INTERNATIONAL CONFERENCE ON ELECTRONIC INFORMATION TECHNOLOGY AND INTELLECTUALIZATION (ICEITI 2016), 2016, : 178 - 184
  • [6] Transmission electron microscopy study of zeolite TPA/ZSM-5 using a slow-scan CCD camera
    Ohnishi, N
    Hiraga, KJ
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1996, 217 : 142 - 146
  • [7] QUANTITATIVE CHARACTERIZATION OF POINT-SPREAD FUNCTION AND DETECTION QUANTUM EFFICIENCY FOR A YAG SCINTILLATOR SLOW-SCAN CCD CAMERA
    WEICKENMEIER, AL
    NUCHTER, W
    MAYER, J
    OPTIK, 1995, 99 (04): : 147 - 154
  • [8] Research of modulation transfer function measurement of CCD camera with rectangle target
    Nie, P. (np0618@126.com), 1600, Chinese Optical Society (32):
  • [9] Modulation Transfer Function Measurement System at Different Contrasts for CCD Camera
    Li, Wenjuan
    Liang, Chuan
    Jin, Ningzhi
    Zhou, Meilan
    INDUSTRIAL INSTRUMENTATION AND CONTROL SYSTEMS, PTS 1-4, 2013, 241-244 : 648 - 652
  • [10] NONDESTRUCTIVE DETECTION OF FIREFLY LUCIFERASE (LUC) ACTIVITY IN SINGLE PLANT-CELLS USING A COOLED, SLOW-SCAN CCD CAMERA AND AN OPTIMIZED ASSAY
    KOST, B
    SCHNORF, M
    POTRYKUS, I
    NEUHAUS, G
    PLANT JOURNAL, 1995, 8 (01): : 155 - 166