Ultrasound-guided needle positioning near the sciatic nerve to elicit compound muscle action potentials from the gastrocnemius muscle of the rat

被引:8
|
作者
Nijhuis, T. H. J. [1 ]
Smits, E. S. [1 ]
van Neck, J. W. [1 ]
Visser, G. H. [2 ]
Walbeehm, E. T. [1 ]
Blok, J. H. [2 ]
Hovius, S. E. R. [1 ]
机构
[1] Univ Med Ctr, Erasmus MC, Dept Plast Reconstruct & Hand Surg, NL-3000 CA Rotterdam, Netherlands
[2] Univ Med Ctr, Erasmus MC, Dept Clin Neurophysiol, NL-3000 CA Rotterdam, Netherlands
关键词
Ultrasound; Nerve visualisation; CMAP; REGENERATION; ULTRASONOGRAPHY;
D O I
10.1016/j.jneumeth.2010.10.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of ultrasound-guided electrode positioning in near-nerve myography was investigated. This is a minimally invasive technique that allows repeated measurements to increase accuracy and hence decreases animal numbers. Ultrasound imaging of the sciatic nerve was performed in nine rats using a 55 MHz high-end transducer. Once visualised, a monopolar needle electrode was placed through the skin near this nerve. Upon stimulation, two surface electrodes, placed over the gastrocnemius muscle, recorded compound muscle action potentials (CMAPs). Reproducibility was tested having two teams of investigators perform the recordings consecutively. Reliability of the procedure was determined by comparing the ultrasound method to the conventional technique, which requires an incision through muscle and skin to expose the sciatic nerve. In all animals the sciatic nerve was visible on ultrasound images. Both methods showed CMAP latencies (duration was determined as the time interval between the onset latency and positive peak). The conventional method had a mean latency of 3.4 +/- 0.5 ms, our method had a mean latency of 3.3 +/- 0.5 ms. Reproducibility was excellent (observed latencies and amplitudes: 3.3 versus 3.3 ms and 25.6 +/- 5.1 mV versus 22.5 +/- 8.8 mV) resulting in a coefficient of variation for duration of 2.1% and for amplitude 6.7%. Interclass correlation coefficient was 0.828 for duration. Comparing the three different measurements no significant differences were found and our new method can therefore be considered reliable and comparable to the conventional method. Ultrasound-guided near-nerve needle positioning is a reproducible and reliable minimally invasive method for selectively eliciting CMAPs, which allows repeated CMAP measurements for studying nerve regeneration in rats. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:283 / 286
页数:4
相关论文
共 50 条
  • [1] Ultrasound-guided needle positioning in sensory nerve conduction study of the sural nerve
    Kamm, Christian P.
    Scheidegger, Olivier
    Roesler, Kai M.
    CLINICAL NEUROPHYSIOLOGY, 2009, 120 (07) : 1342 - 1345
  • [2] Ultrasound-guided needle positioning in sensory nerve conduction study of the saphenous nerve
    Evangelopoulos, M.
    Humpert, S.
    Weck, A.
    Roesler, K.
    JOURNAL OF NEUROLOGY, 2011, 258 : 124 - 125
  • [3] SMALL SPONTANEOUS POTENTIALS IN CAT GASTROCNEMIUS MUSCLE AFTER PROLONGED SCIATIC NERVE STIMULATION
    MUCHNIK, S
    RUBINSTEIN, EH
    ACTA PHYSIOLOGICA LATINOAMERICANA, 1966, 16 (04) : 389 - +
  • [4] Refining the rat sciatic nerve block: a novel ultrasound-guided technique
    Hughey, Scott
    Campbell, Donald
    Rapp-Santos, Kamala
    Cole, Jacob
    Booth, Gregory
    Longwell, Jason
    Stedje-Larsen, Eric
    LABORATORY ANIMALS, 2022, 56 (02) : 191 - 195
  • [5] Ultrasound-Guided Anterior Approach to a Sciatic Nerve Block Influence of Lower Limb Positioning on the Visibility and Depth of the Sciatic Nerve
    Kim, Ha-Jung
    Chin, Ki Jinn
    Kim, Hyungtae
    Jang, Hwa-young
    Bin, Seong-il
    Ro, Young-jin
    Koh, Won Uk
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (08) : 1641 - 1647
  • [6] Spatial variation of compound muscle action potentials across human gastrocnemius medialis
    Vieira, Taian M.
    Botter, Alberto
    Minetto, Marco A.
    Hodson-Tole, Emma F.
    JOURNAL OF NEUROPHYSIOLOGY, 2015, 114 (03) : 1617 - 1627
  • [7] Compound muscle action potentials during repetitive nerve stimulation
    Asawa, T
    Shindo, M
    Momoi, H
    MUSCLE & NERVE, 2004, 29 (05) : 724 - 728
  • [8] REPRODUCIBILITY OF SENSORY NERVE CONDUCTION STUDIES OF THE SURAL NERVE USING ULTRASOUND-GUIDED NEEDLE POSITIONING
    Scheidegger, Olivier
    Kueffer, Alexander F.
    Kamm, Christian P.
    Roesler, Kai M.
    MUSCLE & NERVE, 2011, 44 (06) : 873 - 876
  • [9] THE NEUROMUSCULAR BLOCKING ACTIVITY OF SPECTINOMYCIN ON THE RAT SCIATIC NERVE-GASTROCNEMIUS MUSCLE PREPARATION
    RENNA, G
    CAGIANO, R
    FIORE, T
    CUOMO, V
    PHARMACOLOGICAL RESEARCH COMMUNICATIONS, 1986, 18 (05): : 451 - 457
  • [10] Ultrasound-guided and 'blind' sciatic nerve injection techniques: Comparison in rat cadavers
    Castro, Douglas
    Ishihara, Toshitsugu
    Hofmeister, Erik H.
    Clark-Price, Stuart
    Portela, Diego A.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2024, 51 (03) : 298 - 304