Experimental study of the swing compressor with two discharge channels for household air-conditioner applications

被引:5
|
作者
Pan, Xi [1 ]
Pan, Shulin [2 ]
Zhang, Hanyue [1 ]
Xie, Junlong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Energy & Power Engn, Wuhan 417000, Peoples R China
[2] Hunan Univ Humanities Sci & Technol, Sch Energy & Elect Engn, Loudi 417000, Peoples R China
关键词
Swing compressor; Two discharge channels; Isentropic efficiency; Volumetric efficiency; COP; LEAKAGE CHARACTERISTICS; MODEL; PUMP;
D O I
10.1016/j.ijrefrig.2021.09.024
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a novel swing compressor with two discharge channels (SCTC) is introduced, which can be an alternative compressor applied in household air-conditioner. SCTC has two discharge ports. The first one without discharge valve operates at all shaft speed and the other one with a high stiffness discharge valve operates at high shaft speed, which is helpful to improve the service life of compressor and discharge valve. Additionally, the discharge close volume is eliminated and the liquid strike can be prevented. In order to obtain the performance of SCTC, a prototype has been tested at three different shaft speeds and its volumetric efficiency, adiabatic efficiency, COP and noise characteristic have been analyzed. The performance of SCTC is always better than that of the swing compressor with no valve (SCNV). Besides, compared with the conventional swing compressor, the COP of SCTC increases by 2.26% at the shaft speed of 1800 r.min(-1).
引用
收藏
页码:56 / 62
页数:7
相关论文
共 50 条
  • [1] Study on Characteristics of the Linear Air-Conditioner Compressor at Varied Operating Conditions
    Xie, Jiefei
    Li, Xinhua
    Zhang, Hong
    ADVANCED MANUFACTURING SYSTEMS, PTS 1-3, 2011, 201-203 : 632 - 636
  • [2] Identification of noise sources in scroll compressor for air-conditioner
    Lee, JK
    KSME INTERNATIONAL JOURNAL, 2000, 14 (06): : 597 - 604
  • [3] Identification of noise sources in scroll compressor for air-conditioner
    Jin-Kab Lee
    KSME International Journal, 2000, 14 : 597 - 604
  • [4] Experimental research on the operational characteristics of household air-conditioner with condenser heat recovery
    Zhang, Weijie
    Gao, Yanbing
    Wei, Yiran
    FIRST INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT, PROCEEDINGS VOLS 1-3, 2008, : 1444 - 1451
  • [5] Efficiency enhancement of an air-conditioner utilizing nanofluids: An experimental study
    Ahmed, Faizan
    Khan, Waqar Ahmed
    ENERGY REPORTS, 2021, 7 (07) : 575 - 583
  • [6] Experimental research on the operational characteristics of household air-conditioner with domestic hot water supply
    Gao, Yanbing
    Huai, Lanlan
    Jin, Wen
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 677 - 682
  • [7] AUTOMOBILE AIR-CONDITIONER COMPRESSOR TROUBLESHOOTING - AN EXPERT SYSTEM APPROACH
    CHEN, JG
    ISHIKO, K
    COMPUTERS IN INDUSTRY, 1990, 13 (04) : 337 - 345
  • [8] Sensorless Brushless DC Motor drive for air-conditioner compressor
    Wu, ZG
    Wang, J
    Ying, JP
    Zeng, HJ
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 968 - 971
  • [9] Vector control for air-conditioner DC compressor based on PLL
    Sun, Chengbo
    Song, Dan
    Chen, Guocheng
    Wu, Chunhua
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2009, 24 (04): : 78 - 84
  • [10] Experimental investigation on the vibration characteristics of the compressor in the outdoor unit of a household air conditioner
    Wu, Junhong
    Ma, Yubo
    Xia, Zengqiang
    Zhang, Hongtao
    Pan, Xi
    Xie, Junlong
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024,