The influence of bubble-bubble interactions on contrast agent microbubble-jetting during initial exposure to 200 kHz focused ultrasound

被引:0
|
作者
Cleve, Sarah [1 ]
Prentice, Paul [2 ]
机构
[1] Univ Lyon 1, Univ Lyon, Ecole Cent Lyon, INSA Lyon,Lab Mecan Fluides & Acoust,UMR 5509, Lyon, France
[2] Univ Glasgow, Ctr Med & Ind Ultrason, Glasgow, Lanark, Scotland
基金
欧洲研究理事会;
关键词
ultrasound contrast agent; microbubble; jetting;
D O I
10.1109/ultsym.2019.8925619
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The initial response of contrast agent microbubbles to a burst of 200 kHz focused ultrasound with 1.5 MPa peak-negative pressure amplitude is studied. Directed jetting along the axis of propagation of the ultrasound is observed and the influence of the pressure-gradients on the bubble dynamics evidenced. Furthermore, the influence of nearby bubbles on the jetting behavior is investigated. Bubbles tend to jet towards other bubbles and to be influenced in their dynamics. Moreover, the more bubbles share the same volume, the weaker the jets become.
引用
收藏
页码:1346 / 1348
页数:3
相关论文
共 7 条
  • [1] CONTRAST AGENT MICROBUBBLE JETTING DURING INITIAL INTERACTION WITH 200-KHZ FOCUSED ULTRASOUND
    Cleve, Sarah
    Inserra, Claude
    Prentice, Paul
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (11): : 3075 - 3080
  • [2] Detection of ultrasound contrast agent microbubble with constructed bubble wavelet
    LI Bin WAN Mingxi(The Key Laboratory of Biomedical Information Engineering of Ministry of Education
    ChineseJournalofAcoustics, 2005, (02) : 131 - 145
  • [3] Destruction of contrast agent microbubbles in the ultrasound field: The fate of the microbubble shell and the importance of the bubble gas content
    Klibanov, AL
    Hughes, MS
    Wojdyla, JK
    Wible, JH
    Brandenburger, GH
    ACADEMIC RADIOLOGY, 2002, 9 : S41 - S45
  • [4] Contrast Agent Kinetics in the Rabbit Brain During Exposure to Focused Ultrasound
    Goertz, David E.
    Wright, Cameron
    Hynynen, Kullervo
    2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 2062 - 2065
  • [5] The influence of inter-bubble spacing on the resonance response of ultrasound contrast agent microbubbles
    Yusefi, Hossein
    Helfield, Brandon
    ULTRASONICS SONOCHEMISTRY, 2022, 90
  • [6] Contrast agent shell properties effects on heat deposition in bubble enhanced high intensity focused ultrasound
    Gnanaskandan, Aswin
    Hsiao, Chao-Tsung
    Chahine, Georges
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 149 (01): : 421 - 434
  • [7] Effect of microbubble contrast agent during high intensity focused ultrasound ablation on rabbit liver in vivo
    Chung, Dong Jin
    Cho, Se Hyun
    Lee, Jae Mun
    Hahn, Seong-Tae
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E519 - E523