T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning

被引:30
|
作者
Freedman, Joshua N. [1 ,2 ]
Collins, David J. [2 ]
Bainbridge, Hannah [3 ,4 ]
Rank, Christopher M. [5 ]
Nill, Simeon [1 ]
Kachelrie, Marc [5 ]
Oelfke, Uwe [1 ]
Leach, Martin O. [2 ]
Wetscherek, Andreas [1 ]
机构
[1] Inst Canc Res, Joint Dept Phys, London, England
[2] Inst Canc Res, CR UK Canc Imaging Ctr, 123 Old Brompton Rd, London SW7 3RP, England
[3] Inst Canc Res, Joint Dept Radiotherapy, London, England
[4] Royal Marsden NHS Fdn Trust, 123 Old Brompton Rd, London SW7 3RP, England
[5] German Canc Res Ctr, Med Phys Radiol, Heidelberg, Germany
关键词
4D MRI; motion model; motion vector field; MR-linac; radiotherapy treatment planning; 4D-T2w MRI; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; CORONARY MR-ANGIOGRAPHY; RESPIRATORY MOTION; LUNG MOTION; RADIATION-THERAPY; IMAGES; MODEL; REGISTRATION; NAVIGATOR; CANCER;
D O I
10.1097/RLI.0000000000000381
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. Materials and Methods: Ten patients with primary non-small cell lung cancer were scanned at 1.5 T axially with a volumetric T2-weighted turbo spin echo sequence gated to exhalation and a volumetric T1-weighted stack-of-stars spoiled gradient echo sequence with golden angle spacing acquired in free breathing. From the latter, 20 respiratory phaseswere reconstructed using the recently developed 4D joint MoCo-HDTV algorithm based on the self-gating signal obtained from the k-space center. Motion vector fields describing the respiratory cycle were obtained by deformable image registration between the respiratory phases and projected onto the T2-weighted image volume. The resulting 4D-T2w volumes were verified against the 4D-T1w volumes: an edge-detection method was used to measure the diaphragm positions; the locations of anatomical landmarks delineated by a radiation oncologist were compared and normalized mutual information was calculated to evaluate volumetric image similarity. Results: High-resolution 4D-T2w MRI was obtained. Respiratory motion was preserved on calculated 4D-T2w MRI, with median diaphragm positions being consistent with less than 6.6 mm (2 voxels) for all patients and less than 3.3 mm (1 voxel) for 9 of 10 patients. Geometrical positions were coherent between 4D-T1w and 4D-T2w MRI as Euclidean distances between all corresponding anatomical landmarks agreed to within 7.6 mm (Euclidean distance of 2 voxels) and were below 3.8 mm (Euclidean distance of 1 voxel) for 355 of 470 pairs of anatomical landmarks. Volumetric image similarity was commensurate between 4D-T1w and 4D-T2w MRI, as mean percentage differences in normalized mutual information (calculated over all respiratory phases and patients), between corresponding respiratory phases of 4D-T1w and 4D-T2w MRI and the tie-phase of 4D-T1w and 3-dimensional T2w MRI, were consistent to 0.41% +/- 0.37%. Four-dimensional T2w MRI displayed tumor extent, structure, and position more clearly than corresponding 4D-T1w MRI, especially when mobile tumor sites were adjacent to organs at risk. Conclusions: A methodology to obtain 4D-T2w MRI that retrospectively applies the motion information from 4D-T1w MRI to 3-dimensional T2w MRI was developed and verified. Four-dimensional T2w MRI can assist clinicians in delineating mobile lesions that are difficult to define on 4D-T1w MRI, because of poor tumor-tissue contrast.
引用
收藏
页码:563 / 573
页数:11
相关论文
共 50 条
  • [1] Accelerating 4D image reconstruction for magnetic resonance-guided radiotherapy
    Lecoeur, Bastien
    Barbone, Marco
    Gough, Jessica
    Oelfke, Uwe
    Luk, Wayne
    Gaydadjiev, Georgi
    Wetscherek, Andreas
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 27
  • [2] Improving the Quality of T2-Weighted 4D Magnetic Resonance Imaging for Clinical Evaluation
    Du, D.
    Caruthers, S.
    Glide-Hurst, C.
    Low, D.
    Mutic, S.
    Hu, Y.
    MEDICAL PHYSICS, 2014, 41 (06) : 192 - 192
  • [3] Robustness of radiomics features on 0.35 T magnetic resonance imaging for magnetic resonance-guided radiotherapy
    Michalet, Morgan
    Valenzuela, Gladis
    Debuire, Pierre
    Riou, Olivier
    Azria, David
    Nougaret, Stephanie
    Tardieu, Marion
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [4] An efficient model to guide prospective T2-weighted 4D magnetic resonance imaging acquisition
    Du, Dongsu
    Mutic, Sasa
    Li, H. Harold
    Hu, Yanle
    MEDICAL PHYSICS, 2018, 45 (06) : 2453 - 2462
  • [5] Clinically applicable T2-weighted 4D Magnetic Resonance Imaging with good abdominal contrast
    Tekelenburg, D.
    Gurney-Champion, O.
    Lens, E.
    Van der Horst, A.
    Nederveen, A.
    Biegun, A. K.
    Bel, A.
    Van Kesteren, Z.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S440 - S441
  • [6] T2-weighted cardiovascular magnetic resonance imaging
    Abdel-Aty, Hassan
    Simonetti, Orlando
    Friedrich, Matthias G.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) : 452 - 459
  • [7] Optimization of T2-weighted imaging for shoulder magnetic resonance arthrography by synthetic magnetic resonance imaging
    Lee, Seung Hyun
    Lee, Young Han
    Hahn, Seok
    Yang, Jaemoon
    Song, Ho-Taek
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2018, 59 (08) : 959 - 965
  • [8] A systematic review of 4D magnetic resonance imaging techniques for abdominal radiotherapy treatment planning
    Aljaafari, Lamyaa
    Bird, David
    Buckley, David L.
    Al-Qaisieh, Bashar
    Speight, Richard
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 31
  • [9] Multi-parametric optimization of magnetic resonance imaging sequences for magnetic resonance-guided radiotherapy
    Fahad, Hafiz Muhammad
    Dorsch, Stefan
    Zaiss, Moritz
    Karger, Christian P.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 28
  • [10] Diagnostic value of T2-weighted magnetic resonance imaging in hematomyelia
    Tetsuka, Syuichi
    Sawada, Jun
    Suzuki, Tomohiro
    Ogawa, Tomoko
    Hashimoto, Ritsuo
    NEUROLOGY AND CLINICAL NEUROSCIENCE, 2024, 12 (06): : 394 - 395