MINIMUM AIRFLOW RATES TO DILUTE 8290 CONCENTRATIONS ARISING FROM LEAKS IN ROOM AIR CONDITIONERS

被引:1
|
作者
Colbourne, D. [1 ]
Suen, K. O. [2 ]
机构
[1] Re Phridge, POB 4745, Stratford Upon Avon CV37 1FE, England
[2] UCL, Dept Mech Engn, Torrington Pl, London WC1E 7JE, England
关键词
Hydrocarbon refrigerant; 8290; flammable; leakage; concentration; safety; room air conditioner;
D O I
10.18462/iir.gl.2018.1104
中图分类号
O414.1 [热力学];
学科分类号
摘要
Currently R290 is used to a limited extent in room air conditioners, such as split, portable and window types. The product standard IEC 60335-2-40 currently specifies requirements to limit the charge of flammable refrigerants in such a way that it obstructs the wider use of R290. This is particularly challenging in warm countries where the heat load is greater and thus charge sizes need to be larger for a given room size, inferring higher concentrations in the event of a leak. Relying on the airflow of an indoor unit can be used to dilute a refrigerant leak and thus prevent flammable concentrations forming, despite the charge quantity being substantially greater than that currently permitted in the current standard. Research has been carried out to determine the minimum airflow rate from an air conditioner necessary to achieve sufficient dilution. A numerical model based on entrainment theory was developed and supported by experimentally analysing the behaviour of releases under various conditions with RACS airflow.
引用
收藏
页码:36 / 45
页数:10
相关论文
共 29 条
  • [1] ASSESSMENT OF FACTORS AFFECTING R290 CONCENTRATIONS ARISING FROM LEAKS IN ROOM AIR CONDITIONERS
    Colbourne, D.
    Suen, K. O.
    13TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS: NATURAL REFRIGERANT SOLUTIONS FOR WARM CLIMATE COUNTRIES, 2018, : 25 - 35
  • [2] MINIMUM AIRFLOW RATES TO DILUTE A2L REFRIGERANT LEAKS FROM REFRIGERATION SYSTEMS
    Colbourne, D.
    Suen, K. O.
    1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS, 2018, : 545 - 555
  • [3] Airflow optimization for thermal comfort and energy efficiency for room air conditioners
    Tanaka, Ryuta
    Nabi, Saleh
    Nonaka, Mio
    PROCEEDINGS OF BUILDING SIMULATION 2021: 17TH CONFERENCE OF IBPSA, 2022, 17 : 2419 - 2426
  • [4] Potential electricity savings by implementing minimum energy efficiency standards for room air conditioners in Malaysia
    Masjuki, HH
    Mahlia, TMI
    Choudhury, IA
    ENERGY CONVERSION AND MANAGEMENT, 2001, 42 (04) : 439 - 450
  • [5] CONSERVED ENERGY FROM ROOM AIR-CONDITIONERS FOR WATER HEATING
    MONERASINGHE, NJ
    RATNALINGAM, R
    LEE, BS
    ENERGY CONVERSION AND MANAGEMENT, 1982, 22 (02) : 171 - 173
  • [6] R290 CONCENTRATIONS ARISING FROM LEAKS IN COMMERCIAL REFRIGERATION CABINETS
    Colbourne, D.
    Suen, K. O.
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 25 - 33
  • [7] Emissions of F-gases from room air conditioners in China and scenarios to 2060
    Hu, Shan
    Yang, Ziyi
    Yan, Da
    Wang, Baolong
    Jiang, Yi
    ENERGY AND BUILDINGS, 2023, 299
  • [8] REMOVAL OF POLLEN AND FUNGI FROM ROOM AIR - COMPARISON OF WINDOW AIR FILTERS AND WINDOW COMBINATION AIR CONDITIONERS-AIR FILTERS
    UNGER, L
    MEYERS, TS
    ANNALS OF ALLERGY, 1961, 19 (07): : 755 - &
  • [9] How do the appliance energy standards work in China? Evidence from room air conditioners
    Yu, Hao
    Tang, Bao-Jun
    Yuan, Xiao-Chen
    Wang, Shouyang
    Wei, Yi-Ming
    ENERGY AND BUILDINGS, 2015, 86 : 833 - 840
  • [10] Particulate concentrations within a reduced-scale room operated at various air exchange rates
    Faulkner, W. Brock
    Memarzadeh, Farhad
    Riskowski, Gerald
    Hamilton, Keith
    Chang, Ching-Zu
    Chang, Jieh-Ren
    BUILDING AND ENVIRONMENT, 2013, 65 : 71 - 80