Electrochemical method for measuring hydrogen permeability through metals

被引:17
|
作者
Akamatsu, T
Kume, Y
Komiya, K
Yukawa, H
Morinaga, M
Yamaguchi, S
机构
[1] Nagoya Univ, Grad Sch Engn, Dept Mat Sci & Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Nagoya Inst Technol, Dept Mat Sci & Engn, Showa Ku, Nagoya, Aichi 4668555, Japan
基金
日本学术振兴会;
关键词
hydrogen permeable membrane; limiting current method; palladium; permeability;
D O I
10.1016/j.jallcom.2004.10.007
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An electrochemical method based on the limiting current measurement has been proposed for measuring the hydrogen permeability through metal membrane. In this method, the hydrogen permeability can be obtained directly from the limiting current measurement, if the diffusion through the metal is the rate-limiting process of the hydrogen permeation. Based on this concept, an electrochemical device has been developed and applied to the measurement of the hydrogen permeability of pure palladium and V-15 mol% Ni alloy at high temperature up to 673 K. lt is shown that the measured hydrogen permeability through pure palladium and V-Ni alloy are in good agreement with the previous works. (c) 2004 Elsevier B.V. All rights reserved.