The minimum effective concentration (MEC90) of ropivacaine for ultrasound-guided caudal block in anorectal surgery. A dose finding study

被引:8
|
作者
Li, Xuehan [1 ]
Li, Jun [1 ]
Zhang, Pei [1 ]
Deng, Huifei [1 ]
Yang, Mingan [2 ]
He, Hongbo [3 ]
Wang, Rurong [1 ]
机构
[1] Sichuan Univ, Dept Anesthesiol, Lab Anesthesia & Intens Care Med, West China Hosp, Chengdu, Sichuan, Peoples R China
[2] San Diego State Univ, Div Biostat & Epidemiol, Sch Publ Hlth, San Diego, CA 92182 USA
[3] Sichuan Univ, Benign Coloproctol Dis Ctr, West China Hosp, Chengdu, Sichuan, Peoples R China
来源
PLOS ONE | 2021年 / 16卷 / 09期
基金
中国国家自然科学基金;
关键词
LOCAL ANALGESIC CONCENTRATION; EPIDURAL-ANESTHESIA; SEX-DIFFERENCES; SACRAL HIATUS; PAIN; AGE; BUPIVACAINE; CHILDREN; VOLUME; SPACE;
D O I
10.1371/journal.pone.0257283
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Caudal epidural block (CEB) provides reliable anesthesia for adults undergoing anorectal surgery. Despite the widely utilization, the minimum effective concentration for 90% patients (MEC90) of ropivacaine for CEB remains unknown. Objective To estimate MEC of ropivacaine for CEB in anorectal surgery. Design A prospective dose-finding study using biased coin design up-and-down sequential method. Setting Operating room and postoperative recovery area of Chengdu Shangjin Nanfu Hospital, from October 2019 to January 2020. Patients 50 males and 51 females scheduled for anorectal surgery. Interventions We conducted two independent biased coin design up-and down trials by genders. The concentration of ropivacaine administered to the first patient of male and female were 0.25% with fixed volume of 14ml for male and 12ml for female patients based on our previous study. In case of failure, the concentration was increased by 0.05% in the next subject. Otherwise, the next subject was randomized to a concentration 0.05% less with a probability of 0.11, or the same concentration with a probability of 0.89. Success was defined as complete sensory blockade of perineal area 15 min after the block evidenced by the presence of a lax anal sphincter and pain-free surgery. Main outcome measures The MEC of ropivacaine to achieve a successful CEB in 90%(MEC90) of the patients. Results The MEC90 of ropivacaine for CEB were estimated to be 0.35% (95% CI 0.29 to 0.4%) for male and 0.353% (95%CI 0.22 to 0.4%) for female. By extrapolation to MEC in 99% of subjects (MEC99) and pooled adjacent violators algorithm (PAVA) adjusted responses, it would be optimal to choose 0.4% ropivacaine with a volume of 14ml for male and 12ml for female. Conclusions A concentration of 0.35% ropivacaine with a volume of 14ml provided a successful CEB in 90% of the male patients, while 0.353% ropivacaine with a volume of 12ml provided a successful CEB in 90% of the female patients. A concentration of 0.4% and a volume of 14ml for male and 12 ml for female would be successful in 99% of the patients. Trial registration Chictr.org.cn identifier: No. ChiCTR 1900024315.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] The minimum effective concentration (MEC90) of ropivacaine for ultrasound-guided supraclavicular brachial plexus block
    Fang, G.
    Wan, L.
    Mei, W.
    Yu, H. H.
    Luo, A. L.
    ANAESTHESIA, 2016, 71 (06) : 700 - 705
  • [2] The minimum effective concentration (MEC90) of ropivacaine for ultrasound-guided quadratus lumborum block for analgesia after cesarean delivery: a dose finding study
    Cao, Rong
    Li, Xuehan
    Yang, Jing
    Deng, Lingmei
    Cui, Yu
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [3] The minimum effective concentration (MEC90) of ropivacaine for ultrasound-guided quadratus lumborum block for analgesia after cesarean delivery: a dose finding study
    Rong Cao
    Xuehan Li
    Jing Yang
    Lingmei Deng
    Yu Cui
    BMC Anesthesiology, 22
  • [4] The Minimum Effective Concentration (MEC95) of different volumes of ropivacaine for ultrasound-guided caudal epidural block: a dose-finding study
    Ma, Dongmei
    Chen, Yan
    Chen, Ping
    Xu, Jianhong
    Guo, Jian
    Peng, Lijia
    BMC ANESTHESIOLOGY, 2023, 23 (01)
  • [5] The Minimum Effective Concentration (MEC95) of different volumes of ropivacaine for ultrasound-guided caudal epidural block: a dose-finding study
    Dongmei Ma
    Yan Chen
    Ping Chen
    Jianhong Xu
    Jian Guo
    Lijia Peng
    BMC Anesthesiology, 23
  • [6] The minimum effective concentration (MEC90) of bupivacaine for an ultrasound-guided suprainguinal fascia iliaca compartment block for analgesia in knee surgery: a dose-finding study
    Genc, Caner
    Tulgar, Serkan
    Unal, Murat
    Genc, Ahmet Serhat
    Kehribar, Lokman
    Erdivanli, Basar
    Vermeylen, Kris
    Koksal, Ersin
    KOREAN JOURNAL OF ANESTHESIOLOGY, 2024, 77 (03) : 364 - 373
  • [7] The median effective concentration of ropivacaine for ultrasound-guided caudal block in children: a dose-finding study
    Yaqiong Tian
    Shangyingying Li
    Fei Yang
    Li Yang
    Ling Liu
    Wen Gao
    Shengfen Tu
    Journal of Anesthesia, 2024, 38 : 179 - 184
  • [8] The median effective concentration of ropivacaine for ultrasound-guided caudal block in children: a dose-finding study
    Tian, Yaqiong
    Li, Shangyingying
    Yang, Fei
    Yang, Li
    Liu, Ling
    Gao, Wen
    Tu, Shengfen
    JOURNAL OF ANESTHESIA, 2024, 38 (02) : 179 - 184
  • [9] Minimum effective volume of 0.5% ropivacaine for ultrasound-guided costoclavicular brachial plexus block A dose finding study
    Wong, Ming H.
    Karmakar, Manoj K.
    Mok, Louis Y. H.
    Songthamwat, Banchobporn
    Samy, Winnie
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (09) : 780 - 786
  • [10] Minimum effective concentration of ropivacaine for 90% ultrasound-guided axillary brachial plexus block, with or without intravenous dexamethasone
    Grelet, Tommy
    Besch, Guillaume
    Puyraveau, Marc
    Assila, Loubena
    Pascual, Mathieu
    Ferreira, David
    Vettoretti, Lucie
    Pili-Floury, Sebastien
    Samain, Emmanuel
    Berthier, Francis
    JOURNAL OF CLINICAL ANESTHESIA, 2021, 75