Simulation modelling of a micro-system for time-resolved fluorescence measurements

被引:0
|
作者
Repich, Marina [1 ,2 ]
Stoppa, David [2 ]
Rae, Bruce R. [3 ]
Henderson, Robert K. [3 ]
Dalla Betta, Gian-Franco [1 ]
机构
[1] Univ Trento, Dept Comp Sci & Informat Engn, Trento, Italy
[2] Fondazione Bruno Kessler FBK IRST, Trento, Italy
[3] Univ Edinburgh, Sch Engn, Inst Integrated Micro & Nano Syst, Edinburgh, Midlothian, Scotland
来源
关键词
Single-photon avalanche diode; time-resolved fluorescence measurement; time-correlated single photon counting; simulation modelling;
D O I
10.1117/12.853810
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the simulation modelling of a typical experimental setup for time-resolved fluorescence measurement. The developed model takes into account the setup geometry, characteristics of light source, detector and fluorescent sample as well as the adopted measurement technique. A qualitative verification of the model has been reported before. In this paper, we present a quantitative analysis and verification of the system versatility. For this we conducted time-resolved fluorescence measurements using a two-chip based micro-system, including a blue micro-LED array as a light source and a CMOS SPAD array as a detector. The sample of interest (CdSe/ZnS quantum dots in toluene) in a micro-cavity slide and an excitation filter were placed in the gap between the excitation and detection planes. A time-correlated single photon counting module was used to build fluorescence decay curves. A range of experiments with different excitation light pulse widths and using several setups have been performed. The simulated data are in good agreement with measured results and the model proves to be flexible enough to simulate different light sources and detector quenching/recharging circuits. This model can be used to predict qualitative and quantitative results for specific experimental setups, supporting the explanations of observed effects and allowing the realisation of virtual experiments.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A CMOS Time-Resolved Fluorescence Lifetime Analysis Micro-System
    Rae, Bruce R.
    Muir, Keith R.
    Gong, Zheng
    McKendry, Jonathan
    Girkin, John M.
    Gu, Erdan
    Renshaw, David
    Dawson, Martin D.
    Henderson, Robert K.
    SENSORS, 2009, 9 (11) : 9255 - 9274
  • [2] A Vertically Integrated CMOS Micro-System for Time-Resolved Fluorescence Analysis
    Rae, Bruce R.
    Muir, Keith R.
    Renshaw, David
    Henderson, Robert K.
    Girkin, John
    Gong, Zheng
    McKendry, Jonathan
    Gu, Erdan
    Dawson, Martin D.
    2009 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2009), 2009, : 80 - +
  • [3] Simulation modelling for the analysis and the optimal design of SPAD detectors for time-resolved fluorescence measurements
    Repich, Marina
    Stoppa, David
    Pancheri, Lucio
    Dalla Betta, Gian-Franco
    PHOTON COUNTING APPLICATIONS, QUANTUM OPTICS, AND QUANTUM INFORMATION TRANSFER AND PROCESSING II, 2009, 7355
  • [4] Applications of phasors to in vitro time-resolved fluorescence measurements
    Stefl, Martin
    James, Nicholas G.
    Ross, Justin A.
    Jameson, David M.
    ANALYTICAL BIOCHEMISTRY, 2011, 410 (01) : 62 - 69
  • [5] Time-Resolved Fluorescence Anisotropy Measurements Made Simple
    Peter Kapusta
    Rainer Erdmann
    Uwe Ortmann
    Michael Wahl
    Journal of Fluorescence, 2003, 13 : 179 - 183
  • [6] TIME-RESOLVED FLUORESCENCE MEASUREMENTS FOR THE CHARACTERIZATION OF EPOXY SYSTEMS
    STREHMEL, B
    STREHMEL, V
    TIMPE, HJ
    URBAN, K
    EUROPEAN POLYMER JOURNAL, 1992, 28 (05) : 525 - 533
  • [7] Time-resolved fluorescence anisotropy measurements made simple
    Kapusta, P
    Erdmann, R
    Ortmann, U
    Wahl, M
    JOURNAL OF FLUORESCENCE, 2003, 13 (02) : 179 - 183
  • [8] Miniaturized Time-Resolved Fluorescence Spectroscopy System
    Gasser, Anas
    Shcheglov, Artem
    Lapauw, Thomas
    van den Dries, Thomas
    Ingelberts, Hans
    Hoving, Willem
    Aalders, Maurice
    Kuijk, Maarten
    PHOTONIC INSTRUMENTATION ENGINEERING IX, 2022, 12008
  • [9] TIME-RESOLVED FLUORESCENCE ANISOTROPY MEASUREMENTS ON POLYVINYL AROMATIC POLYMERS)
    DRAKE, RC
    CHRISTENSEN, RL
    PHILLIPS, D
    POLYMER PHOTOCHEMISTRY, 1984, 5 (1-6): : 141 - 151
  • [10] Time-resolved fluorescence measurements of actin-phalloidin interactions
    Helms, MK
    French, T
    BIOPHYSICAL JOURNAL, 2000, 78 (01) : 443A - 443A