Deformable Image Registration of Liver With Consideration of Lung Sliding Motion

被引:26
|
作者
Xie, Yaoqin [1 ,2 ]
Chao, Ming [3 ]
Xiong, Guanglei [4 ]
机构
[1] Chinese Acad Sci, Key Lab Hlth Informat, Shenzhen Inst Adv Technol, Shenzhen 518055, Peoples R China
[2] Stanford Univ, Dept Radiat Oncol, Sch Med, Stanford, CA 94305 USA
[3] Univ Arkansas Med Sci, Dept Radiat Oncol, Little Rock, AR 72205 USA
[4] Stanford Univ, Dept Biomed Informat, Sch Med, Stanford, CA 94305 USA
基金
中国国家自然科学基金;
关键词
stereotactic body radiation therapy; four-dimensional computed tomography; deformable image registration; segmentation; liver; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; BODY RADIATION-THERAPY; STEREOTACTIC RADIOTHERAPY; TECHNICAL NOTE; ORGAN MOTION; ACCURACY; PROPAGATION; MOVEMENT; CONTOURS; CANCER;
D O I
10.1118/1.3633902
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A feature based deformable registration model with sliding transformation was developed in the upper abdominal region for liver cancer. Methods: A two-step thin-plate spline (bi-TPS) algorithm was implemented to deformably register the liver organ. The first TPS registration was performed to exclusively quantify the sliding displacement component. A manual segmentation of the thoracic and abdominal cavity was performed as a priori knowledge. Tissue feature points were automatically identified inside the segmented contour on the images. The scale invariant feature transform method was utilized to match feature points that served as landmarks for the subsequent TPS registration to derive the sliding displacement vector field. To a good approximation, only motion along superior/inferior (SI) direction of voxels on each slice was averaged to obtain the sliding displacement for each slice. A second TPS transformation, as the last step, was carried out to obtain the local deformation field. Manual identification of bifurcation on liver, together with the manual segmentation of liver organ, was employed as a "ground truth" for assessing the algorithm's performance. Results: The proposed two-step TPS was assessed with six liver patients. The average error of liver bifurcation between manual identification and calculation for these patients was less than 1.8 mm. The residual errors between manual contour and propagated contour of liver organ using the algorithm fell in the range between 2.1 and 2.8 mm. An index of Dice similarity coefficient (DSC) between manual contour and calculated contour for liver tumor was 93.6% compared with 71.2% from the conventional TPS calculation. Conclusions: A high accuracy (similar to 2 mm) of the two-step feature based TPS registration algorithm was achievable for registering the liver organ. The discontinuous motion in the upper abdominal region was properly taken into consideration. Clinical implementation of the algorithm will find broad application in radiation therapy of liver cancer. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3633902]
引用
收藏
页码:5351 / 5361
页数:11
相关论文
共 50 条
  • [1] An adaptive motion regularization technique to support sliding motion in deformable image registration
    Fu, Yabo
    Liu, Shi
    Li, H. Harold
    Li, Hua
    Yang, Deshan
    MEDICAL PHYSICS, 2018, 45 (02) : 735 - 747
  • [2] Estimation of Lung Motion Using Deformable Image Registration Based on Compressible Flow
    Li, Min
    Zhang, Limei
    Lian, Zhichao
    Xiang, Zhikang
    Xiao, Liang
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (07) : 1667 - 1670
  • [3] An implicit sliding-motion preserving regularisation via bilateral filtering for deformable image registration
    Papiez, Bartlomiej W.
    Heinrich, Mattias P.
    Fehrenbach, Jerome
    Risser, Laurent
    Schnabel, Julia A.
    MEDICAL IMAGE ANALYSIS, 2014, 18 (08) : 1299 - 1311
  • [4] A Pitfall of a Deformable Image Registration in Lung Cancer
    Sugawara, Y.
    Tachibana, H.
    Moriya, S.
    Sawant, A.
    MEDICAL PHYSICS, 2014, 41 (06) : 219 - 219
  • [5] Assessing Inter and Intrafraction Target Motion in Lung SBRT Using Deformable Image Registration
    Liang, J.
    Lack, D.
    Liu, Q.
    Sandhu, R.
    Benedetti, L.
    Stevens, C.
    Yan, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E408 - E408
  • [6] Evaluation of Deformable Image Registration for Lung Motion Estimation Using Hyperpolarized Gas Tagging MRI
    Huang, Q.
    Zhang, Y.
    Liu, Y.
    Hu, L.
    Miller, W.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [7] Automated segmentation of a motion mask to preserve sliding motion in deformable registration of thoracic CT
    Vandemeulebroucke, Jef
    Bernard, Olivier
    Rit, Simon
    Kybic, Jan
    Clarysse, Patrick
    Sarrut, David
    MEDICAL PHYSICS, 2012, 39 (02) : 1006 - 1015
  • [8] Automated Estimation of Deformable Image Registration Uncertainty in the Liver
    Zhang, Y.
    Balter, J.
    Kashani, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E188 - E188
  • [9] Dose warping performance in deformable image registration in lung
    Moriya, Shunsuke
    Tachibana, Hidenobu
    Kitamura, Nozomi
    Sawant, Amit
    Sato, Masanori
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 37 : 16 - 23
  • [10] Inelastic Deformable Image Registration (i-DIR): Capturing Sliding Motion through Automatic Detection of Discontinuities
    Andrade, Carlos I.
    Hurtado, Daniel E.
    MATHEMATICS, 2021, 9 (01) : 1 - 25