Ilizarov external fixator: acute shortening and lengthening versus bone transport in the management of tibial non-unions

被引:51
|
作者
Mahaluxmivala, J [1 ]
Nadarajah, R [1 ]
Allen, PW [1 ]
Hill, RA [1 ]
机构
[1] Princess Alexandra Hosp, Limb Reconstruct Unit, London, England
关键词
Ilizarov; circular frames; external fixator; acute shortening; bone transport; fractures; tibial; non-union; infection; deformity;
D O I
10.1016/j.injury.2004.10.027
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Eighteen patients with tibial shaft non-unions were treated by the Itizarov method between March 1995 and September 2001 by the senior author. Three subgroups of six patients each were treated by either acute shortening and lengthening, bone transport or simple stabilisation with a frame. All aspects of nonunion, infection, shortening, deformity and bone loss were addressed by using Ilizarov principles. There were 10 cases of infected non-unions in the entire series. Bone resection in the shortening group was between 3 and 6 cm (median 4.6) compared to 3-7.5 cm (median 5.9) in the bone transport group. Union was achieved in all the patients with the average time to union at 12.1 months, 17.2 months and 8.0 months, respectively. The bone transport group required additional bone grafting in five patients (83.3%) prior to union compared to one (16.7%) in the acute shortening group. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:662 / 668
页数:7
相关论文
共 50 条
  • [1] Comments on Mahaluxmivala et al. "Ilizarov external fixator: Acute shortening and lengthening versus bone transport in the management of tibial non-unions''
    Yin, Peng
    Zhang, Lihai
    Mao, Zhi
    Tang, Peifu
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (12): : 1965 - 1965
  • [2] Bone transport versus acute shortening for the management of infected tibial non-unions with bone defects
    Tetsworth, Kevin
    Paley, Dror
    Sen, Cengiz
    Jaffe, Matthew
    Maar, Dean C.
    Glatt, Vaida
    Hohmann, Erik
    Herzenberg, John E.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (10): : 2276 - 2284
  • [3] Ilizarov ring fixator in the management of infected non-unions of tibia
    Wani, Naveed Bashir
    Syed, Basit
    SICOT-J, 2015, 1
  • [4] Acute shortening versus bone transport for the treatment of infected femur non-unions with bone defects
    Sen, Cengiz
    Demirel, Mehmet
    Saglam, Yavuz
    Balci, Halil, I
    Eralp, Levent
    Kocaoglu, Mehmet
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (11): : 2075 - 2083
  • [5] Results of Ilizarov external fixator lengthening compared to lengthening and then plating in management of femoral shortening in children
    El-adly, Wael
    El-gafary, Kamal
    Khashaba, Ahmed
    Khaled, Mohamed
    ACTA ORTHOPAEDICA BELGICA, 2023, 89 (02): : 177 - 182
  • [6] Ilizarov technique: Bone transport versus bone shortening-lengthening for tibial bone and soft-tissue defects
    Wu, Yongwei
    Yin, Qudong
    Rui, Yongjun
    Sun, Zhenzhong
    Gu, Sanjun
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (02) : 341 - 345
  • [7] A STUDY OF ILIZAROV TECHNIQUE IN TREATMENT OF TIBIAL NON-UNIONS
    Kumar, Naresh
    Bendale, Mahendra
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (95): : 7009 - 7015
  • [8] Treatment of segmental tibial defects using acute bone shortening followed by gradual lengthening with circular external fixator
    Rahal, SC
    Volpi, RS
    Vulcano, LC
    JOURNAL OF VETERINARY MEDICINE SERIES A-PHYSIOLOGY PATHOLOGY CLINICAL MEDICINE, 2005, 52 (04): : 180 - 185
  • [9] Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator
    Kim, Hayoung
    Lee, Sang Ki
    Kim, Kap Jung
    Ahn, Jae Hoon
    Choy, Won Sik
    Kim, Yong In
    Koo, Jea Yun
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) : 835 - 841
  • [10] Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator
    Hayoung Kim
    Sang Ki Lee
    Kap Jung Kim
    Jae Hoon Ahn
    Won Sik Choy
    Yong In Kim
    Jea Yun Koo
    International Orthopaedics, 2009, 33 : 835 - 841