Amplified detection of DNA and analysis of single-base mismatches by the catalyzed deposition of gold on Au-nanoparticles

被引:137
|
作者
Weizmann, Y [1 ]
Patolsky, F [1 ]
Willner, I [1 ]
机构
[1] Hebrew Univ Jerusalem, Inst Chem, IL-91904 Jerusalem, Israel
关键词
D O I
10.1039/b106613g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amplification route for DNA detection based on the deposition of gold on a 10 nm Au-colloid/avidin conjugate label acting as a 'seeding' catalyst, is described. Microgravimetric quartz-crystal-microbalance measurements are employed to transduce the catalyzed deposition of gold on the piezoelectric crystals. Three different DNA detection schemes are described: (i) analysis of a 27-base nucleic acid fragment; (ii) analysis of the entire M13 phi DNA (7229 bases); and (iii) detection of a single-base mismatch in a DNA. Ultrasensitive detection of DNA is accomplished by the catalyzed deposition of gold, detection limit similar to 1 x 10(-15) M.
引用
收藏
页码:1502 / 1504
页数:3
相关论文
共 50 条
  • [1] Label-free optical detection of single-base mismatches by the combination of nuclease and gold nanoparticles
    Liu, Meiying
    Yuan, Min
    Lou, Xinhui
    Mao, Hongju
    Zheng, Dongmei
    Zou, Ruxing
    Zou, Nengli
    Tang, Xiangrong
    Zhao, Jianlong
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (11): : 4294 - 4300
  • [2] High sensitive DNA detection amplified by enlarging Au-nanoparticles in situ
    Ma, ZF
    Li, JR
    Jiang, L
    Yang, MS
    Sui, SF
    CHEMISTRY LETTERS, 2002, (03) : 328 - 329
  • [3] Visual detection of single-base mismatches in DNA using hairpin oligonucleotide with double-target DNA binding sequences and gold nanoparticles
    He, Yuqing
    Zhang, Xibao
    Zhang, Sanquan
    Kris, Mak Ka Long
    Man, Fong Chi
    Kawde, Abdel-Nasser
    Liu, Guodong
    BIOSENSORS & BIOELECTRONICS, 2012, 34 (01): : 37 - 43
  • [4] Amplified detection of single-base mismatches in DNA using micro gravimetric quartz-crystal-microbalance transduction
    Willner, I
    Patolsky, F
    Weizmann, Y
    Willner, B
    TALANTA, 2002, 56 (05) : 847 - 856
  • [5] Targeting single-base DNA mismatches with bulky metallointercalators
    Barton, JK
    Hart, JR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U2117 - U2117
  • [6] Electronic detection of single-base mismatches in DNA with ferrocene-modified probes
    Yu, CJ
    Wan, YJ
    Yowanto, H
    Li, J
    Tao, CL
    James, MD
    Tan, CL
    Blackburn, GF
    Meade, TJ
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (45) : 11155 - 11161
  • [7] Detection of all single-base mismatches in solution by chemiluminescence
    Nelson, NC
    Hammond, PW
    Matsuda, E
    Goud, AA
    Becker, MM
    NUCLEIC ACIDS RESEARCH, 1996, 24 (24) : 4998 - 5003
  • [8] Silver nanoparticles as redox reporters for the amplified electrochemical detection of the single base mismatches
    Mehrgardi, Masoud A.
    Ahangar, Laleh Enayati
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (11): : 4308 - 4313
  • [9] Nanoparticle-functionalized nucleic acids: A strategy for amplified electrochemical detection of some single-base mismatches
    Ahangar, Laleh Enayati
    Mehrgardi, Masoud A.
    ELECTROCHIMICA ACTA, 2011, 56 (06) : 2725 - 2729
  • [10] Detection of single-base DNA mutations by enzyme-amplified electronic transduction
    Patolsky, F
    Lichtenstein, A
    Willner, I
    NATURE BIOTECHNOLOGY, 2001, 19 (03) : 253 - 257