An interinstitutional comparative study and validation of computer aided drusen quantification

被引:10
|
作者
Sivagnanavel, V [1 ]
Smith, RT
Lau, GB
Chan, J
Donaldson, C
Chong, NV
机构
[1] Univ London, Univ London Kings Coll Hosp, Retinal Res Unit, London WC1E 7HU, England
[2] Columbia Univ, Dept Ophthalmol, New York, NY 10027 USA
[3] Univ London, Univ London Kings Coll Hosp, Dept Biostat Res & Dev, London WC1E 7HU, England
关键词
D O I
10.1136/bjo.2004.046813
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims: To assess the portability and clinical applicability of a software program based on Photoshop (Adobe Systems Inc, San Jose, CA, USA) for digital drusen quantification. Methods: Independent graders from the Digital Fundus Photo Reading Center of Columbia University and King's College Hospital used macular background levelling software to quantify the percentage of drusen in the central and middle Wisconsin subfields. 100 images of consecutive patients with choroidal neovascularisation in one eye and significant drusen in the other eye were analysed to determine suitability, and 10 were chosen for assessment by this software. Results: Of the 10 images used in the interinstitutional validation, the random effects ANOVA for the central and middle subfields showed a high degree of interobserver agreement. The ICC for interobserver reliability was 0.83 (95% CI: 67 to 95) for the central subfield and 0.84 (95% CI: 69 to 99) for the middle subfield. Overall agreement with the manual grading results was good and the within patient coefficient of variation was about 20% for all the pairwise comparisons between observers and the manual stereo gradings. Of the 100 images used to assess practical applicability of the software, 79 were suitable for semiautomated analysis. 13 had extensive mixed retinal pigment epithelial (RPE) changes limiting drusen identification, five had a significant number of reticular drusen, which are poorly identified by the software, and three had multiple small areas of RPE atrophy, which are difficult to distinguish from drusen. Conclusions: The software was successfully used by two institutions demonstrating portability, with good correlation between graders and to the manual stereo grading. Digital drusen quantification was possible in 79% of the images analysed.
引用
收藏
页码:554 / 557
页数:4
相关论文
共 50 条
  • [1] An inter-institutional comparative study and validation of computer-aided drusen quantification
    Chan, JWK
    Sivagnanavel, V
    Klaver, CCW
    Lau, B
    Chong, VNH
    Smith, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U295 - U295
  • [2] A Study of Computer Aided Visualization and Quantification of Emphysema
    Tan, K. L.
    Tanaka, T.
    Nakamura, H.
    Shirahata, T.
    Sugiura, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 852 - 855
  • [3] A Comparative study on computer aided liquefaction analysis methods
    Tolon, Mert
    International Journal for Housing Science and Its Applications, 2013, 37 (02): : 121 - 135
  • [4] A framework for computer-aided validation
    Drusinsky, Doron
    Michael, James Bret
    Shing, Man-Tak
    INNOVATIONS IN SYSTEMS AND SOFTWARE ENGINEERING, 2008, 4 (02) : 161 - 168
  • [5] Manual and computer-aided space analysis: A comparative study
    Schirmer, UR
    Wiltshire, WA
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1997, 112 (06) : 676 - 680
  • [6] A Comparative Study on the Machine Translation and Computer-aided Translation
    Du, Hui
    PROCEEDINGS OF 2014 2ND INTERNATIONAL CONFERENCE IN HUMANITIES, SOCIAL SCIENCES AND GLOBAL BUSINESS MANAGEMENT (ISSGBM 2014), VOL 27, 2014, 27 : 102 - 105
  • [7] Computer-aided, method for quantification of cartilage thickness and volume changes using MRL: Validation study using a synthetic model
    Kauffmann, C
    Gravel, P
    Godbout, B
    Gravel, A
    Beaudoin, G
    Raynauld, JP
    Martel-Pelletier, J
    Pelletier, JP
    de Guise, JA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (08) : 978 - 988
  • [8] Computer-aided quantification of retinal neovascularization
    A. Stahl
    K. M. Connor
    P. Sapieha
    K. L. Willett
    N. M. Krah
    R. J. Dennison
    J. Chen
    K. I. Guerin
    L. E. H. Smith
    Angiogenesis, 2009, 12 : 297 - 301
  • [9] Computer-aided quantification of retinal neovascularization
    Stahl, A.
    Connor, K. M.
    Sapieha, P.
    Willett, K. L.
    Krah, N. M.
    Dennison, R. J.
    Chen, J.
    Guerin, K. I.
    Smith, L. E. H.
    ANGIOGENESIS, 2009, 12 (03) : 297 - 301
  • [10] COMPUTER-AIDED QUANTIFICATION OF SCALP HAIR
    GIBBONS, RD
    FIEDLERWEISS, VC
    DERMATOLOGIC CLINICS, 1986, 4 (04) : 627 - 640