Evaluation of antiphospholipid antibody assays using latent class analysis to address the lack of a reference standard

被引:3
|
作者
Thaler, Markus A. [1 ]
Bietenbeck, Andreas [1 ]
Yin, Meng-Xin [2 ]
Steigerwald, Udo [3 ]
Holmes, Andrew B. [2 ]
Lindhoff-Last, Edelgard [4 ]
Luppa, Peter B. [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Inst Klin Chem & Pathobiochem, Ismaninger Str 22, D-81675 Munich, Germany
[2] Univ Melbourne, Sch Chem, Inst Bio21, Parkville, Vic, Australia
[3] Univ Klinikum Wurzburg, Zent Lab, Zentrum Innere Med A4, Wurzburg, Germany
[4] Cardioangiol Ctr Bethanien, Coagulat Res Ctr CCB, Frankfurt, Germany
基金
澳大利亚研究理事会;
关键词
antiphospholipid antibodies; biosensor; latent class analysis; method evaluation; surface plasmon resonance; ANTI-BETA2-GLYCOPROTEIN I ANTIBODIES; 13TH INTERNATIONAL-CONGRESS; EXTERNAL QUALITY-ASSURANCE; ANTICARDIOLIPIN ANTIBODIES; LABORATORY DIAGNOSIS; CLASSIFICATION CRITERIA; CLINICAL-PERFORMANCE; EUROPEAN FORUM; CONSENSUS; IGG;
D O I
10.1515/cclm-2016-0116
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Method evaluation of new assays for the detection of antiphospholipid antibodies (aPL) such as anti--cardiolipin (aCL) or anti-beta(2)-glycoprotein I (a beta(2)-GPI) is challenging, as no internationally accepted reference material is available yet. Besides a lack of standardization, unacceptable inter-laboratory comparability of established tests is regularly observed. Owing to the absence of a commonly accepted reference standard, the evaluation of two research surface plasmon resonance (SPR) biosensor assays was performed using statistical methods from latent class analysis (LCA). Methods: aCL and a beta(2)-GPI IgG and IgM were measured in sera from 63 antiphospholipid syndrome patients, fulfilling the Sydney criteria, and in 34 healthy controls with four commercial assays. LCA was performed on the results and sera were assigned to the antibody-positive or antibody- negative group. Sera were subsequently evaluated in the SPR assays for aCL and a beta(2)-GPI. Optimal cutoffs and diagnostic performances of the research systems were established employing the LCA-derived gold standard. Results: With area under the curve results of 0.96 and 0.89 for the detection of aCL and a beta(2)-GPI, the research SPR assays discriminated well between antibody-positive and antibody-negative sera. Their sensitivities and specificities were comparable to the investigated commercial immunoassays. Conclusions: SPR assays are a suitable tool for the detection of aCL and a beta(2)-GPI with diagnostic performances not different from currently available commercial tests. LCA enabled the calculation of sensitivities and specificities for aPL assays in absence of a reference standard.
引用
收藏
页码:1929 / 1937
页数:9
相关论文
共 50 条
  • [1] Evaluation of Molecular Assays for Diagnosis of Amoebic Liver Abscess in India with Bayesian Latent Class Analysis
    Ajjampur, Sitara Swarna Rao
    Mankad, Sanket
    Manuel, Malathi
    Ruth, Renita
    Prabakaran, Ashok D.
    Janagaraj, Venkateshprabhu
    David, Thambu
    Joseph, Philip
    Rupali, Priscilla
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2024, 111 (04): : 791 - 795
  • [2] Evaluating Diagnostic Tests for Helicobacter pylori Infection Without a Reference Standard: Use of Latent Class Analysis
    Jekarl, Dong Wook
    Choi, Hyunyu
    Kim, Ji Yeon
    Lee, Seungok
    Gweon, Tae Geun
    Lee, Hae Kyung
    Kim, Yonggoo
    ANNALS OF LABORATORY MEDICINE, 2020, 40 (01) : 68 - 71
  • [3] A latent class method for diagnostic tests: the new, reference, gold standard problem
    Baker, Stuart G.
    STATISTICS IN MEDICINE, 2014, 33 (24) : 4320 - 4320
  • [4] Simultaneous alleviation of verification and reference standard biases in a community-based tuberculosis screening study using Bayesian latent class analysis
    Keter, Alfred Kipyegon
    Vanobberghen, Fiona
    Lynen, Lutgarde
    Van Heerden, Alastair
    Fehr, Jana
    Olivier, Stephen
    Wong, Emily B.
    Glass, Tracy R.
    Reither, Klaus
    Goetghebeur, Els
    Jacobs, Bart K. M.
    PLOS ONE, 2024, 19 (06):
  • [5] Using data augmentation to obtain standard errors and conduct hypothesis tests in latent class and latent transition analysis
    Lanza, ST
    Collins, LM
    Schafer, JL
    Flaherty, BP
    PSYCHOLOGICAL METHODS, 2005, 10 (01) : 84 - 100
  • [6] Validation of screening instruments with an imperfect reference standard: Use of latent class analysis to estimate sensitivity and specificity.
    Pence, B. W.
    Miller, W. C.
    Gaynes, B. N.
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 2006, 163 (11) : S228 - S228
  • [7] Comparative study of Kaposi's sarcoma-associated herpesvirus serological assays using clinically and serologically defined reference standards and latent class analysis
    Nascimento, Maria Claudia
    de Souza, Vanda Akico
    Sumita, Laura Masami
    Freire, Wilton
    Munoz, Fernando
    Kim, Joseph
    Pannuti, Claudio S.
    Mayaud, Philippe
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (03) : 715 - 720
  • [8] Bayesian latent class analysis when the reference test is imperfect
    Cheung, A.
    Dufour, S.
    Jones, G.
    Kostoulas, P.
    Stevenson, M. A.
    Singanallur, N. B.
    Firestone, S. M.
    REVUE SCIENTIFIQUE ET TECHNIQUE-OFFICE INTERNATIONAL DES EPIZOOTIES, 2021, 40 (01): : 271 - 286
  • [9] Latent Class Models in Diagnostic Studies When There is No Reference Standard-A Systematic Review
    van Smeden, Maarten
    Naaktgeboren, Christiana A.
    Reitsma, Johannes B.
    Moons, Karel G. M.
    de Groot, Joris A. H.
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 2014, 179 (04) : 423 - 431
  • [10] HUMAN HEPATITIS-B ANTIBODY - EVALUATION OF ASSAYS AND DEVELOPMENT OF A REFERENCE PANEL
    WEILER, JM
    GRADY, GF
    TRANSFUSION, 1974, 14 (06) : 581 - 585