Learning metal artifact reduction in cardiac CT images with moving pacemakers

被引:9
|
作者
Lossau , T. [1 ,2 ]
Nickisch, H. [1 ]
Wissel, T. [1 ]
Morlock, M. [2 ]
Grass, M. [1 ]
机构
[1] Philips Res, Hamburg, Germany
[2] Hamburg Univ Technol, Hamburg, Germany
关键词
Cardiac CT; Metal artifact reduction; Convolutional neural network; RAY COMPUTED-TOMOGRAPHY;
D O I
10.1016/j.media.2020.101655
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Metal objects in the human heart such as implanted pacemakers frequently lead to heavy artifacts in reconstructed CT image volumes. Due to cardiac motion, common metal artifact reduction methods which assume a static object during CT acquisition are not applicable. We propose a fully automatic Dynamic Pacemaker Artifact Reduction (DyPAR+) pipeline which is built of three convolutional neural network (CNN) ensembles. In a first step, pacemaker metal shadows are segmented directly in the raw projection data by the SegmentationNets. Second, resulting metal shadow masks are passed to the InpaintingNets which replace metal-affected line integrals in the sinogram for subsequent reconstruction of a metal-free image volume. Third, the metal locations in a pre-selected motion state are predicted by the ReinsertionNets based on a stack of partial angle back-projections generated from the segmented metal shadow mask. We generate the data required for the supervised learning processes by introducing synthetic, moving pacemaker leads into 14 clinical cases without pacemakers. The SegmentationNets and the ReinsertionNets achieve average Dice coefficients of 94.16% +/- 2.01% and 55.60% +/- 4.79% during testing on clinical data with synthetic metal leads. With a mean absolute reconstruction error of 11.54 HU +/- 2.49 HU in the image domain, the InpaintingNets outperform the hand-crafted approaches PatchMatch and inverse distance weighting. Application of the proposed DyPAR+ pipeline to nine clinical test cases with real pacemakers leads to significant reduction of metal artifacts and demonstrates the transferability to clinical practice. Especially the SegmentationNets and InpaintingNets generalize well to unseen acquisition modes and contrast protocols. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Metal artifact reduction on cervical CT images by deep residual learning
    Huang, Xia
    Wang, Jian
    Tang, Fan
    Zhong, Tao
    Zhang, Yu
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [2] Metal artifact reduction on cervical CT images by deep residual learning
    Xia Huang
    Jian Wang
    Fan Tang
    Tao Zhong
    Yu Zhang
    BioMedical Engineering OnLine, 17
  • [3] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Watzke, O
    Kalender, WA
    EUROPEAN RADIOLOGY, 2004, 14 (05) : 849 - 856
  • [4] A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
    Oliver Watzke
    Willi A. Kalender
    European Radiology, 2004, 14 : 849 - 856
  • [5] Advances in metal artifact reduction in CT images: A review of traditional and novel metal artifact reduction techniques
    Selles, Mark
    van Osch, Jochen A. C.
    Maas, Mario
    Boomsma, Martijn F.
    Wellenberg, Ruud H. H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170
  • [6] Metal Artifact Reduction in CT images by Sinogram TV inpainting
    Duan, Xinhui
    Zhang, Li
    Xiao, Yongshun
    Cheng, Jianping
    Chen, Zhiqiang
    Xing, Yuxiang
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3450 - +
  • [7] Image-based metal artifact reduction in CT images
    Serifovic-Trbalic, A.
    Trbalic, A.
    2016 39TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2016, : 442 - 446
  • [8] Multiple Window Learning for CT Metal Artifact Reduction
    Niu, Chuang
    Li, Mengzhou
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIII, 2021, 11840
  • [9] Metal Artifact Reduction from CT Images Using Complementary MR Images
    Anderla, Andras A.
    Culibrk, Dubravko R.
    Delso, Gaspar
    2013 11TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS IN MODERN SATELLITE, CABLE AND BROADCASTING SERVICES (TELSIKS), VOLS 1 AND 2, 2013, : 337 - 340
  • [10] Dosimetric assessment of a novel metal artifact reduction method in CT images
    Spadea, Maria F.
    Verburg, Joost
    Baroni, Guido
    Seco, Joao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 299 - 304