Simulation of transient response of Ir-TES for position-sensitive TES with waveform domain multiplexing

被引:1
|
作者
Minamikawa, Y. [1 ,2 ]
Sato, H. [2 ]
Mori, F. [3 ]
Damayanthi, R. M. T. [3 ]
Takahashi, H. [3 ]
Ohno, M. [3 ,4 ]
机构
[1] Univ Tokyo, Dept Bioengn, Tokyo, Japan
[2] Inst Phys & Chem Res, Wako, Saitama, Japan
[3] Univ Tokyo, Dept Nucl Engn & Management, Tokyo, Japan
[4] Japan Sci & Technol Agcy, PRESTO, Tokyo, Japan
关键词
simulation; X-ray; position-sensitive; waveform domain multiplexing;
D O I
10.1007/s10909-007-9626-0
中图分类号
O59 [应用物理学];
学科分类号
摘要
We are developing a new x-ray microcalorimeter based on a superconducting transition edge sensor (TES) as an imaging sensor. Our measurement shows unique waveforms which we consider as an expression of thermal nonuniformity of TES films. This arises from the different thermal responses, so that response signal shapes would vary according to the position of the incident x-ray. This position dependency deteriorate the measured energy resolution, but with appropriate waveform analysis, this would be useful for imaging device. For more inspection, we have developed a simulation code which enables a dynamic simulation to obtain a transient response of the TES by finite differential method. Temperature and electric current distributions are calculated. As a result, we successfully obtained waveform signals. The calculated signal waveforms have similar characteristics to the measured signals. This simulation visualized the transition state of the device and will help to design better detector.
引用
收藏
页码:155 / 160
页数:6
相关论文
共 7 条
  • [1] Simulation of Transient Response of Ir-TES for Position-Sensitive TES with Waveform Domain Multiplexing
    Y. Minamikawa
    H. Sato
    F. Mori
    R. M. T. Damayanthi
    H. Takahashi
    M. Ohno
    Journal of Low Temperature Physics, 2008, 151 : 155 - 160
  • [2] Synchrotron beam test of a position-sensitive small-pixel Ir-TES array
    Mori, Fumiakira
    Minamikawa, Yasuhiro
    Damayanthi, R. M. Thushara
    Leman, Steven
    Zen, Nobuyuki
    Ohno, Masashi
    Takahashi, Hiroyuki
    Toyokawa, Hidenori
    Tanida, Hajime
    Uruga, Tomoya
    JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) : 150 - 154
  • [3] Synchrotron Beam Test of a Position-Sensitive Small-Pixel Ir-TES Array
    Fumiakira Mori
    Yasuhiro Minamikawa
    R. M. Thushara Damayanthi
    Steven Leman
    Nobuyuki Zen
    Masashi Ohno
    Hiroyuki Takahashi
    Hidenori Toyokawa
    Hajime Tanida
    Tomoya Uruga
    Journal of Low Temperature Physics, 2008, 151 : 150 - 154
  • [4] Optimised filtering for improved energy and position resolution in position-sensitive TES based X-ray detectors
    Smith, SJ
    Whitford, CH
    Fraser, GW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 556 (01): : 237 - 245
  • [5] A STUDY OF THE TRANSIENT-RESPONSE OF POSITION-SENSITIVE DETECTORS
    DUTTA, AK
    HATANAKA, Y
    SOLID-STATE ELECTRONICS, 1989, 32 (06) : 485 - 492
  • [6] POSITION DEPENDENCE OF THE TRANSIENT-RESPONSE OF A POSITION-SENSITIVE DETECTOR UNDER PERIODIC PULSED-LIGHT MODULATION
    NARAYANAN, C
    BUCKMAN, AB
    BUSCHVISHNIAC, I
    WANG, WJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (09) : 1688 - 1694
  • [7] Comprehensive simulation of the response of a silicon strip detector for position-sensitive measurements of X-rays
    Wiacek, P
    Dabrowski, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 551 (01): : 66 - 72