The effect of simulated inflammatory conditions on the corrosion of Mg, Fe and CoCrMo

被引:8
|
作者
Liu, Xiao [1 ]
Li, Wenting [2 ]
Cheng, Yan [1 ]
Zheng, Yufeng [1 ,2 ]
机构
[1] Peking Univ, Acad Adv Interdisciplinary Studies, Beijing 100871, Peoples R China
[2] Peking Univ, Sch Mat Sci & Engn, Beijing 100871, Peoples R China
基金
中国国家自然科学基金;
关键词
Biodegradable metal; Magnesium; Iron; Simulated inflammatory condition; ALLOY; DEGRADATION; MECHANISMS; MAGNESIUM; BEHAVIOR; PH;
D O I
10.1016/j.matlet.2021.131197
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For the first time, the effect of inflammation on the degradation of Mg and Fe was evaluated. The immersion test and electrochemical approaches were carried out under simulated inflammatory condition, with CoCrMo alloy selected as the reference. It turned out that H2O2, the major reactive oxygen species released in the inflammation, changed the surface film behavior of pure Mg and CoCrMo alloy for the initial exposure in PBS, but insignificantly affected their corrosion during the long-term immersion. By contrast, H2O2 actively participated in the degradation of pure Fe in a concentration-relevant manner, notably accelerated the Fe corrosion, and inhibited the corrosion product formation during 14-day immersion. It's suggested that inflammation induced corrosion should be taken into consideration in evaluating biodegradable metals.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] The effect of simulated inflammatory conditions and pH on fretting corrosion of CoCrMo alloy surfaces
    Liu, Yangping
    Gilbert, Jeremy L.
    WEAR, 2017, 390-391 : 302 - 311
  • [2] The effect of hyaluronic acid on the corrosion of an orthopedic CoCrMo-alloy in simulated inflammatory conditions
    Radice, S.
    Yao, J.
    Babauta, J.
    Laurent, M. P.
    Wimmer, M. A.
    MATERIALIA, 2019, 6
  • [3] The effect of simulated inflammatory conditions and Fenton chemistry on the electrochemistry of CoCrMo alloy
    Liu, Yangping
    Gilbert, Jeremy L.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2018, 106 (01) : 209 - 220
  • [4] A metal ion release study of CoCrMo exposed to corrosion and tribocorrosion conditions in simulated body fluids
    Espallargas, N.
    Torres, C.
    Munoz, A. I.
    WEAR, 2015, 332 : 669 - 678
  • [5] Effect of deformed subsurface on the corrosion resistance of biomedical CoCrMo alloy in simulated physiological solution
    Zhongwei Wang
    Yu Yan
    Lijie Qiao
    Journal of Materials Science, 2020, 55 : 13351 - 13362
  • [6] Effect of deformed subsurface on the corrosion resistance of biomedical CoCrMo alloy in simulated physiological solution
    Wang, Zhongwei
    Yan, Yu
    Qiao, Lijie
    JOURNAL OF MATERIALS SCIENCE, 2020, 55 (27) : 13351 - 13362
  • [7] Effect of simulated inflammatory conditions and potential on dissolution and surface oxide of CoCrMo alloy: In situ electrochemical atomic force microscopy study
    Liu, Yangping
    Gilbert, Jeremy L.
    ELECTROCHIMICA ACTA, 2018, 262 : 252 - 263
  • [8] CORROSION BEHAVIOUR OF CoCrMo AND CoCrTi ALLOYS IN SIMULATED BODY FLUIDS
    Branzoi, Ioan Viorel
    Iordoc, Mihai
    Codescu, Mirela Maria
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2007, 69 (04): : 11 - 18
  • [9] Microabrasion-corrosion of cast CoCrMo alloy in simulated body fluids
    Sun, D.
    Wharton, J. A.
    Wood, R. J. K.
    Ma, L.
    Rainforth, W. M.
    TRIBOLOGY INTERNATIONAL, 2009, 42 (01) : 99 - 110
  • [10] Corrosion stability of GO/silane in simulated inflammatory conditions as a biocompatible sealant
    Hamrahi, Behnaz
    Yarmand, Benyamin
    Massoudi, Abouzar
    MATERIALS LETTERS, 2023, 333