Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures - A prospective, randomized study of one hundred patients

被引:240
|
作者
Hardy, DCR [1 ]
Descamps, PY [1 ]
Krallis, P [1 ]
Fabeck, L [1 ]
Smets, P [1 ]
Bertens, CL [1 ]
Delince, PE [1 ]
机构
[1] Hop Univ St Pierre, Dept Orthopaed Surg, B-1000 Brussels, Belgium
来源
关键词
D O I
10.2106/00004623-199805000-00002
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One hundred elderly patients who had an intertrochanteric femoral fracture were randomized to treatment with a compression hip-screw with a plate (fifty patients) or a new intramedullary device, the intramedullary hip-screw (fifty patients). All patients were followed prospectively for one year or until death. A detailed assessment of the functional status and the plain radiographs of the hip was performed one, three, six, and twelve months postoperatively. The two treatment groups were strictly comparable. The operative time needed to insert the intramedullary hip-screw was significantly greater than that needed to insert the compression hip-screw with the plate (p = 0.02), but use of the intramedullary hip-screw was associated with less estimated intraoperative blood loss (p = 0.011). The prevalence of perioperative complications, such as bronchopneumonia, cardiac failure, and urinary tract infection, was comparable in the two treatment groups. There were one intraoperative fracture of the femoral shaft and two intraoperative fractures of the greater trochanter in the group managed with the intramedullary hip-screw. One patient had pulling-out of the compression hip-screw on the seventh postoperative day. Four patients had a trochanteric wound hematoma, without infection, after insertion of an intramedullary hip-screw All but one of the fractures healed. The one non-union, which was in a patient who had a compression hip-screw was treated with a hemiarthroplasty. The mortality rate was similar in the two treatment groups. The patients who had an intramedullary hip-screw had, on the average, significantly better mobility at one (p < 0.0001) and three months (p = 0.0013) postoperatively, This difference was no longer seen at six and twelve months, although the patients who had an intramedullary hip-screw still had significantly better walking ability outside the home at those time-periods (p = 0.05). The compression hip-screw was removed from two patients because of pain in the mid-portion of the thigh, which had begun after consolidation of the fracture. Fourteen patients who had an intramedullary hip-screw had cortical hypertrophy at the level of the tip of the nail at twelve months postoperatively, Cortical hypertrophy was significantly related to the use of two interlocking screws (p = 0.02), Six of these patients also had pain in the mid-portion of the thigh, and the nail had been locked with two screws in five of them. Three of the six patients had the hardware removed because of the pain, and the symptoms resolved. A seventh patient had pain without cortical hypertrophy. The intramedullary hip-screw device was associated with significantly less sliding of the lag-screw and subsequent shortening of the limb in the region of the thigh (p = 0.012 and 0.019, respectively); these differences were more pronounced when the unstable fractures in the two treatment groups were compared (p < 0.001).
引用
收藏
页码:618 / 630
页数:13
相关论文
共 50 条
  • [1] UNSTABLE INTERTROCHANTERIC FRACTURES OF THE HIP - TREATMENT WITH ENDER PINS COMPARED WITH A COMPRESSION HIP-SCREW
    SERNBO, I
    JOHNELL, O
    GENTZ, CF
    NILSSON, JA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (09): : 1297 - 1303
  • [2] Role of the compression screw in the dynamic hip-screw system: A finite-element study
    Chang, Chih-Wei
    Chen, Yen-Nien
    Li, Chun-Ting
    Peng, Yao-Te
    Chang, Chih-Han
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (12) : 1174 - 1179
  • [3] RESULTS OF DYNAMIC HIP-SCREW OSTEOSYNTHESIS FOR INTRACAPSULAR FRACTURES OF THE FEMORAL-NECK
    HEGGE, HGJ
    HATTEN, S
    PATKA, P
    VANMOURIK, JC
    BREEDERVELD, RS
    NETHERLANDS JOURNAL OF SURGERY, 1989, 41 (02): : 27 - 30
  • [4] Intramedullary hip screw versus sliding hip screw for unstable intertrochanteric femoral fractures in the elderly
    Harrington, P
    Nihal, A
    Singhania, AK
    Howell, FR
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2002, 33 (01): : 23 - 28
  • [5] Gotfried Percutaneous Compression Plating Compared with Sliding Hip Screw Fixation of Intertrochanteric Hip Fractures A Prospective Randomized Study
    Yang, Edward
    Qureshi, Sheeraz
    Trokhan, Shawn
    Joseph, David
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (10): : 942 - 947
  • [6] Use of the talon hip compression screw in intertrochanteric fractures of the hip
    Bramlet, DG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (425) : 93 - 100
  • [7] A prospective, randomised study comparing the percutaneous compression plate and the compression hip screw for the treatment of intertrochanteric fractures of the hip
    Peyser, A.
    Weil, Y. A.
    Brocke, L.
    Sela, Y.
    Mosheiff, R.
    Mattan, Y.
    Manor, O.
    Liebergall, M.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (09): : 1210 - 1217
  • [8] TREATMENT OF INTERTROCHANTERIC HIP FRACTURES WITH A COMPRESSION HIP SCREW AND A NAIL PLATE
    JACOBS, RR
    ARMSTRONG, HJ
    WHITAKER, JH
    PAZELL, J
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1976, 16 (08): : 599 - 603
  • [9] The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip
    Gotfried, Y
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (01): : 148 - 148
  • [10] The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip
    Kosygan, KP
    Mohan, R
    Newman, RJ
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 19 - 22