Catadioptric camera calibration using geometric invariants

被引:6
|
作者
Ying, XH [1 ]
Hu, ZY [1 ]
机构
[1] Chinese Acad Sci, Inst Automat, Natl Lab Pattern Recognit, Beijing 100080, Peoples R China
关键词
D O I
10.1109/ICCV.2003.1238647
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Central catadioptric cameras are imaging devices that use mirrors to enhance the field of view while preserving a single effective viewpoint. In this paper, we propose a novel method for the calibration of central catadioptric cameras using geometric invariants. Lines in space are projected into conics in the catadioptric image plane as well as spheres in space. We proved that the projection of a line can provide three invariants whereas the projection of a sphere can provide two. From these invariants, constraint equations for the intrinsic parameters of catadioptric camera are derived. Therefore, there are two variants of this novel method. The first one uses the projections qf lines and the second one uses the projections of spheres. In general, the projections of two lines or three spheres are sufficient to achieve the catadioptric camera calibration. One important observation in this paper is that the method based on the projections of spheres is more robust and has higher accuracy than that using the projections of lines. The performances of our method are demonstrated by the results of simulations and experiments with real images.
引用
收藏
页码:1351 / 1358
页数:8
相关论文
共 50 条
  • [1] Catadioptric camera calibration using geometric invariants
    Ying, XH
    Hu, ZY
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2004, 26 (10) : 1260 - 1271
  • [2] Geometric invariants and applications under catadioptric camera model
    Wu, YH
    Hu, ZY
    TENTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS 1 AND 2, PROCEEDINGS, 2005, : 1547 - 1554
  • [3] Unified imaging of geometric entities under catadioptric camera and camera calibration
    Duan, Huixian
    Wu, Yihong
    Jisuanji Fuzhu Sheji Yu Tuxingxue Xuebao/Journal of Computer-Aided Design and Computer Graphics, 2011, 23 (05): : 891 - 898
  • [4] Using concurrent lines in central catadioptric camera calibration
    Lei ZHANGXin DUJilin LIUDepartment of Information Science and Electronic EngineeringZhejiang UniversityHangzhou China
    JournalofZhejiangUniversity-ScienceC(Computers&Electronics), 2011, 12 (03) : 239 - 249
  • [5] Using concurrent lines in central catadioptric camera calibration
    Zhang, Lei
    Du, Xin
    Liu, Ji-lin
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE C-COMPUTERS & ELECTRONICS, 2011, 12 (03): : 239 - 249
  • [6] Using concurrent lines in central catadioptric camera calibration
    Lei Zhang
    Xin Du
    Ji-lin Liu
    Journal of Zhejiang University SCIENCE C, 2011, 12 : 239 - 249
  • [8] Calibration method for misaligned catadioptric camera
    Mashita, Tomohiro
    Iwai, Yoshio
    Yachida, Masahiko
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2006, E89D (07): : 1984 - 1993
  • [9] Catadioptric camera calibration by polarization imaging
    Morel, O.
    Seulin, R.
    Fofi, D.
    PATTERN RECOGNITION AND IMAGE ANALYSIS, PT 2, PROCEEDINGS, 2007, 4478 : 396 - +
  • [10] Noncentral catadioptric camera calibration using a generalized unified model
    Xiang, Zhiyu
    Dai, Xing
    Gong, Xiaojin
    OPTICS LETTERS, 2013, 38 (09) : 1367 - 1369