Analysis of VFTO across Bushing in 765kV Gas Insulated Substation Using EMTP Software

被引:0
|
作者
Rao, R. Durga [1 ]
Amarnath, J. [1 ]
机构
[1] JNTUHCEH, Dept EEE, Hyderabad, Andhra Pradesh, India
关键词
GIS; VFTO; EMTP; EMTP Software; FAST TRANSIENT OVERVOLTAGE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to the opening or closing of circuit breakers and disconnect switches in Gas Insulated Substations (GIS), Very Fast Transient Over-voltages (VFTO) are generated, which will bring an instantaneous change in voltage with a very short rise time and it is normally followed by oscillation having high frequencies. This paper describes the variations of VFTO magnitudes transformer bushing of a 765 kV GIS during different switching operations have been calculated and compared by using EMTP.
引用
收藏
页数:6
相关论文
共 15 条
  • [1] Estimation and Analysis of VFTO in 420kV Gas Insulated Substation
    Samikkannu, Reuban
    Annadurai, Santosh Kumar
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 165 - 172
  • [2] Electric Field Calculation and Material Optimization Of 765kV Bushing Using FEA
    AvilaPriya, F.
    Kalaiselvam, K.
    Poongothai, K.
    Arun, R.
    Prabakaran, T.
    2015 INTERNATIONAL CONFERENCE ON COMPUTATION OF POWER, ENERGY, INFORMATION AND COMMUNICATION (ICCPEIC), 2015, : 64 - 69
  • [3] Analysis of VFTO during the failure of a 550-kV gas-insulated substation
    Moreira, D. C.
    Nunes, M. V. A.
    Moreira, D. D. C.
    Costa, D. K. D.
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 189
  • [4] Computation of Very Fast Transient Overvoltages (VFTO) in a 1000 kV Gas Insulated Substation
    Haseeb, M. A.
    Thomas, M. Joy
    2017 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2017,
  • [5] E-field computation in 765kV substation using CSM with reference to occupational exposure
    Harimurugan, Devarajan
    Punekar, Gururaj S.
    Bhatt, Nagabushanam Srikanth
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (07) : 1680 - 1685
  • [6] Analysis of Partial Discharge Signals in 420 kV Gas Insulated Substation
    Prabakaran, T.
    Usa, S.
    Kumar, Santosh A.
    2013 IEEE 1ST INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (CATCON), 2013, : 249 - 254
  • [7] ESCOM'S ALPHA SUBSTATION - THE WORLD'S FIRST 765 kv GAS INSULATED SWITCHGEAR RECENTLY COMMISSIONED.
    Anon
    Elektron, 1988, 5 (01):
  • [8] Analysis of Magnitude and Rate-of-rise of VFTO in 550 kV GIS using EMTP-RV
    Seo, Hun-Chul
    Jang, Won-Hyeok
    Kim, Chul-Hwan
    Chung, Young-Hwan
    Lee, Dong-Su
    Rhee, Sang-Bong
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2013, 8 (01) : 11 - 19
  • [9] Life Cycle Assessment of a 132 kV Gas Insulated Switchgear substation using LCA methodology
    Palumberi, A. G.
    Rebolini, M.
    Bonci, P.
    Giorgi, A.
    Grasso, F.
    2018 AEIT INTERNATIONAL ANNUAL CONFERENCE, 2018,
  • [10] Modeling of 275 kV Gas Insulated Substation and Analysis and Mitigation of Very Fast Transient Overvoltages
    Shanavas, T. N.
    Krishna, Bharath K.
    Sunny, Anglight
    Anju, P. M.
    Rajeev, Aman
    2021 INTERNATIONAL CONFERENCE ON COMPUTATIONAL PERFORMANCE EVALUATION (COMPE-2021), 2021, : 810 - 814