Micro-piezoelectric immunoassay chip for simultaneous detection of Hepatitis B virus and α-fetoprotein

被引:34
|
作者
Xu, Ting [1 ]
Miao, Jianmin [1 ]
Wang, Zhihong [1 ]
Yu, Ling [2 ,3 ]
Li, Chang Ming [3 ]
机构
[1] Nanyang Technol Univ, Micromachines Ctr, Singapore 639798, Singapore
[2] Univ Pittsburgh, Dept Immunol, Pittsburgh, PA 15260 USA
[3] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 639798, Singapore
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 151卷 / 02期
关键词
Piezoelectric diaphragm; Immunoassay chip; Biosensors; HBV; Micro-machining; IMMUNOSENSOR; ANTIBODY; CRYSTAL; ANTIGEN; IMMOBILIZATION; ETIOLOGY; DEVICE; ASSAY;
D O I
10.1016/j.snb.2010.08.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a piezoelectric diaphragm-based immunoassay chip was developed to simultaneously detect anti-Hepatitis B virus (HBV) and anti-alpha-fetoprotein (AFP). The chip was fabricated by micro-machining technology and consists of eight individual circular sensors with a diameter of 800 mu m. Hepatitis B surface antigen (HBsAg), Hepatitis C core antigen (HBcAg) and AFP as the probe molecules were immobilized on different sensing spots on the chip. A solution containing anti-HBsAg and anti-AFP was applied into the reaction chambers in all sensors of the chip, and significant frequency shifts were only observed in the sensors with HBsAg and AFP for immunoassay detection. The fluorescence image further confirmed the successful detection of anti-HBsAg and anti-AFP. The total assay time was less than 2 h. The frequency shift-based calibration curves show a detection limit of 0.1 ng/ml and a dynamic detection range of 0.1-10,000 ng/ml for both anti-HBsAg and anti-AFP, respectively, thus demonstrating that the developed piezoelectric immunoassay chip has potential applications for rapid, specific, sensitive, and multiple detections of HBV. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:370 / 376
页数:7
相关论文
共 50 条
  • [1] Detection of hepatitis B virus by piezoelectric biosensor
    Zhou, XD
    Liu, LJ
    Hu, M
    Wang, LL
    Hu, JM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (1-2) : 341 - 345
  • [2] A visual DNA chip for simultaneous detection of hepatitis B virus, hepatitis C virus and human immunodeficiency virus type-1
    Wen, JK
    Zhang, XE
    Cheng, Z
    Liu, H
    Zhou, YF
    Zhang, ZP
    Yang, JH
    Deng, JY
    BIOSENSORS & BIOELECTRONICS, 2004, 19 (07): : 685 - 692
  • [3] Chemiluminescence Immunoassay for Simultaneous Detection of α-Fetoprotein and Carcinoembryonic Antigen
    Lin Jie-Hua
    Zhang Hui
    Mei Zhen-Hua
    Hu Kong-Cheng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (07) : 924 - 928
  • [4] Comparison study with enzyme immunoassay and chemiluminescence immunoassay for hepatitis B virus surface antigen detection
    Huh, Hee Jin
    Chae, Seok-Lae
    Cha, Young Joo
    KOREAN JOURNAL OF LABORATORY MEDICINE, 2007, 27 (05): : 355 - 359
  • [6] Detection of hepatitis B virus genotypes using oligonucleotide chip among hepatitis B virus carriers in Eastern China
    Tang, Xiang-Rong
    Zhang, Ji-Shen
    Zhao, Hui
    Gong, Yu-Hua
    Wang, Yong-Zhong
    Zhao, Jian-Long
    WORLD JOURNAL OF GASTROENTEROLOGY, 2007, 13 (13) : 1975 - 1979
  • [7] Oligonucleotide chip for detection of lamivudine-resistant hepatitis B virus
    Jang, H
    Cho, M
    Heo, J
    Kim, H
    Jun, H
    Shin, W
    Cho, B
    Park, H
    Kim, C
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (09) : 4181 - 4188
  • [8] ENZYME-IMMUNOASSAY FOR THE DETECTION OF HEPATITIS-B-VIRUS CORE ANTIGEN
    BUDKOWSKA, A
    KARWOWSKA, S
    JOURNAL OF IMMUNOLOGICAL METHODS, 1982, 51 (03) : 341 - 346
  • [9] Sensitive lateral flow immunoassay for the detection of hepatitis B virus surface antigen
    Martiskainen, I.
    Talha, S. M.
    Pettersson, K.
    CLINICA CHIMICA ACTA, 2019, 493 : S765 - S766
  • [10] Clinical evaluation of micro-scale chip-based PCR system for rapid detection of hepatitis B virus
    Cho, YK
    Kim, J
    Lee, Y
    Kim, YA
    Namkoong, K
    Lim, H
    Oh, KW
    Kim, S
    Han, J
    Park, C
    Pak, YE
    Ki, CS
    Choi, JR
    Myeong, HK
    Ko, C
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (11): : 2161 - 2169