Purpose: To compare computer-assisted planimetry using the Discam system (Marcher Enterprises Ltd., Hereford, UK), confocal scanning laser ophthalmoscopy (CSLO), and stereoscopic disc photography with respect to optic nerve head (ONH) measurements and glaucoma status. Design: Comparative, observational case series and interobserver variability study. Methods: Three hundred eighty-six eyes of 233 consecutive subjects were imaged with the Discam, and a subset underwent ONH evaluation with CSLO (n = 297), stereoscopic photography (n = 233), or both. Subjects were classified into normal, glaucoma suspect, and glaucoma groups based on clinical findings of slit-lamp disc examination and visual field testing. Agreement of cup-to-disc ratio measurements among the three technologies was assessed by the wintraclass correlation coefficient (ICC) and areas under the receiver operator characteristic (AROC) curves. Main Outcome Measures: Cup-to-disc ratio as measured by Discam, CSLO, and stereography. Results: Intraclass correlation coefficients calculated using the two-way random effects model for comparing Discam, CSLO, and stereography among cup-to-disc area ratio, vertical cup-to-disc ratio, and horizontal cup-to-disc ratio were 0.46 to 0.53. The ICC was higher for eyes with larger optic discs (0.51) than those with smaller ones (0.32). The ICC calculated using the fixed effects model for the Discam and CSLO comparison was 0.72. Areas under the receiver operator characteristic curves were 0.67 to 0.80 among the three technologies comparing normal with glaucomatous eyes. In general, there was no statistically significant difference between techniques with respect to sensitivity and specificity of glaucoma detection. Conclusions: There is good agreement between ONH measurements obtained by Discam, CSLO, and stereography; however, the results are not interchangeable. Similar AROC curve values among all three techniques imply that the Discam, CSLO, and stereography perform equally for the determination of glaucoma status. (C) 2003 by the American Academy of Ophthalmology.
引用
收藏
页码:1499 / 1505
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF OPTIC NERVE HEAD ASSESSMENT WITH A DIGITAL STEREO-SCOPIC CAMERA (DISCAM) SCANNING LASER OPHTHALMOSCOPY AND STERE-OGRAPHY
    A.J.Correnti
    G.Wollstein
    L.L.Price
    J.S.Schuman
    国际眼科杂志, 2003, (01) : 76 - 77
  • [2] Glaucomatous optic nerve head changes with scanning laser ophthalmoscopy
    Marengo J.
    Ucha R.A.
    Martinez-Cartier M.
    Sampaolesi J.R.
    International Ophthalmology, 2001, 23 (4-6) : 413 - 423
  • [3] Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph
    Sung, VCT
    Bhan, A
    Vernon, SA
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (02) : 196 - 202
  • [4] Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy
    Schuman, JS
    Wollstein, G
    Farra, T
    Hertzmark, E
    Aydin, A
    Fujimoto, JG
    Paunescu, LA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) : 504 - 512
  • [5] Optical Coherence Tomography/Scanning Laser Ophthalmoscopy Imaging of Optic Nerve Head Drusen
    Patel, Nandesh N.
    Shulman, Julia P.
    Chin, Kimberly J.
    Finger, Paul T.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2010, 41 (06) : 614 - 621
  • [6] En Face Optical Coherence Tomographic imaging of the optic nerve head: In vivo comparison with scanning laser ophthalmoscopy
    Oddone, F
    Tsatourian, V
    Schlottmann, PG
    Wong, HT
    Patterson, A
    Crabb, DP
    Podolenu, AGH
    Jackson, DA
    Garway-Heath, DF
    Fitzke, FW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U670 - U670
  • [7] Diagnostic Assessment of Normal and Pale Optic Nerve Heads by Confocal Scanning Laser Ophthalmoscope and Stereophotography
    Fogagnolo, Paolo
    Romano, Simona
    Ranno, Stefano
    Taibbi, Giovanni
    Pierrottet, Chiara
    Ferreras, Antonio
    Figus, Michele
    Rossetti, Luca
    Orzalesi, Nicola
    JOURNAL OF GLAUCOMA, 2011, 20 (01) : 10 - 14
  • [8] Visualisation of deep buried drusen of the optic nerve head with scanning laser ophthalmoscopy using the infrared laser
    Maier, M
    Ugi, I
    Obermaier, M
    VISION RESEARCH, 1996, 36 : 417 - 417
  • [9] The "ISN'T Rule" in Healthy Participant Optic Nerve Head by Confocal Scanning Laser Ophthalmoscopy
    Iester, Michele
    Bertolotto, Marina
    Recupero, Santo M.
    Perdicchi, Andrea
    JOURNAL OF GLAUCOMA, 2011, 20 (06) : 350 - 354
  • [10] Scanning laser ophthalmoscopy of the optic nerve head in exfoliation glaucoma and ocular hypertension with exfoliation syndrome
    Harju, M
    Vesti, E
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (03) : 297 - 303