Ultrasound-guided lumbar plexus block using three different techniques: a comparison of ultrasound image quality

被引:12
|
作者
Sato, Makoto [1 ]
Sasakawa, Tomoki [1 ]
Izumi, Yuki [1 ]
Onodera, Yoshiko [1 ]
Kunisawa, Takayuki [1 ]
机构
[1] Asahikawa Med Univ, Dept Anesthesiol & Crit Care Med, Higashi Ku, 2-1-1-1 Midorigaoka, Asahikawa, Hokkaido 788510, Japan
关键词
Local anesthetics; Lumbar plexus; Nerve block; Ultrasound; VOLUNTEERS; NERVE;
D O I
10.1007/s00540-018-2539-z
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose The purpose of this study was to compare the ultrasound image quality at three different transducer positions for ultrasound-guided lumbar plexus block (LPB). Methods This prospective comparative study included 30 patients who underwent total hip arthroplasty under general anesthesia in combination with LPB. Using the same ultrasound machine settings for each patient, a transverse view of the lumbar plexus (LP) at the L3-4 vertebral level was obtained with a convex transducer placed at three different positions: immediately lateral to the dorsal midline (medial position), almost 5 cm lateral to the dorsal midline (paravertebral position), and at the abdominal transverse flank (shamrock position). Ultrasound-guided LPB with catheter insertion was performed via in-plane needle insertion with the transducer randomly assigned to one of the three positions. The echo intensity (EI) ratio of the LP to psoas major muscle (PMM), the EI of the LP and PMM, and the ultrasound visibility score of the needle, local anesthetic, and catheter were recorded. Results The LP/PMM EI ratio was significantly higher at paravertebral position (1.4 +/- 0.2) than at medial position (1.2 +/- 0.2; p = 0.003) and shamrock position (1.3 +/- 0.2; p = 0.040). The EI of the LP and PMM was highest at shamrock position (p < 0.001). During the block procedure, the ultrasound visibility score of the needle and local anesthetic was significantly higher at paravertebral position than at medial position. Conclusion Under the conditions of this study, the contrast between LP and PMM is significantly higher at paravertebral position than at medial position and at the abdominal transverse flank (shamrock position). LP and PMM at the shamrock position appear significantly brighter among the three probe positions in sonograms.
引用
收藏
页码:694 / 701
页数:8
相关论文
共 50 条
  • [1] Ultrasound-guided lumbar plexus block using three different techniques: a comparison of ultrasound image quality
    Makoto Sato
    Tomoki Sasakawa
    Yuki Izumi
    Yoshiko Onodera
    Takayuki Kunisawa
    Journal of Anesthesia, 2018, 32 : 694 - 701
  • [2] A new approach for ultrasound-guided lumbar plexus block: ultrasound-guided paravertebral LPB
    Tsuda, Yukiyoshi
    Myoga, Yoshinori
    Chijiiwa, Eriko
    Kinoshita, Atsuko
    Kubota, Ryo
    MINERVA ANESTESIOLOGICA, 2023, 89 (05) : 487 - 489
  • [3] Superiority of ultrasound-guided Shamrock lumbar plexus block
    Nielsen, Martin V.
    Bendtsen, Thomas F.
    Borglum, Jens
    MINERVA ANESTESIOLOGICA, 2018, 84 (01) : 115 - 121
  • [4] Ultrasound-guided Lumbar Plexus Block in Supine Position
    Liu, Yong
    Ke, Xijian
    Wu, Xi
    Mei, Wei
    ANESTHESIOLOGY, 2018, 128 (04) : 812 - 812
  • [5] Ultrasound-guided lumbar plexus block through the acoustic window of the lumbar ultrasound trident
    Karmakar, M. K.
    Ho, A. M. -H.
    Li, X.
    Kwok, W. H.
    Tsang, K.
    Kee, W. D. Ngan
    BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (04) : 533 - 537
  • [6] Randomized prospective study of three different techniques for ultrasound-guided axillary brachial plexus block
    Cunha Ferraro, Leonardo Henirque
    Takeda, Alexandre
    Castello Branco de Sousa, Paulo Cesar
    Gomes Mehlmann, Fernanda Moreira
    Mitsunaga Junior, Jorge Kiyoshi
    dos Reis Falcao, Luiz Fernando
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2018, 68 (01): : 62 - 68
  • [7] Flow dynamics of ultrasound-guided lumbar plexus block in adults
    Diwan, Sandeep
    Nair, Abhijit
    Gawai, Nitin
    Sancheti, Parag
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2021, 37 (04) : 565 - 568
  • [8] A study of the paravertebral anatomy for ultrasound-guided posterior lumbar plexus block
    Kirchmair, L
    Entner, T
    Wissel, J
    Moriggl, B
    Kapral, S
    Mitterschiffthaler, G
    ANESTHESIA AND ANALGESIA, 2001, 93 (02): : 477 - 481
  • [9] Ultrasound-guided lumbar plexus block in volunteers; a randomized controlled trial
    Strid, J. M. C.
    Sauter, A. R.
    Ullensvang, K.
    Andersen, M. N.
    Daugaard, M.
    Bendtsen, M. A. F.
    Soballe, K.
    Pedersen, E. M.
    Borglum, J.
    Bendtsen, T. F.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (03) : 430 - 438
  • [10] Ultrasound-guided pediatric continuous lumbar plexus block: The hanging needle technique
    Tognu, Andrea
    Pacini, Ilaria
    JOURNAL OF CLINICAL ANESTHESIA, 2020, 67