An accurate PSF model with few parameters for axially shift-variant deconvolution

被引:13
|
作者
Aguet, Francois [1 ]
Van De Ville, Dimitri [1 ]
Unser, Michael [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Biomed Imaging Grp, CH-1015 Lausanne, Switzerland
关键词
deconvolution; fluorescence microscopy; maximum-likelihood; point spread function;
D O I
10.1109/ISBI.2008.4540956
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate knowledge of an imaging system's point spread function (PSF) is crucial for successful deconvolution. For fluorescence microscopy, PSF estimations based on either theoretical models or experimental measurements are available. However, due to the axially shift-variant nature of the PSF, neither method guarantees an estimate that is valid for the entire object space. In this work, we present a reduced-parameter version of a state-of-the-art theoretical model. We give a maximum-likelihood based algorithm for the estimation of its parameters, and we show how a fit of our model to two axially isolated point source measurements in an experimental setup can be used to accurately reproduce measured PSFs within the entire specimen.
引用
收藏
页码:157 / 160
页数:4
相关论文
共 12 条
  • [1] DOA Estimation of Arc Arrays Using Deconvolution with Shift-Variant PSF
    Duan, Wenjun
    Sun, Chao
    Liu, Xionghou
    Wu, Jingrong
    Fan, Kuan
    GLOBAL OCEANS 2020: SINGAPORE - U.S. GULF COAST, 2020,
  • [2] Shift-Variant Blind Deconvolution Using a Field of Kernels
    Sonogashira, Motoharu
    Iiyama, Masaaki
    Minoh, Michihiko
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2017, E100D (09) : 1971 - 1983
  • [3] Deconvolution of shift-variant broadening for Compton scatter imaging
    Evans, BL
    Martin, JB
    Roggemann, MC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 661 - 666
  • [4] A new and general method for blind shift-variant deconvolution of biomedical images
    Blume, Moritz
    Zikic, Darko
    Wein, Wolfgang
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2007, PT 1, PROCEEDINGS, 2007, 4791 : 743 - +
  • [5] SHIFT-VARIANT NON-NEGATIVE MATRIX DECONVOLUTION FOR MUSIC TRANSCRIPTION
    Kirchhoff, Holger
    Dixon, Simon
    Klapuri, Anssi
    2012 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2012, : 125 - 128
  • [6] Shift-variant deconvolution for aperture correction of collimator in emission CT. Experimental verification
    Paek, Seungkuen
    Nakajima, Masato
    Morozumi, Tatsuru
    Yuta, Shin'ichi
    Systems and Computers in Japan, 1990, 21 (02): : 56 - 64
  • [7] Efficient shift-variant image restoration using deformable filtering (Part II): PSF field estimation
    David Miraut
    Johannes Ballé
    Javier Portilla
    EURASIP Journal on Advances in Signal Processing, 2012
  • [8] Efficient shift-variant image restoration using deformable filtering (Part II): PSF field estimation
    Miraut, David
    Balle, Johannes
    Portilla, Javier
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2012, : 1 - 19
  • [9] MRF model-based identification of shift-variant point spread function for a class of imaging systems
    Department of Electrical Engineering, Indian Inst. Technol., P., Bombay, India
    Signal Process, 3 (285-299):
  • [10] MRF model-based identification of shift-variant point spread function for a class of imaging systems
    Rajagopalan, AN
    Chaudhuri, S
    SIGNAL PROCESSING, 1999, 76 (03) : 285 - 299