Double distortion correction method in a catadioptric vision system with a conic mirror

被引:4
|
作者
Zhou, Fuqiang [1 ]
Chen, Xin [1 ]
Tan, Haishu [2 ]
机构
[1] Beihang Univ, Minist Educ, Key Lab Precis Optomechatron Technol, Beijing 100191, Peoples R China
[2] Foshan Univ, Dept Elect Informat Engn, Foshan 528000, Peoples R China
基金
中国国家自然科学基金;
关键词
PANORAMIC IMAGE; DESIGN; LENS; CALIBRATION; ALGORITHM;
D O I
10.1364/JOSAA.34.001651
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Because of the low calibration precision caused by reflector distortion in catadioptric vision systems with conic mirrors, we proposed a double distortion correction model based on the panoramic image rectification. The lens distortion and the reflector distortion are analyzed independently in the mathematic model of the double distortion correction. Moreover, the modified model in this paper added the trigonometric functions into the polynomial model to solve the combined distortion. Additionally, extensive experiments, both simulative and real data, have been carried out and show that the proposed model achieves comparable measurement accuracy in contrast with the traditional distortion method. (C) 2017 Optical Society of America
引用
收藏
页码:1651 / 1658
页数:8
相关论文
共 50 条
  • [1] Calibration of a catadioptric omnidirectional vision system with conic mirror
    Marcato Junior, J.
    Tommaselli, A. M. G.
    Moraes, M. V. A.
    ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2016, 113 : 97 - 105
  • [2] Double-mirror catadioptric sensors with ultrawide field of view and no distortion
    Koese, Emek
    Perline, Ron K.
    APPLIED OPTICS, 2014, 53 (04) : 528 - 536
  • [3] An Omnidirectional Vision Sensor Based on a Spherical Mirror Catadioptric System
    Barone, Sandro
    Carulli, Marina
    Neri, Paolo
    Paoli, Alessandro
    Razionale, Armando Viviano
    SENSORS, 2018, 18 (02)
  • [4] Catadioptric stereo-vision system using a spherical mirror
    Barone, S.
    Neri, P.
    Paoli, A.
    Razionale, A. V.
    AIAS2017 - 46TH CONFERENCE ON STRESS ANALYSIS AND MECHANICAL ENGINEERING DESIGN, 2018, 8 : 83 - 91
  • [5] Radial distortion correction in a vision system
    Wang, Qiyue
    Wang, ZhongYu
    Smith, Tim
    APPLIED OPTICS, 2016, 55 (31) : 8876 - 8883
  • [6] Aberration correction method for the catadioptric imaging system design
    Liu, Zhenjie
    Yu, Feihong
    APPLIED OPTICS, 2016, 55 (11) : 2943 - 2950
  • [7] Research on Conic Curve Fitting in Central Catadioptric System
    Li, Ruifeng
    Wang, Liangliang
    Wang, Ke
    2013 INTERNATIONAL CONFERENCE ON ADVANCED MECHATRONIC SYSTEMS (ICAMECHS), 2013, : 390 - 395
  • [8] Calibration method for misaligned catadioptric camera based on planar conic
    Zhu, Qidan
    Xu, Congying
    Cai, Chengtao
    FIFTH INTERNATIONAL CONFERENCE ON MACHINE VISION (ICMV 2012): COMPUTER VISION, IMAGE ANALYSIS AND PROCESSING, 2013, 8783
  • [9] Independent distortion correction algorithm in vision measurement system
    Tang, Wei
    Ye, Dong
    Yuan, Feng
    Chen, Gang
    Guangdianzi Jiguang/Journal of Optoelectronics Laser, 2013, 24 (02): : 308 - 315
  • [10] APOCHROMATIC CATADIOPTRIC SYSTEM EQUIVALENT TO PARABOLIC MIRROR
    CHURILOVSKII, VN
    GOLDIS, KI
    APPLIED OPTICS, 1964, 3 (07): : 843 - &