Monitoring antimicrobial resistance (AMR) using CUSUM control charts

被引:1
|
作者
Righi, L. [1 ,2 ,3 ]
Amarsy, R. [4 ,5 ]
Picat, M. -Q. [2 ]
Thuillier, M. [2 ]
Cambau, E. [5 ,6 ]
Raskine, L. [4 ,5 ]
Chevret, S. [2 ,7 ]
Flicoteaux, R. [2 ,7 ]
机构
[1] Postgrad Sch Publ Hlth, Siena, Italy
[2] St Louis Hosp, AP HP, Biostat & Med Informat Team, Paris, France
[3] Univ Hosp Geneva, Qual Care Serv, Chemin Thury 3, CH-1206 Geneva, Switzerland
[4] Lariboisiere Hosp, AP HP, Infect Control Unit, Paris, France
[5] Hop Univ St Louis Lariboisiere Fernand Widal, Lariboisiere Hosp, AP HP, Bacteriol, Paris, France
[6] Paris Diderot Univ, Inserm UMR 1137, IAME, Sorbonne Paris Cite, Paris, France
[7] Paris Diderot Univ, ECSTRA Team, Sorbonne Paris Cite, Inserm UMR 1153,Epidemiol & Biostat Sorbonne Pari, Paris, France
关键词
LACTAMASE-PRODUCING ENTEROBACTERIACEAE; HAND HYGIENE; CARE; OUTCOMES;
D O I
10.1007/s10096-017-2961-4
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
We evaluated the use of the Cumulative Summation (CUSUM) control chart methodology for detection of an excessive increase in antimicrobial-resistant (AMR) bacteria acquisition. We used administrative, clinical and bacteriological data from all 157,570 patients hospitalized for at least 48 h from January 1, 2010 to December 31, 2015 in a 654-bed university teaching hospital in Paris, France. Monthly computed CUSUM were evaluated for the detection of out-of-control situations, defined as incidence rates of acquired AMR bacterial colonization exceeding acceptable thresholds at the hospital and ward levels (based on six selected wards) for AMR bacteria overall and Extended-spectrum beta-lactamases Enterobacteriaceae (ESBL-E) and Methicillin-resistant Staphylococcus aureus (MRSA), specifically. During the study period, 1,403 samples of acquired AMR bacteria were identified including 1,129 ESBL-E and 151 MRSA. The incidence rate of acquired AMR bacteria was stable at the hospital and the wards level. When based on AMR bacteria overall, CUSUM alarms were triggered at the hospital level and at the ward level in four units. For ESBL-E, CUSUM tests generated alarms at the hospital level and for the same four wards, and for MRSA, CUSUM tests detected out-of-control situations in all the wards. The CUSUM approach appears complementary with hospital infection control strategies currently in practice and appears of interest in common practice as a simple tool for AMR surveillance.
引用
收藏
页码:1519 / 1525
页数:7
相关论文
共 50 条
  • [1] Monitoring antimicrobial resistance (AMR) using CUSUM control charts
    L. Righi
    R. Amarsy
    M.-Q. Picat
    M. Thuillier
    E. Cambau
    L. Raskine
    S. Chevret
    R. Flicoteaux
    European Journal of Clinical Microbiology & Infectious Diseases, 2017, 36 : 1519 - 1525
  • [2] Monitoring Digital Technologies in Hydraulic Systems Using CUSUM Control Charts
    Breidi, Farid
    Chehade, Abdallah
    Lumkes, John
    PROCEEDINGS OF THE ASME/BATH SYMPOSIUM ON FLUID POWER AND MOTION CONTROL, 2019, 2020,
  • [3] A Bayesian way of monitoring the linear profiles using CUSUM control charts
    Abbas, Tahir
    Ahmad, Shabbir
    Riaz, Muhammad
    Qian, Zhengming
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 2019, 48 (01) : 126 - 149
  • [4] CUSUM control charts for monitoring optimal portfolio weights
    Golosnoy, Vasyl
    Ragulin, Sergiy
    Schmid, Wolfgang
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2011, 55 (11) : 2991 - 3009
  • [5] Monitoring the coefficient of variation using variable sampling interval CUSUM control charts
    Tran, P. H.
    Heuchenne, C.
    JOURNAL OF STATISTICAL COMPUTATION AND SIMULATION, 2021, 91 (03) : 501 - 521
  • [6] Adaptive CUSUM control charts for efficient monitoring of process dispersion
    Zaman, Babar
    QUALITY AND RELIABILITY ENGINEERING INTERNATIONAL, 2022, 38 (05) : 2273 - 2302
  • [7] Condition monitoring based on modified CUSUM and EWMA control charts
    Fernando da Silva Lampreia, Suzana Paula Gomes
    Gomes Requeijo, Jose Fernando
    Mendonca Dias, Jose Antonio
    Vairinhos, Valter Martins
    Soares Barbosa, Patricia Isabel
    JOURNAL OF QUALITY IN MAINTENANCE ENGINEERING, 2018, 24 (01) : 119 - 132
  • [8] Efficient CUSUM control charts for monitoring the multivariate coefficient of variation
    Hu, XueLong
    Zhang, SuYing
    Zhang, Jing
    Saghir, Aamir
    COMPUTERS & INDUSTRIAL ENGINEERING, 2023, 179
  • [9] Parabolic CUSUM control charts
    Wiklund, SJ
    COMMUNICATIONS IN STATISTICS-SIMULATION AND COMPUTATION, 1997, 26 (01) : 107 - 123
  • [10] Cusum charts for monitoring an autocorrelated process
    Lu, CW
    Reynolds, MR
    JOURNAL OF QUALITY TECHNOLOGY, 2001, 33 (03) : 316 - 334