Decomposition of the Cardiac and Respiratory Components from Impedance Pneumography Signals

被引:13
|
作者
Mlynczak, Marcel [1 ]
Cybulski, Gerard [1 ,2 ]
机构
[1] Warsaw Univ Technol, Fac Mechatron, Inst Metrol & Biomed Engn, Boboli 8, PL-02525 Warsaw, Poland
[2] Polish Acad Sci, Mossakowski Med Res Ctr, Dept Appl Physiol, Pawinskiego 5, PL-02106 Warsaw, Poland
关键词
Ambulatory Monitoring; Impedance Pneumography; Cardiorespiratory Activity; Decomposition; CARDIOGENIC OSCILLATIONS; SPLINE FUNCTIONS;
D O I
10.5220/0006107200260033
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Impedance pneumography (IP) measures changes of thoracic electrical impedance connected with change of the air volume in the lungs. The electrode configuration used in IP applications causes that electrical heart activity is visible in the IP signals. The aim of this paper is to assess the opportunity to decompose both respiratory and cardiac components and its quality using various methods. Ten students performed static breathing sequences, intended both for calibration and testing. Our prototype, Pneumonitor 2, and the reference pneumotachometer, were used. The accuracy of calculating tidal volume and heart rate, the calibration procedure and the time of analysis, were considered. Mean 86.5% accuracy of tidal volume calculating and only 2.7% error of heart rate estimation were obtained using moving average smoothing filters, for simple short recording of free breathing calibration procedure, in three body positions. More sophisticated adaptive filtering also provided good accuracy, however the processing time was 100-times higher, compared to simple methods. It seems impedance pneumography, without ECG, could be enough for measuring basic cardiorespiratory activity, particularly during ambulatory recordings, in which the least disturbing equipment is desirable.
引用
收藏
页码:26 / 33
页数:8
相关论文
共 50 条
  • [1] Decomposition method of an electrical bio-impedance signal into cardiac and respiratory components
    Krivoshei, A.
    Kukk, V.
    Min, M.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (06) : S15 - S25
  • [2] Ambulatory impedance pneumography device for quantitative monitoring of volumetric parameters in respiratory and cardiac applications
    Mlynczak, Marcel C.
    Niewiadomski, Wiktor
    Zylinski, Marek
    Cybulski, Gerard P.
    2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 965 - 968
  • [3] Improvement of Body Posture Changes Detection during Ambulatory Respiratory Measurements Using Impedance Pneumography Signals
    Mlynczak, M.
    Cybulski, G.
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 167 - 171
  • [4] Artefact Detection in Impedance Pneumography Signals: A Machine Learning Approach
    Moeyersons, Jonathan
    Morales, John
    Seeuws, Nick
    Van Hoof, Chris
    Hermeling, Evelien
    Groenendaal, Willemijn
    Willems, Rik
    Van Huffel, Sabine
    Varon, Carolina
    SENSORS, 2021, 21 (08)
  • [5] Comparison of thoracic impedance pneumography and inductive plethysmography in the assessment of respiratory function
    Wilson, Stephen
    Kaiser, Robert
    Holzgrefe, Henry
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2013, 68 (01) : E44 - E44
  • [6] Development of Portable Device to Measure Respiratory Activity Based on Impedance Pneumography
    Canadas, G. E.
    Dell'Aquila, C. R.
    Laciar, E.
    II LATIN AMERICAN CONFERENCE ON BIOIMPEDANCE, 2016, 54 : 60 - 63
  • [7] Comparison of thoracic impedance pneumography and inductive plethysmography in the assessment of respiratory function
    Wilson, Stephen E.
    Tichenor, Stephen D.
    Norton, Kevin
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2012, 66 (02) : 198 - 198
  • [8] Evaluation of Respiratory Signal Record Based on Impedance Pneumography and Textile Electrodes
    Ruben Dell'Aquila, Carlos
    Eduardo Canadas, Gabriel
    Laciar, Eric
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 1502 - 1509
  • [9] IMPEDANCE PNEUMOGRAPHY - COMPARISON BETWEEN CHEST IMPEDANCE CHANGES AND RESPIRATORY VOLUMES IN 11 HEALTHY VOLUNTEERS
    GRENVIK, A
    BALLOU, S
    SAFAR, P
    MILLEN, JE
    MCGINLEY, E
    COOLEY, WL
    CHEST, 1972, 62 (04) : 439 - &
  • [10] Comparison of simple algorithms for estimating respiration rate from electrical impedance pneumography signals in wearable devices
    Jeyhani V.
    Vuorinen T.
    Mäntysalo M.
    Vehkaoja A.
    Health and Technology, 2017, 7 (1) : 21 - 31