Diagnostic value of multi-slice spiral computed tomography after adiponectin treatment of tracheal malignancies

被引:0
|
作者
Liu, Jian [1 ]
Zu, Degui [2 ]
Yang, Ying [1 ]
Deng, Maosong [1 ]
Deng, Gang [1 ]
Chang, Xin [1 ]
Yin, Xiaoming [1 ]
机构
[1] Dept Radiol, Beijing, Peoples R China
[2] Emergency Gen Hosp, Dept Intervent, Beijing, Peoples R China
关键词
Multi-slice spiral CT; Adiponectin; Tracheal malignancy; Computed tomography (CT); PET/CT;
D O I
10.4314/tjpr.v21i10.22
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: To determine the diagnostic value of multi-slice spiral computed tomography (CT) after adiponectin treatment of tracheal malignancies.Methods: Sixty patients with tracheal malignancies admitted to Emergency General Hospital from February 2017 to February 2021 were assigned to the study group. After physical examination, 60 healthy subjects in the same period served as the control group. All patients were treated with adiponectin. The control group was subjected to serum tumor marker testing before and after treatment, while the study group received multi-slice spiral CT before and after adiponectin treatment.Results: The 60 patients enrolled in the study group comprised 30 cases of squamous carcinoma, 22 cases of adenocarcinoma, and 8 cases of mucosa-associated lymphoma. Multi-slice spiral CT before treatment showed that 35 patients with tracheal malignant tumors had expansive lumen hyperplasia, while 25 patients with bulging tumors had saddle-like hyperplasia with irregular surfaces, uneven margins, and mean thickness of 5.96 +/- 0.65 mm in the tracheal and bronchial walls adjacent to the luminal nodule. After treatment, the thickness of the tracheal and bronchial walls adjacent to the luminal nodule decreased to a mean value of 4.65 +/- 0.48 mm. Prior to treatment, the mean enhancement value of contrast-enhanced CT was 18.98 +/- 1.23 Hu, and mean tumor diameter was 3.68 +/- 0.23 cm. However, after treatment, the mean enhancement value increased to 25.98 +/- 1.44 Hu, while mean tumor diameter decreased to 2.54 +/- 0.20 cm in the study group.Conclusion: Multi-slice spiral CT has promising diagnostic value for patients with tracheal malignancies after adiponectin treatment. Therefore, it can potentially be used in the diagnosis of patients with tracheal malignancies.
引用
收藏
页码:2203 / 2209
页数:7
相关论文
共 50 条
  • [1] The diagnostic value of multi-slice spiral computed tomography in patients with renal carcinoma
    Liu, Jie
    Yang, Shufang
    Jin, Haiying
    He, Xiang
    Nie, Peng
    Wang, Changfu
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (04) : 795 - 798
  • [2] Diagnostic value of multi-slice spiral computed tomography angiography for intracranial aneurysm
    Yan, Jilai
    NEUROLOGICAL SCIENCES, 2024, 45 (08) : 3901 - 3905
  • [3] Diagnostic Value of Multi-Slice Spiral Computed Tomography for Bronchial Dysplasia in Premature Infants
    Zhang, Weiwei
    Wang, Shaohua
    MEDICAL SCIENCE MONITOR, 2018, 24 : 7375 - 7381
  • [4] Assessment of diagnostic value of ultrasound and multi-slice spiral computed tomography in acute appendicitis: a retrospective study
    Lu, Kai
    Zhong, Furui
    Miao, Juan
    Sun, Chong
    Zhou, Kaibo
    Wang, Wei
    Zhang, Faqiang
    Yang, Hua
    Lan, Ke
    ABDOMINAL RADIOLOGY, 2025, 50 (03) : 1117 - 1122
  • [5] Multi-slice spiral computed tomography in clinical cardiology
    Beck, T
    Burgstahler, C
    Küttner, A
    Heuschmid, M
    Kopp, AF
    Schröder, S
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2004, 129 (47) : 2543 - 2546
  • [6] Bezoar-induced small bowel obstruction: Clinical characteristics and diagnostic value of multi-slice spiral computed tomography
    Wang, Pei-Yuan
    Wang, Xia
    Zhang, Lin
    Li, Hai-Fei
    Chen, Liang
    Wang, Xu
    Wang, Bin
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (33) : 9774 - 9784
  • [7] Bezoar-induced small bowel obstruction: Clinical characteristics and diagnostic value of multi-slice spiral computed tomography
    Pei-Yuan Wang
    Xia Wang
    Lin zhang
    Hai-Fei Li
    Liang Chen
    Xu Wang
    bin Wang
    World Journal of Gastroenterology, 2015, (33) : 9774 - 9784
  • [8] Diagnostic value of multi-slice spiral CT in aortic dissection
    刘昌伟
    黄向明
    符水
    SouthChinaJournalofCardiology, 2010, 11 (04) : 234 - 237
  • [9] Diagnostic and Management Value of Multi-Slice Computed Tomography in Esophageal Jujube Pit Impaction
    Liu, Jun-Hua
    Dong, Zhong-Xing
    Cui, Jie
    Yan, Ru-Yi
    Zheng, Dong
    Wang, Xiao-Ying
    Xu, Kai
    Zhao, Yang
    ENT-EAR NOSE & THROAT JOURNAL, 2024,
  • [10] Single- and multi-slice spiral computed tomography of the paediatric kidney
    Puig, S
    Schaefer-Prokop, C
    Mang, T
    Prokop, M
    EUROPEAN JOURNAL OF RADIOLOGY, 2002, 43 (02) : 139 - 145