Measurement of total CO2 in microliter samples of urine and other biological fluids using infrared detection of CO2

被引:14
|
作者
Trepiccione, Francesco [1 ,2 ]
Iena, Francesco Maria [1 ,3 ]
Catalini, Laura [1 ,3 ]
Carpi, Francesco Martino [1 ,3 ]
Koed, Mogens [1 ]
Frische, Sebastian [1 ]
机构
[1] Univ Aarhus, Dept Biomed, Vilh Meyers Alle 3,Univ Pk,Bygn 1233, DK-8000 Aarhus, Denmark
[2] Univ Campania Luigi Vanvitelli, Dept Cardiothorac & Resp Sci, Naples, Italy
[3] Univ Camerino, Sch Biosci & Vet Med, Camerino, Italy
来源
基金
新加坡国家研究基金会;
关键词
Acid/base status; Bicarbonate; NDIR; Urine; Total CO2; TOTAL CARBON-DIOXIDE; NANOLITER SAMPLES; BLOOD; BICARBONATE; PLASMA; PH;
D O I
10.1007/s00424-017-1997-8
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of this study is to describe a low-cost and simply made instrument capable of measuring the total CO2 content of microliter volumes of biological fluids utilizing a commercially available CO2 sensor based on a NDIR detector. The described instrument is based on transformation of dissolved HCO3 (-) to CO2 by acidification and subsequent measurement of the produced CO2. The instrument has a linear response in the range 0.025-10 mu mol HCO3 (-), which enables measurements in fresh urine and plasma samples down to 5 mu l. The values from plasma were compared to measurements made on 65 mu l whole blood in an automatic blood gas analyzer and found not to differ significantly. Compared to currently commercially available instruments applying the same principles to measure total CO2, this study provides a simple and robust alternative which even can be used on smaller sample volumes.
引用
收藏
页码:1267 / 1275
页数:9
相关论文
共 50 条
  • [1] Measurement of total CO2 in microliter samples of urine and other biological fluids using infrared detection of CO2
    Francesco Trepiccione
    Francesco Maria Iena
    Laura Catalini
    Francesco Martino Carpi
    Mogens Koed
    Sebastian Frische
    Pflügers Archiv - European Journal of Physiology, 2017, 469 : 1267 - 1275
  • [2] DETERMINATION OF O2 AND CO2 CONTENT IN MICROLITER BLOOD-SAMPLES
    ZANDER, R
    LANG, W
    WOLF, HU
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1976, 365 : R17 - R17
  • [3] TOTAL BLOOD CO2 AND CO ESTIMATION BY INFRARED SPECTROMETRY
    RABINOW, BE
    WEBB, LE
    NATELSON, S
    CLINICAL CHEMISTRY, 1976, 22 (07) : 1189 - 1189
  • [4] SIMULTANEOUS ELECTROCHEMICAL DETERMINATIONS OF TOTAL CO2 AND CHLORIDES IN BIOLOGICAL-FLUIDS
    BOUSQUET, B
    GARNIER, JP
    DREUX, C
    PATHOLOGIE BIOLOGIE, 1977, 25 (05): : 353 - 358
  • [5] OSMOMETRIC METHOD FOR MEASUREMENT OF TOTAL CO2
    OH, MS
    WHANG, ESM
    CARROLL, HJ
    KIDNEY INTERNATIONAL, 1975, 8 (01) : 56 - 59
  • [6] OSMOMETRIC METHOD FOR MEASUREMENT OF TOTAL CO2
    OH, MS
    WHANG, ESM
    CARROLL, HJ
    KIDNEY INTERNATIONAL, 1974, 6 (06) : A81 - A81
  • [7] EVALUATION OF HARLECO MICRO CO2 SYSTEM FOR MEASUREMENT OF TOTAL CO2 IN SERUM OR PLASMA
    LAM, CWK
    TAN, IK
    CLINICAL CHEMISTRY, 1978, 24 (01) : 143 - 145
  • [8] Infrared optical sensor for CO2 detection
    Charpentier, Frederic
    Nazabal, Virginie
    Troles, Johann
    Coulombier, Quentin
    Brilland, Laurent
    Boussard-Pledel, Catherine
    Nemec, Petr
    Lhermite, Herve
    Charrier, Joel
    Smektala, Frederic
    Frumar, Miloslav
    Le Pierres, Karine
    Thybaud, Nathalie
    Bureau, Bruno
    OPTICAL SENSORS 2009, 2009, 7356
  • [9] ADSORBED CO2 DETECTION USING ATTENUATED TOTAL REFLECTION
    NOVOTNY, DB
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1972, 9 (06): : 1447 - &
  • [10] PARTIAL AND TOTAL REDUCTION OF CO2 EMISSIONS OF AUTOMOBILES USING CO2 TRAPS
    SEIFRITZ, W
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1993, 18 (03) : 243 - 251