Modern multivariate control chart using spatial signed rank for non-normal process

被引:11
|
作者
Haanchumpol, Thidathip [1 ]
Sudasna-na-Ayudthya, Prapaisri [1 ]
Singhtaun, Chansiri [1 ]
机构
[1] Kasetsart Univ, Fac Engn, Dept Ind Engn, Bangkok, Thailand
关键词
Spatial signed rank; Control chart; MEWMA; dMEWMA; ARL;
D O I
10.1016/j.jestch.2019.12.001
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Modern multivariate control charts that use spatial signed rank are sensitive to the detection of small shifts under non-normal or gamma distributions. In this paper, Monte Carlo simulation is used to compare the performances of multivariate control charts based on the average run length. The results show that the spatial signed-rank multivariate exponentially weighted moving average (SSRM) control chart outperforms the multivariate exponentially weighted moving average (MEWMA) control chart, the double-MEWMA control chart, and the spatial signed-rank double multivariate exponentially weighted moving average control chart when detecting small shifts in the process mean. SSRM is appropriate for data from a non-normal distribution, which is valuable for the manufacturing industry when detecting waste. Moreover, SSRM is an excellent method suitable for most industrial processes, and therefore, is a very powerful tool. (C) 2019 Karabuk University. Publishing services by Elsevier B.V.
引用
收藏
页码:859 / 869
页数:11
相关论文
共 50 条
  • [1] Remodeling Multivariate Control Chart by Using Spatial Signed Rank for Detecting Mean Shift in Normal and Non-Normal Processes
    Haanchumpol, Thidathip
    Sermpongpan, Chatchai
    THAILAND STATISTICIAN, 2023, 21 (03): : 691 - 724
  • [2] The control chart for individual observations from a multivariate non-normal distribution
    Chou, YM
    Mason, RL
    Young, JC
    COMMUNICATIONS IN STATISTICS-THEORY AND METHODS, 2001, 30 (8-9) : 1937 - 1949
  • [3] The performance of the kernel distance control chart in multivariate non-normal processes monitoring
    Chiu J.-E.
    Chiu, Jing-Er (chiuje@yuntech.edu.tw), 2018, Chinese Society for Quality (25): : 196 - 209
  • [4] Multivariate process control chart based on sign and signed-rank tests for mixture distributions
    Udom, Akaninyene Udo
    Ugwu, Offorma S.
    Ossai, Everetus O.
    Udoh, Nse S.
    JOURNAL OF STATISTICS & MANAGEMENT SYSTEMS, 2021, 24 (08): : 1669 - 1688
  • [5] EWMA Control Chart of Non-normal Totality
    Wu Wei-dong
    Wang Hai-yu
    PROCEEDINGS OF 2009 INTERNATIONAL CONFERENCE OF MANAGEMENT SCIENCE AND INFORMATION SYSTEM, VOLS 1-4, 2009, : 677 - 680
  • [6] Performance Evaluation Using Multivariate Non-Normal Process Capability
    Alatefi, Moath
    Ahmad, Shafiq
    Alkahtani, Mohammed
    PROCESSES, 2019, 7 (11)
  • [7] THE DESIGN OF ACCEPTANCE CONTROL CHART FOR NON-NORMAL DATA
    Tsai, Tzong-Ru
    Chiang, Jyun-You
    JOURNAL OF INDUSTRIAL AND PRODUCTION ENGINEERING, 2008, 25 (02) : 127 - 135
  • [8] Efficient Monitoring of a Parameter of Non-Normal Process Using a Robust Efficient Control Chart: A Comparative Study
    Chaudhary, Aamir Majeed
    Sanaullah, Aamir
    Hanif, Muhammad
    Almazah, Mohammad M. A.
    Albasheir, Nafisa A.
    Al-Duais, Fuad S.
    MATHEMATICS, 2023, 11 (19)
  • [9] Non-parametric progressive signed-rank control chart for monitoring the process location
    Abbas, Zameer
    Nazir, Hafiz Zafar
    Akhtar, Noureen
    Abid, Muhammad
    Riaz, Muhammad
    JOURNAL OF STATISTICAL COMPUTATION AND SIMULATION, 2022, 92 (12) : 2596 - 2622
  • [10] A Nonparametric Signed-Rank Control Chart for Bivariate Process Location
    Ghute, V. B.
    Shirke, D. T.
    QUALITY TECHNOLOGY AND QUANTITATIVE MANAGEMENT, 2012, 9 (04): : 317 - 328