摘要
In the context of continuous pharmaceutical oral dosage manufacturing, a control system is essential to ensure that the critical quality attributes (CQAs) are maintained within the regulatory constraints by mitigating variations generated in upstream operations. Such a system is essential to the Quality by Design (QbD) paradigm shift, which can ensure that predefined end quality attributes are achieved within an optimal economic and time bracket. In this work, an advanced model predictive control (MPC) architecture integrated with a novel real-time tablet weight measurement method has been development and implemented into a continuous direct compaction tablet manufacturing pilot-plant. The proposed control architecture has the potential to control tablet weight and tablet breaking force simultaneously by systematically decoupling and cascading the control loops. The model predictive control algorithm was experimentally found to be superior to the PID (proportional, integral and derivative) controller and thus, can be utilized for a wide range of applications to improve the quality of pharmaceutical products in continuous manufacturing. The MPC was used to control main compression force and pre compression force using main compression height and fill depth respectively as the actuators. The introduction of this methodology leads to new ways of developing MPC models, tablet weight measurement methods and control strategies that enhance the manufacturability and quality of pharmaceutical tablets.
引用
收藏
页码:159 / 178
页数:20
相关论文
共 50 条
  • [1] Implementation of an advanced hybrid MPC-PID control system using PAT tools into a direct compaction continuous pharmaceutical tablet manufacturing pilot plant
    Singh, Ravendra
    Sahay, Abhishek
    Karry, Krizia M.
    Muzzio, Fernando
    Ierapetritou, Marianthi
    Ramachandran, Rohit
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 473 (1-2) : 38 - 54
  • [2] A Validated Model for Design and Evaluation of Control Architectures for a Continuous Tablet Compaction Process
    de Barros, Fernando Nunes
    Bhaskar, Aparajith
    Singh, Ravendra
    PROCESSES, 2017, 5 (04):
  • [3] System-wide hybrid MPC-PID control of a continuous pharmaceutical tablet manufacturing process via direct compaction
    Singh, Ravendra
    Ierapetritou, Marianthi
    Ramachandran, Rohit
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2013, 85 (03) : 1164 - 1182
  • [4] Hybrid advanced control of flexible multipurpose continuous tablet manufacturing process via direct compaction
    Singh, Ravendra
    Ierapetritou, Marianthi
    Ramachandran, Rohit
    23 EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2013, 32 : 757 - 762
  • [5] Hybrid model development and nonlinear model predictive control implementation for continuous dry granulation process
    Huang, Yan-Shu
    Lagare, Rexonni B.
    Bailey, Phoebe
    Sixon, David
    Gonzalez, Marcial
    Nagy, Zoltan K.
    Reklaitis, Gintaras, V
    COMPUTERS & CHEMICAL ENGINEERING, 2024, 183
  • [6] Plant-wide Model Predictive Control for a Continuous Pharmaceutical Process
    Mesbah, Ali
    Paulson, Joel A.
    Lakerveld, Richard
    Braatz, Richard D.
    2015 AMERICAN CONTROL CONFERENCE (ACC), 2015, : 4301 - 4307
  • [7] Ensuring tablet quality via model-based control of a continuous direct compaction process
    Kirchengast, Martin
    Celikovic, Selma
    Rehrl, Jakob
    Sacher, Stephan
    Kruisz, Julia
    Khinast, Johannes
    Horn, Martin
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2019, 567
  • [8] Systematic Framework for Implementation of Material Traceability into Continuous Pharmaceutical Tablet Manufacturing Process
    Billups, Matthew
    Singh, Ravendra
    JOURNAL OF PHARMACEUTICAL INNOVATION, 2020, 15 (01) : 51 - 65
  • [9] Systematic Framework for Implementation of Material Traceability into Continuous Pharmaceutical Tablet Manufacturing Process
    Matthew Billups
    Ravendra Singh
    Journal of Pharmaceutical Innovation, 2020, 15 : 51 - 65
  • [10] A systematic framework for onsite design and implementation of a control system in a continuous tablet manufacturing process
    Singh, Ravendra
    Sahay, Abhishek
    Muzzio, Fernando
    Ierapetritou, Marianthi
    RamachandranEngineering, Rohit
    COMPUTERS & CHEMICAL ENGINEERING, 2014, 66 : 186 - 200