A high rate gaseous area detector for X-ray diffraction applications

被引:0
|
作者
Khazins, DM [1 ]
Becker, BL [1 ]
He, BB [1 ]
Diawara, Y [1 ]
Durst, RD [1 ]
Medved, SA [1 ]
Sedov, V [1 ]
Thorson, TA [1 ]
机构
[1] Bruker AXS Inc, Madison, WI 53711 USA
关键词
sealed gaseous detector; X-ray diffraction; photon counting; x-ray detector;
D O I
10.1117/12.505184
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new photon-counting area detector based on parallel-plate gas amplification with a resistive anode and remote readout electrode is described. The detector is sealed and has a sensitive area of 14x14 cm(2). The detector is unique in its ability to achieve high gain at high counting rates. A local counting rate >10(5) counts/mm(2)-sec has been achieved at a gain of up to 10(5) in a radiation-hard, non-polymerizing gas mixture. The global readout rate is limited by the delay line and electronics to <10(6) counts/sec but more sophisticated readout schemes should allow this rate to be increased by more than an order of magnitude. The operating characteristics of the detector are described and preliminary x-ray diffraction data is presented.
引用
收藏
页码:157 / 163
页数:7
相关论文
共 50 条
  • [1] Development of a novel high-rate gaseous pixel detector for time-resolved X-ray diffraction applications
    Sarvestani, A
    Besch, HJ
    Menk, RH
    Pavel, NA
    Walenta, AH
    DETECTORS FOR CRYSTALLOGRAPHY AND DIFFRACTION STUDIES AT SYNCHROTRON SOURCES, 1999, 3774 : 103 - 113
  • [2] The ''RAPID'' high rate large area X-ray detector system
    Lewis, RA
    Helsby, WI
    Jones, AO
    Hall, CJ
    Parker, B
    Sheldon, J
    Clifford, P
    Hillen, M
    Sumner, I
    Fore, NS
    Jones, RWM
    Roberts, KM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 392 (1-3): : 32 - 41
  • [3] A LARGE-AREA DETECTOR FOR X-RAY APPLICATIONS
    RODRICKS, B
    HUANG, Q
    HOPF, R
    WANG, KM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 572 - 576
  • [4] A CCD area detector for X-ray diffraction under high pressure for rotating anode source
    Amar Sinha
    Alka B. Garg
    V. Vijayakumar
    B. K. Godwal
    S. K. Sikka
    Bulletin of Materials Science, 2000, 23 : 151 - 154
  • [5] X-ray detector for diffraction studies
    Mandelis, Andreas
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (09):
  • [6] A CCD area detector for X-ray diffraction under high pressure for rotating anode source
    Sinha, A
    Garg, AB
    Vijayakumar, V
    Godwal, BK
    Sikka, SK
    BULLETIN OF MATERIALS SCIENCE, 2000, 23 (02) : 151 - 154
  • [7] High throughput high resolution Vortex™ detector for X-ray diffraction
    Iwanczyk, JS
    Patt, BE
    Barkan, S
    Feng, L
    Tull, CR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (06) : 2470 - 2473
  • [8] Study of a new X-ray gaseous detector
    Ismaili, Y
    Fontbonne, JM
    Mosrin, P
    Tamain, B
    Tillier, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 423 (01): : 68 - 74
  • [9] A pixelated X-ray detector for diffraction imaging at next generation, high rate FEL sources
    Lodola, L.
    Ratti, L.
    Comotti, D.
    Fabris, L.
    Grassi, M.
    Malcovati, P.
    Manghisoni, M.
    Re, V.
    Traversi, G.
    Vacchi, C.
    Batignani, G.
    Bettarini, S.
    Casarosa, G.
    Forti, F.
    Morsani, F.
    Paladino, A.
    Paoloni, E.
    Rizzo, G.
    Benkechkache, M. A.
    Dalla Betta, G. -F.
    Mendicino, R.
    Pancheri, L.
    Verzellesi, G.
    Xu, H.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIX, 2017, 10392
  • [10] X-Ray Diffraction by Gaseous Benzene Derivatives
    Pierce, W. C.
    JOURNAL OF CHEMICAL PHYSICS, 1934, 2 (01):