Accuracy of real-time 3D echocardiography in the evaluation of functional anatomy of mitral regurgitation

被引:42
|
作者
Agricola, Eustachio [1 ]
Oppizzi, Michele
Pisani, Matteo
Maisano, Francesco [2 ]
Margonato, Alberto
机构
[1] Hosp San Raffaele, IRCCS, Div Noninvas Cardiol, Cardiothorac Dept, I-20132 Milan, Italy
[2] Hosp San Raffaele, IRCCS, Div Cardiac Surg, I-20132 Milan, Italy
关键词
real-time 3D echocardiography; mitral regurgitation; mitral prolapse; flail;
D O I
10.1016/j.ijcard.2007.05.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the feasibility of mitral valve (MV) reconstruction protocol by real-time 3D echocardiography (RT3DE) in the assessment mitral regurgitant (MR) lesions, and to determine the accuracy of RT3DE compared with transthoracic (TTE) and transesophageal (TEE) echocardiographies using surgical findings as gold standard. Patients and methods: Sixty-three consecutive patients (mean age 61.7 +/- 12.5 years, 35 men and 28 women) with severe organic MR were enrolled. Data were acquired in zoom and in full-volume modes from apical and/or parasternal windows. A volume rendered en-face view of MV and five serial longitudinal cut planes were reconstructed to visualize all segments of both leaflets. Results: The feasibility of RT3D reconstruction was 94%. Compared with surgical diagnosis, the accuracy of RT3D was 91% for aetiology, 92% for mechanisms, 94% for prolapse, 88% for flail and 94% for defect location. Diagnostic accuracy was significant higher for RT3D than TTE for all end points except for flail lesion and similar to TEE but inferior to this for flail lesion. The accuracy, sensitivity and specificity were higher in patients with good-excellent than those with poor image quality regarding aetiology, mechanisms and defect location (all p=0.0001). Conclusions: RT3D imaging of MV is feasible and accurate in defining aetiology, mechanism and defect location in patients with MR and has incremental diagnostic value if TTE is inconclusive and similar diagnostic value of TEE except for flail lesion. RT3D, at least in patients with good acoustic window, may obviate the need for subsequent TEE and/or can be considered a complementary technique to study MV in patients with MR. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:342 / 349
页数:8
相关论文
共 50 条
  • [1] Geometry of mitral apparatus in functional mitral regurgitation: Real-time 3D echocardiography study
    Kwan, J
    Park, SM
    Jeon, MJ
    Lee, CK
    Kim, DH
    Park, KS
    Lee, WH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 281A - 281A
  • [2] Accuracy of real-time 3D echocardiography in assessing the anatomy of the mitral valve in patients undergoing surgery for severe degenerative mitral regurgitation
    Badano, L. P.
    Pezzutto, N.
    Pavoni, D.
    Cinello, M.
    Marinigh, R.
    Gianfagna, P.
    Fioretti, P. M.
    EUROPEAN HEART JOURNAL, 2007, 28 : 153 - 154
  • [3] Qualitative and quantitative assessment of mitral regurgitation by real-time 3D echocardiography
    Kapetanakis, S
    Corrigan, N
    DeGuzman, J
    Owen, S
    Murray, O
    Monaghan, MJ
    HEART, 2004, 90 : 31 - 31
  • [4] Real-time 3D echocardiography: impact on quantification of mitral regurgitation by PISA method
    Necas, J.
    Kovalova, S.
    Vespalec, J.
    EUROPEAN HEART JOURNAL, 2007, 28 : 395 - 395
  • [5] Real-Time 3D Transesophageal Echocardiography for the Evaluation of Rheumatic Mitral Stenosis
    Schlosshan, Dominik
    Aggarwal, Gunjan
    Mathur, Gita
    Allan, Roger
    Cranney, Greg
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (06) : 580 - 588
  • [6] Real-time 3D echocardiography and the role of interpapillary muscle dyssynchrony in functional mitral regurgitation in severe heart failure
    Ho, Emily
    Kapetanakis, Stamatis
    Pearson, Peter
    Bhan, Amit
    Rana, Bushra
    Murgatroyd, Francis
    Monaghan, Mark J.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 130A - 130A
  • [7] Quantification of Functional Mitral Regurgitation by Real-Time 3D Echocardiography Comparison With 3D Velocity-Encoded Cardiac Magnetic Resonance
    Marsan, Nina Ajmone
    Westenberg, Jos J. M.
    Ypenburg, Claudia
    Delgado, Victoria
    van Bommel, Rutger J.
    Roes, Stijntje D.
    Nucifora, Gaetano
    van der Geest, Rob J.
    de Roos, Albert
    Reiber, Johan C.
    Schalij, Martin J.
    Bax, Jeroen J.
    JACC-CARDIOVASCULAR IMAGING, 2009, 2 (11) : 1245 - 1252
  • [8] Direct planimetry of mitral valve regurgitation orifice area by real-time 3D transesophageal echocardiography
    Altiok, E.
    Hamada, S.
    Van Hall, S.
    Hanenberg, M.
    Grabskaya, E.
    Becker, M.
    Marx, N.
    Hoffmann, R.
    EUROPEAN HEART JOURNAL, 2010, 31 : 4 - 4
  • [9] Quantitative digital color Doppler and real-time 3D echocardiography for evaluating aortic and mitral regurgitation
    Tsujino, Hiroyuki, 2000, Elsevier Science Ltd, Exeter, United Kingdom (26):
  • [10] Accuracy of real-time 3D echocardiography to describe the pathologic scallops of patients with mitral prolapse
    Chico, JLG
    Zamorano, JL
    de Isla, LP
    Orejas, M
    Aguilera, L
    Almería, C
    López, JLR
    Macaya, C
    EUROPEAN HEART JOURNAL, 2004, 25 : 650 - 650