EMF Analysis for a 380kV Transmission OHL in the Vicinity of Buried Pipelines

被引:8
|
作者
Shwehdi, Mohamed H. [1 ]
Alaqil, Mohammed A. [1 ]
Mohamed, S. Raja [1 ]
机构
[1] King Faisal Univ, Coll Engn, Elect Engn Dept, Al Hasa 31982, Saudi Arabia
关键词
Electromagnetic field; EM interference; gradient control wires; induced voltage; mitigation system; transmission lines; water pipelines; LINES;
D O I
10.1109/ACCESS.2019.2961109
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The induction of Electromagnetic Fields that are generated through the interaction of high-voltage transmission lines with neighboring buried metallic pipelines produce uncontrolled hazardous potential voltages, which can infringe safety limits. The paper presents the findings of the electromagnetic interference effects on water buried pipelines constructed within the vicinity of an Extra High-Voltage 380 kV transmission overhead line (OHL) in Riyadh-Salboukh route within the Saudi national grid power network. The presented case study showed that some segments of the buried pipelines under this line have not experienced voltages that exceeded the standard limits for the steady-state condition. However, in the event of L-G fault currents (short circuits), the pipelines experienced a voltage level that is above the local electric utility safety limits. Therefore, the work produced implemented the mitigation method of gradient control wires to reduce the potential voltages experienced by the pipelines to enforce the safety limit. The variation of wire resistance has been proven to be a feasible solution to reduce the excessive induced voltages. The comparison has shown that a 0.1 Omega is sufficient to maintain the safe limit for at least this line. These findings may vary depending on the OHL design and site topology.
引用
收藏
页码:3710 / 3717
页数:8
相关论文
共 7 条
  • [1] Comparison of wind energy integration into a 110kV and a 380kV transmission system - Impact on power quality of MV and LV networks
    Vilchez, E.
    Stenzel, J.
    2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 755 - 760
  • [2] Study on Electromagnetic Influence of 750kV AC Transmission Lines on Multiple Buried Pipelines
    Sun Haifeng
    Wang Pei
    Chang Haojing
    Ai Xiancang
    E Tianlong
    Su Bonian
    Zhu Rongrong
    Li Zhihong
    Wang Chunfeng
    2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 31 - 34
  • [3] Switching Analysis in Hybrid OHL-Submarine Cable 500-kV Transmission System
    Nababan, Binhot P.
    Banjar-Nahor, Kevin Marojahan
    Marbun, Musa Partahi
    Suwarno, Nanang
    Hariyanto, Nanang
    IEEE OPEN ACCESS JOURNAL OF POWER AND ENERGY, 2024, 11 : 293 - 302
  • [4] Effect of Increasing Energy Demand on the Corrosion Rate of Buried Pipelines in the Vicinity of High Voltage Overhead Transmission Lines
    Adedeji, K. B.
    Ponnle, A. A.
    Abe, B. T.
    Jimoh, A. A.
    2015 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES & POWER ELECTRONICS (ACEMP), 2015 INTL CONFERENCE ON OPTIMIZATION OF ELECTRICAL & ELECTRONIC EQUIPMENT (OPTIM) & 2015 INTL SYMPOSIUM ON ADVANCED ELECTROMECHANICAL MOTION SYSTEMS (ELECTROMOTION), 2015, : 299 - 303
  • [5] Transient Analysis of 380-kV Transmission System of Central Anatolia of Turkey
    Aydin, Musa
    Unver, M. Ugur
    2012 16TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE (MELECON), 2012, : 776 - 779
  • [6] Analysis of Electromagnetic Influence between High-voltage AC Transmission Lines and Buried Oil and Gas Pipelines(May 2018)
    Qin Tao
    Bai Suna
    Shao Bingran
    Yang Tao
    Ma Yunfei
    Yang Xinliang
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 1099 - 1104
  • [7] Comparison the 154 and 380 kv transmission system network of Northwest Anatolia by making power flow emulation with constraint analysis in Turkey
    Pamuk, Nihat
    Uyaroglu, Yilmaz
    SCIENTIFIC RESEARCH AND ESSAYS, 2011, 6 (02): : 469 - 478