Diaphragm EMG measured by cervical magnetic and electrical phrenic nerve stimulation

被引:47
|
作者
Luo, YM
Polkey, MI
Johnson, LC
Lyall, RA
Harris, ML
Green, M
Moxham, J
机构
[1] Univ London Kings Coll, Sch Med & Dent, Resp Muscle Lab, London SE5 9PJ, England
[2] Royal Brompton Hosp, London SE5 9PJ, England
关键词
esophageal electrode; cervical magnetic stimulation; phrenic nerve conduction time;
D O I
10.1152/jappl.1998.85.6.2089
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The purpose of the study was to compare electrical stimulation (ES) and cervical magnetic stimulation (CMS) of the phrenic nerves for the measurement of the diaphragm compound muscle action potential (CMAP) and phrenic nerve conduction time. A specially designed esophageal catheter with three pairs of electrodes was used, with control of electrode positioning in 10 normal subjects. Pair A and pair B were close to the diaphragm (pair A lower than pair B); pair C was positioned 10 cm above the diaphragm to detect the electromyogram from extradiaphragmatic muscles. Electromyograms were also recorded from upper and lower chest wall surface electrodes. The shape of the CMAP measured with CMS (CMS-CMAP) usually differed from that of the CMAP measured with ES (ES-CMAP). Moreover, the latency of the CMS-CMAP from pair B (5.3 +/- 0.4 ms) was significantly shorter than that from pair A (7.1 +/- 0.7 ms). The amplitude of the CMS-CMAP (1.00 +/- 0.15 mV) was much higher than that of ES-CMAP (0.26 +/- 0.15 mV) when recorded from pair C. Good-quality CMS-CMAPs could be recorded in some subjects from an electrode positioned very low in the esophagus. The differences between ES-CMAP and CMS-CMAP recorded either from esophageal or chest wall electrodes make CMS unreliable for the measurement of phrenic nerve conduction time.
引用
收藏
页码:2089 / 2099
页数:11
相关论文
共 50 条
  • [1] Effect of lung volume on the oesophageal diaphragm EMG assessed by magnetic phrenic nerve stimulation
    Luo, YM
    Lyall, RA
    Harris, ML
    Hawkins, P
    Hart, N
    Polkey, MI
    Moxham, J
    EUROPEAN RESPIRATORY JOURNAL, 2000, 15 (06) : 1033 - 1038
  • [2] Surface electrode positioning and the reproducibility of diaphragm EMG using magnetic stimulation of the phrenic nerve
    Glerant, JCH
    Mustfa, N
    Man, WD
    Luo, YM
    Rafferty, G
    Polkey, MI
    Moxham, J
    THORAX, 2001, 56 : 50 - 50
  • [3] Diaphragm pacing by electrical stimulation of the phrenic nerve: 1996 update
    WeeseMayer, DE
    PEDIATRIC PULMONOLOGY, 1997, 23 (02) : 157 - 159
  • [4] DIAPHRAGM PACING BY ELECTRICAL-STIMULATION OF THE PHRENIC-NERVE
    GLENN, WWL
    PHELPS, ML
    NEUROSURGERY, 1985, 17 (06) : 974 - 984
  • [5] ELECTRICAL ACTIVITY IN HUMAN DIAPHRAGM DURING PHRENIC NERVE STIMULATION
    DELHEZ, L
    ARCHIVES INTERNATIONALES DE PHYSIOLOGIE ET DE BIOCHIMIE, 1969, 77 (01): : 140 - &
  • [6] Effect of lung volume on the diaphragm EMG amplitude elicited by phrenic nerve stimulation
    Luo, YM
    Lyall, RA
    Harris, ML
    Polkey, MI
    Green, M
    Moxham, J
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A582 - A582
  • [7] Cervical magnetic stimulation of the phrenic nerves in bilateral diaphragm paralysis
    Mills, GH
    Kyroussis, D
    Hamnegard, CH
    Wragg, S
    Polkey, MI
    Moxham, J
    Green, M
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 155 (05) : 1565 - 1569
  • [8] Quantification of the esophageal diaphragm electromyogram with magnetic phrenic nerve stimulation
    Luo, YM
    Lyall, RA
    Harris, ML
    Rafferty, GF
    Polkey, MI
    Moxham, J
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (05) : 1629 - 1634
  • [9] Diaphragm Pacing by Phrenic Nerve Stimulation
    Perez, Iris A.
    Kun, Sheila
    Keens, Thomas G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193 (08)
  • [10] ELECTRICAL-ACTIVITY OF DIAPHRAGM AFTER PHRENIC-NERVE STIMULATION
    DELHEZ, L
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1975, 39 (03): : 303 - 303