Reliability of Simultaneous Visual Field Testing

被引:4
|
作者
Kramer, Benjamin C. [1 ]
Musch, David C. [1 ,2 ]
Niziol, Leslie M. [1 ]
Weizer, Jennifer S. [1 ]
机构
[1] Univ Michigan, Sch Med, Dept Ophthalmol & Visual Sci, Ann Arbor, MI USA
[2] Univ Michigan, Sch Publ Hlth, Dept Epidemiol, Ann Arbor, MI 48109 USA
关键词
AUTOMATED PERIMETRY; GLAUCOMA; PERFORMANCE; EXPERIENCE; INDEXES;
D O I
10.1016/j.ophtha.2011.08.021
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To test for differences in reliability and performance between traditional, isolated perimetry and simultaneous testing with 2 patients in the same room. Design: Comparative case series. Participants: A total of 471 eyes of 261 subjects. Methods: Consecutive patients undergoing Humphrey visual field (VF) testing in the Kellogg Eye Center glaucoma clinic were screened. Patients who underwent VF testing with another patient in the same room ("double field") during the screening interval were included as subjects if a comparison isolated VF from the same patient ("single field") was obtainable from the clinic's records. An individual subject's performance and reliability on his/her double and single fields were compared using a paired t test. In addition, the double fields were stratified by technician-to-patient ratio, and their VF indices were compared using an independent 2-sample t test. Main Outcome Measures: False negatives, false positives, fixation losses, mean deviation, pattern standard deviation, VF index, VF duration, and technician-to-patient ratio. Results: No significant differences between single and double fields were found in the reliability or performance parameters. Test duration was longer in double fields than in single fields (6.1 vs. 5.9 minutes, P<0.001). There were no significant differences found in reliability or performance indices when the double-field data were stratified by technician-to-patient ratio (1: 2 vs. 2: 2). Conclusions: There is no decrement in VF performance or reliability when patients undergo simultaneous testing with another patient in the same room. Busy clinical practices may be able to minimize costs and maximize efficiency by having 1 technician simultaneously supervise more than 1 test-taker in the same space. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2012; 119: 304-307 (C) 2012 by the American Academy of Ophthalmology.
引用
收藏
页码:304 / 307
页数:4
相关论文
共 50 条
  • [1] Reliability and artifact in automated visual field testing of children
    Kerr, NC
    Litchford, DW
    Dong, QM
    Netland, PA
    ANNALS OF OPHTHALMOLOGY, 2005, 37 (03) : 185 - 189
  • [2] Remote Video Monitoring of Simultaneous Visual Field Testing
    Meshkin, Ryan S.
    Zhao, Yan
    Elze, Tobias
    Boland, Michael V.
    Friedman, David S.
    JOURNAL OF GLAUCOMA, 2022, 31 (07) : 488 - 493
  • [3] Assessing the Reliability of Humphrey Visual Field Testing in an Urban Population
    Peracha, Manal
    Hughes, Bret
    Tannir, Justin
    Momi, Rominder
    Goyal, Anju
    Juzych, Mark
    Kim, Chaesik
    McQueen, Melanie
    Eby, Alicia
    Fatima, Farvah
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [4] RELIABILITY OF VISUAL-FIELD RESULTS OVER REPEATED TESTING
    KATZ, J
    SOMMER, A
    WITT, K
    OPHTHALMOLOGY, 1991, 98 (01) : 70 - 75
  • [5] Sequential versus simultaneous visual field testing: comparison of two perimeters
    Chisholm, Catharine
    Ho, Derek
    El-Nimri, Nevin W.
    Arias, Juan D.
    Durbin, Mary
    Chisholm, Catharine
    Ho, Derek
    El-Nimri, Nevin W.
    Arias, Juan D.
    Durbin, Mary
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [6] Reliability of standardized visual field testing in patients under 18 years of age
    Mitchell, EW
    Fischer, N
    Brooks, SE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 1841 - 1841
  • [7] Factors Associated With Visual Field Testing Reliability in Children With Glaucoma or Suspected Glaucoma
    Kumar, Anika
    Hekmatjah, Natan
    Yu, Yinxi
    Han, Ying
    Ying, Gui-Shuang
    Oatts, Julius T.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 264 : 187 - 193
  • [8] On Simultaneous Masking in the Visual Field
    Giovanni Bruno Vicario
    Axiomathes, 2003, 13 (3-4): : 399 - 432
  • [9] Determinants of Visual Field Reliability
    Ramulu, Pradeep
    Boland, Michael
    Wang, Jiangxia
    Xu, Li
    Brown, Jamie
    Friedman, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [10] Humphrey visual field reliability in glaucoma the effect of past performance and frequency of testing.
    Viswanathan, AC
    Fitzke, FW
    Hitchings, RA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S294 - S294