Design of cold-formed stainless steel tubular joints at elevated temperatures

被引:41
|
作者
Feng, Ran [1 ]
Young, Ben [1 ]
机构
[1] Univ Hong Kong, Dept Civil Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Cold-formed stainless steel; Elevated temperature; Finite element; High strength; Rectangular hollow section; Square hollow section; Tubular joint; STRESS-STRAIN CURVES; ROTATIONAL CAPACITY; T-JOINTS; X-JOINT; K-JOINT; I-BEAMS; COLUMNS; FIRE; TUBES/; TESTS;
D O I
10.1016/j.engstruct.2011.10.029
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper describes the numerical investigation of cold-formed stainless steel tubular T-joints, X-joints and X-joints with chord preload at elevated temperatures. A series of finite element analysis was performed on stainless steel tubular joints. The tubular T- and X-joints were welded from cold-formed square and rectangular hollow sections as brace and chord members. The material properties of high strength stainless steel (duplex and high strength austenitic) and normal strength stainless steel (AISI 304) at elevated temperatures were carefully incorporated in the finite element models. An extensive numerical study of 450 specimens consists of 20 T-joints, 10 X-joints and 20 X-joints with chord preload at different temperatures ranged from 22 to 870 degrees C was conducted. The joint strengths, failure modes and load-deformation curves of stainless steel tubular joints at elevated temperatures were obtained from the finite element analysis. The numerical results were compared with the design strengths calculated from the existing design rules for stainless steel tubular joints at normal room temperature (ambient temperature) by using the material properties of stainless steel tubes at elevated temperatures. In the calculation of the joint strengths, the reduced material property of 0.2% proof stress was used due to the deterioration of material at elevated temperatures. Furthermore, design equations for cold-formed stainless steel tubular T- and X-joints at elevated temperatures are proposed by introducing a temperature factor (xi(T)). A reliability analysis was performed to assess the existing and proposed design equations. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:188 / 202
页数:15
相关论文
共 50 条
  • [1] Structural design of cold-formed stainless steel tubular X- and T-joints at elevated temperatures
    Lan, Xiaoyi
    Huang, Yuner
    THIN-WALLED STRUCTURES, 2016, 108 : 270 - 279
  • [2] Performance of cold-formed stainless steel tubular columns at elevated temperatures
    To, Ernest Chiu-Yin
    Young, Ben
    ENGINEERING STRUCTURES, 2008, 30 (07) : 2012 - 2021
  • [3] FINITE ELEMENT ANALYSIS OF COLD-FORMED STAINLESS STEEL TUBULAR T-JOINTS AT ELEVATED TEMPERATURES
    Feng, R.
    Young, B.
    Proceedings of the 7th International Conference on Steel and Aluminium Structures (ICSAS 2011), 2011, : 391 - 397
  • [4] Web crippling tests of cold-formed stainless steel tubular sections at elevated temperatures
    Zhan, Ke-Jiang
    Li, Hai -Ting
    Fan, Zhi-Hao
    Young, Ben
    ENGINEERING STRUCTURES, 2024, 304
  • [5] Theoretical analysis of cold-formed stainless steel tubular joints
    Feng, Ran
    Young, Ben
    ENGINEERING STRUCTURES, 2015, 83 : 99 - 115
  • [6] Behaviour of cold-formed stainless steel beams at elevated temperatures
    Ju Chen
    Wei-liang Jin
    Journal of Zhejiang University-SCIENCE A, 2008, 9 : 1507 - 1513
  • [8] Behaviour of cold-formed stainless steel beams at elevated temperatures
    Chen, Ju
    Jin, Wei-liang
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2008, 9 (11): : 1507 - 1513
  • [9] Design of cold-formed stainless steel tubular T- and X-joints
    Feng, Ran
    Young, Ben
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (03) : 421 - 436
  • [10] Web crippling behaviour of cold-formed duplex stainless steel tubular sections at elevated temperatures
    Zhou, Feng
    Young, Ben
    ENGINEERING STRUCTURES, 2013, 57 : 51 - 62