PHOTO-INDUCED FLOW-INJECTION DETERMINATION OF NITRATE IN WATER

被引:0
|
作者
Mikuska, Pavel [1 ]
Capka, Lukas [1 ]
Vecera, Zbynek [1 ]
Kalinichenko, Ivan [2 ]
Kellner, Josef [3 ]
机构
[1] Acad Sci Czech Republ, Inst Analyt Chem, Brno, Czech Republic
[2] Natl Acad Sci Ukraine, AV Dumansky Inst Colloid & Water Chem, Kiev, Ukraine
[3] Univ Def, Brno, Czech Republic
关键词
NITRITE;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive flow-injection method for the chemiluminescent determination of ultra-low concentration of nitrate in water is presented. Nitrate is on-line photolytically converted to peroxynitrite by absorption of UV light inside of 60 mm long quartz capillary (i.d. 530 mu m, o.d. 720 mu m). Peroxynitrite is subsequently determined by the chemiluminescent reaction with luminol. The detection limit of nitrate is 7 x 10(-10) M (S/N = 3). Linear range of the method is 2 x 10(-9) to 1 x 10(-5) M nitrate. The interference of nitrite is eliminated by its conversion to nitrogen after mixing of sample with a solution of sulfamidic acid. Other common anions do not interfere. The interference of cations is eliminated by passing the sample through a cation-exchange column. FIA procedure allows analysing of 15 samples per hour. The method was applied to the determination of nitrate in various real water samples. The results are in good agreement with a reference ion chromatographic method.
引用
收藏
页码:151 / 154
页数:4
相关论文
共 50 条
  • [1] Photo-induced flow-injection determination of nitrate in water
    Mikuska, Pavel
    Capka, Lukas
    Vecera, Zbynek
    Kalinichenko, Ivan
    Kellner, Josef
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (10) : 1038 - 1049
  • [2] Simultaneous determination of nitrite and nitrate in water by chemiluminescent flow-injection analysis
    Mikuska, P
    Vecera, Z
    ANALYTICA CHIMICA ACTA, 2003, 495 (1-2) : 225 - 232
  • [3] SIMULTANEOUS DETERMINATION OF NITRITE AND NITRATE IN WATER USING FLOW-INJECTION BIAMPEROMETRY
    TROJANOWICZ, M
    MATUSZEWSKI, W
    SZOSTEK, B
    MICHALOWSKI, J
    ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) : 391 - 398
  • [4] DEVELOPMENT OF A FLOW INJECTION MANIFOLD FOR NAPROPAMIDE DETERMINATION BY PHOTO-INDUCED CHEMILUMINESCENCE
    Catala-Icardo, Monica
    Luis Lopez-Paz, Jose
    Asensio-Martin, Victor
    ANALYTICAL LETTERS, 2012, 45 (08) : 872 - 882
  • [5] Simultaneous spectrophotometric determination of nitrite and nitrate in water samples by flow-injection analysis
    Chen, H
    Fang, YJ
    An, TC
    Zhu, K
    Lu, JR
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 76 (02) : 89 - 98
  • [6] Simple flow-injection system for the simultaneous determination of nitrite and nitrate in water samples
    Burakham, R
    Oshima, M
    Grudpan, K
    Motomizu, S
    TALANTA, 2004, 64 (05) : 1259 - 1265
  • [7] SIMULTANEOUS DETERMINATION OF NITRATE AND NITRITE BY FLOW-INJECTION ANALYSIS
    GINE, MF
    BERGAMIN, H
    ZAGATTO, EAG
    REIS, BF
    ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 191 - 197
  • [8] DETERMINATION OF NITRATE AND NITRITE IN SEAWATER BY FLOW-INJECTION ANALYSIS
    JOHNSON, KS
    PETTY, RL
    LIMNOLOGY AND OCEANOGRAPHY, 1983, 28 (06) : 1260 - 1266
  • [9] SIMULTANEOUS FLOW-INJECTION DETERMINATION OF NITRATE AND NITRITE IN WATER BY GAS-PHASE CHEMILUMINESCENCE
    AOKI, T
    WAKABAYASHI, M
    ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 308 - 312
  • [10] Flow-injection analysis spectrophotometric determination of nitrite and nitrate in water samples by reaction with proflavin
    Guerrero, RS
    Benito, CG
    Calatayud, JM
    TALANTA, 1996, 43 (02) : 239 - 246