Investigation of False Positive Results with an Oral Fluid Rapid HIV-1/2 Antibody Test

被引:36
|
作者
Jafa, Krishna [1 ,4 ]
Patel, Pragna [1 ]
MacKellar, Duncan A. [1 ]
Sullivan, Patrick S. [1 ]
Delaney, Kevin P. [1 ]
Sides, Tracy L. [2 ]
Newman, Alexandra P. [3 ,4 ]
Paul, Sindy M. [5 ]
Cadoff, Evan M. [6 ]
Martin, Eugene G. [6 ]
Keenan, Patrick A. [7 ]
Branson, Bernard M. [1 ]
机构
[1] Ctr Dis Control & Prevent, Natl Ctr HIV STD & TB Prevent, Div HIV AIDS Prevent, Atlanta, GA 30333 USA
[2] Minnesota Dept Hlth, Infect Dis Epidemiol Prevent & Control Div, St Paul, MN USA
[3] Wisconsin Div Publ Hlth, Madison, WI USA
[4] Ctr Dis Control & Prevent, Off Workforce & Career Dev, Epidemiol Program Off, Atlanta, GA USA
[5] New Jersey Dept Hlth & Senior Serv, Div HIV AIDS Serv, Trenton, NJ USA
[6] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Dept Pathol & Lab Med, New Brunswick, NJ USA
[7] Univ Minnesota, Sch Med, Dept Family Med & Community Hlth, Minneapolis, MN 55455 USA
来源
PLOS ONE | 2007年 / 2卷 / 01期
关键词
D O I
10.1371/journal.pone.0000185
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background. In March 2004, the OraQuickH rapid HIV antibody test became the first rapid HIV test approved by the US Food and Drug Administration for use on oral fluid specimens. Test results are available in 20 minutes, and the oral fluid test is non-invasive. From August 2004-June 2005, we investigated a sudden increase in false-positive results occurring in a performance study of OraQuickH oral-fluid rapid HIV tests in Minnesota. Methodology/Principal Findings. In a field investigation, we reviewed performance study data on oral-fluid and whole-blood OraQuickH rapid HIV test device lots and expiration dates and assessed test performance and interpretation with oral-fluid and whole-blood specimens by operators who reported false-positive results. We used multivariate logistic regression to evaluate client demographic and risk characteristics associated with false-positive results. Next, we conducted an incidence study of false-positive OraQuick rapid HIV tests in nine US cities and tested both oral-fluid and finger-stick whole-blood specimens from clients; reactive tests were confirmed with Western blot. Sixteen (4.1%) false-positive oral-fluid results occurred in the performance study from April 15, 2004 through August 31, 2004 with unexpired devices from six test lots among 388 HIV-uninfected clients (specificity, 95.9%; 95% CI: 93.4-97.6). Three test operators who had reported false-positive results performed and interpreted the test according to package-insert instructions. In multivariate analysis, only older age was significantly associated with false-positive results (adjusted odds ratio = 4.5, 95% CI: 1.2-25.7). In the incidence study, all valid oral-fluid and whole-blood results from 2,268 clients were concordant and no false-positive results occurred (100% specificity). Conclusions/Significance. The field investigation did not identify a cause for the increase in false-positive oral-fluid results, and the incidence study detected no false-positive results. The findings suggest this was an isolated cluster; the test's overall performance was as specified by the manufacturer.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Acute Dengue Fever Causes False-Positive Reactivity in OraQuick Rapid HIV-1/2 Antibody Test
    Mao, Alice
    Obi-Gwacham, Chidera
    Hill, Tamsey
    Ryan, Catherine
    Hendricks, Arthur
    McKellar, Mehri
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2010, 55 (05) : 641 - 641
  • [2] OraQuick® ADVANCE rapid HIV-1/2 antibody test
    Reynolds, SJ
    Muwonga, J
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2004, 4 (05) : 587 - 591
  • [3] Calypte® AWARE™ HIV-1/2 OMT antibody test using oral fluid:: special challenges of rapid HIV testing in the developing world
    Gottfried, TD
    Mink, RW
    Phanuphak, P
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2006, 6 (02) : 139 - 144
  • [4] Performance of OraQuick Advance® Rapid HIV-1/2 Antibody Test for detection of antibodies in oral fluid and serum/plasma in HIV-1 + subjects carrying different HIV-1 subtypes and recombinant variants
    Holguin, Africa
    Gutierrez, Maite
    Portocarrero, Nieves
    Rivas, Pablo
    Baquero, Margarita
    JOURNAL OF CLINICAL VIROLOGY, 2009, 45 (02) : 150 - 152
  • [5] Causes of false-positive HIV rapid diagnostic test results
    Klarkowski, Derryck
    O'Brien, Daniel P.
    Shanks, Leslie
    Singh, Kasha P.
    EXPERT REVIEW OF ANTI-INFECTIVE THERAPY, 2014, 12 (01) : 49 - 62
  • [6] FDA approves rapid HIV-1 antibody test
    不详
    CLINICAL INFECTIOUS DISEASES, 2003, 36 (01) : I - II
  • [7] Performance of an oral fluid rapid HIV-1/2 test: experience from four CDC studies
    Delaney, Kevin P.
    Branson, Bernard M.
    Uniyal, Apurva
    Kerndt, Peter R.
    Keenan, Patrick A.
    Jafa, Krishna
    Gardner, Ann D.
    Jamieson, Denise J.
    Bulterys, Marc
    AIDS, 2006, 20 (12) : 1655 - 1660
  • [8] Potential for false positive HIV test results with the serial rapid HIV testing algorithm
    Steven Baveewo
    Moses R Kamya
    Harriet Mayanja-Kizza
    Robin Fatch
    David R Bangsberg
    Thomas Coates
    Judith A Hahn
    Rhoda K Wanyenze
    BMC Research Notes, 5 (1)
  • [9] ANALYSIS OF FALSE-POSITIVE RESULTS IN ELISA TEST FOR HIV-1 IN BLOOD DONORS WITH POSITIVE SEROLOGY OR INCONCLUSIVE
    Vitor Anjos, E. Borges
    Bezerra, A.
    Valenca, M.
    Andrade, P.
    Costa, S.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2010, 95 : 729 - 729
  • [10] Low rate of false-positive results with use of a rapid HIV test
    Salgado, CD
    Flanagan, HL
    Haverstick, DM
    Farr, BM
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2002, 23 (06): : 335 - 337