Selective determination of acenaphthylene by flow injection analysis with tris(2,2′-bipyridine)ruthenium(II) chemiluminescence detection

被引:3
|
作者
Li, Ming [2 ]
Lee, Sang Hak [1 ]
机构
[1] Kyungpook Natl Univ, Dept Chem, Taegu 702701, South Korea
[2] Pohang Univ Sci & Technol, Dept Chem, Div Mol & Life Sci, Pohang 790784, South Korea
关键词
acenaphthylene; ruthenium; chemiluminescence; flow injection; soil;
D O I
10.1016/j.talanta.2007.06.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, rapid flow injection chemiluminescence (FI-CL) method has been developed for selective determination of acenaphthylene (ACY), based on the CL produced in the reaction of tris(2,2'-bipyridine)ruthenium(III) (Ru(biPY)(3)(3+)) and ACY in an acidic buffer solution. Under the optimum experimental conditions, the calibration curve was linear over the range 5.0 x 10(-3) to 4.0 x 10(-7) mol L-1 for ACY. The detection limit (SIN= 3) was 2.0 x 10(-7) mol L-1 and the relative standard deviation of 10 replicate measurements was 2.3% for 5.0 x 10(-5) mol L-1 of ACY. Selectivity of CL reaction of ACY from other 15 polycyclic aromatic hydrocarbons (PAHs) was investigated by flow injection method. The method was applied to determine the ACY content in soil. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:265 / 270
页数:6
相关论文
共 50 条
  • [1] Pulse injection analysis with chemiluminescence detection:: determination of citric acid using tris-(2,2′-bipyridine) ruthenium(II)
    He, Z
    Gao, H
    Yuan, LJ
    Lu, SF
    Meng, H
    Li, XY
    Zeng, Y
    TALANTA, 1998, 47 (02) : 301 - 304
  • [2] Determination of proline in wine using flow injection analysis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection
    Costin, JW
    Barnett, NW
    Lewis, SW
    TALANTA, 2004, 64 (04) : 894 - 898
  • [3] Selective Detection of Hydroxyl Radical Scavenging Capacity Based on Electrogenerated Chemiluminescence Detection Using Tris(2,2′-bipyridine)ruthenium(III) by Flow Injection Analysis
    Nobushi, Yasuhito
    Uchikura, Kazuo
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (01) : 117 - 120
  • [4] Stable Tris(2,2′-bipyridine)ruthenium(III) for Chemiluminescence Detection
    McDermott, Geoffrey P.
    Jones, Philip
    Barnett, Neil W.
    Donaldson, David N.
    Francis, Paul S.
    ANALYTICAL CHEMISTRY, 2011, 83 (13) : 5453 - 5457
  • [5] Determination of morpholine fungicides using the tris(2,2′-bipyridine) ruthenium(II) chemiluminescence reaction
    Gonzalez, JM
    Greenway, GM
    McCreedy, T
    Qijun, S
    ANALYST, 2000, 125 (04) : 765 - 769
  • [6] Chemiluminescence determination of tetracyclines using a tris(2,2′-bipyridine)ruthenium(II) and potassium permanganate system
    Han, HY
    He, ZK
    Zeng, Y
    ANALYTICAL SCIENCES, 1999, 15 (05) : 467 - 470
  • [7] Chemiluminescence Determination of Tetracyclines Using a Tris(2,2′-bipyridine)ruthenium(II) and Potassium Permanganate System
    Heyou Han
    Zhike He
    Yun’e Zeng
    Analytical Sciences, 1999, 15 : 467 - 470
  • [8] Highly Sensitive Detection of the Insecticide Azamethiphos by Tris(2,2′-bipyridine)ruthenium(II) Electrogenerated Chemiluminescence
    Barkae, Tesfaye Hailemariam
    Zeid, Abdallah M.
    Xu, Guobao
    SENSORS, 2022, 22 (07)
  • [9] Determination of psilocin and psilocybin using flow injection analysis with acidic potassium permanganate and tris(2,2′-bipyridyl) ruthenium(II) chemiluminescence detection respectively
    Anastos, N
    Barnett, NW
    Lewis, SW
    Gathergood, N
    Scammells, PJ
    Sims, DN
    TALANTA, 2005, 67 (02) : 354 - 359
  • [10] Determination of free hydroxyproline and proline in serum by HPLC with electrogenerated chemiluminescence detection using tris(2,2′-bipyridine)ruthenium(II)
    Uchikura, K
    Sakurada, K
    Tezuka, K
    Koike, K
    BUNSEKI KAGAKU, 2002, 51 (10) : 953 - 957